Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Preconcentration of Chromium(VI) at Trace Levels Using Acid Alumina Resin with Column Method

Indonesian Journal of Chemistry · Vol. 14 No. 1 (2014) · hlm. 51–56

DOI
10.22146/ijc.21267
ISSN
1411-9420, 2460-1578
Terbit
2014-03-01
Penerbit
Gadjah Mada University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

Trace analysis of Chromium(VI) ions using acid alumina resin as a filler material column in preconcentration system by off-line method has been carried out. Alumina resin was activated with H2SO4 at pH 1 before being filled to the column. This research showed retention capacity of alumina acid resin was 3.955 mg Cr(VI)/g resin. The analytical performance of this method is good, shown with the limit of detection value was 3.648 µg/L. The reproducibility of this method shown as percentage of coefficient variance was 2.06%. Acid alumina used as resin filler column can increase the signal up to 15.36 times for direct Cr(VI) ions measurement. The accuracy of this method is very good with the recovery percentage value > 95%, shown the matrices of water samples didn’t effect the results of measurements and this method was capable to analyze Cr(VI) ions in water samples at the trace levels.

Kata kunci

Jaringan kolaborasi para penulis

10 penulis · 20 tautan kepenulisan bersama · 7 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Mulawarman University
  • Bandung Institute of Technology
  • State University of Malang
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Sujito SujitoState University of Malang2
Teguh WirawanMulawarman University2
Wirdhaningsih WirdhaningsihMulawarman University2
Farida KristianaMulawarman University2
Muhammad Bachri AmranBandung Institute of Technology2
Buchari BuchariBandung Institute of Technology2

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Preconcentration of Chromium(VI) at Trace Levels Using Acid Alumina Resin with Column Method</dc:title><dc:creator>Aman Sentosa Panggabean</dc:creator><dc:creator>Subur P. Pasaribu</dc:creator><dc:creator>Bohari Bohari</dc:creator><dc:creator>Nurhasanah Nurhasanah</dc:creator><dc:subject>hexavalent chromium</dc:subject><dc:subject>trace analysis</dc:subject><dc:subject>preconcentration</dc:subject><dc:subject>column preconcentration</dc:subject><dc:subject>sulfuric acid activation</dc:subject><dc:subject>water samples</dc:subject><dc:subject>retention capacity</dc:subject><dc:subject>detection limit</dc:subject><dc:subject>matrix effects</dc:subject><dc:description xml:lang="en">Trace analysis of Chromium(VI) ions using acid alumina resin as a filler material column in preconcentration system by off-line method has been carried out. Alumina resin was activated with H2SO4 at pH 1 before being filled to the column. This research showed retention capacity of alumina acid resin was 3.955 mg Cr(VI)/g resin. The analytical performance of this method is good, shown with the limit of detection value was 3.648 µg/L. The reproducibility of this method shown as percentage of coefficient variance was 2.06%. Acid alumina used as resin filler column can increase the signal up to 15.36 times for direct Cr(VI) ions measurement. The accuracy of this method is very good with the recovery percentage value &gt; 95%, shown the matrices of water samples didn’t effect the results of measurements and this method was capable to analyze Cr(VI) ions in water samples at the trace levels.</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2014-03-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://doi.org/10.22146/ijc.21267</dc:identifier><dc:identifier>10.22146/ijc.21267</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 14 No 1 (2014); 51-56</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>