Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Validation of Analytical Method for Vitamin A in Bioadhesive Ocular Cationic Nanoemulsion Loaded into Thermosensitive Gel Using RP-HPLC

Indonesian Journal of Chemistry · Vol. 24 No. 5 (2024) · hlm. 1349–1349

DOI
10.22146/ijc.93395
ISSN
1411-9420, 2460-1578
Terbit
2024-10-01
Penerbit
Gadjah Mada University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

Various test methods have been previously documented for determining vitamin A levels in different dosage forms. This study specifically examines an isocratic reverse phase-high performance liquid chromatography (RP-HPLC) method designed for the direct extraction of vitamin A. The objective is to validate an analytical method for quantifying vitamin A in bioadhesive cationic nanoemulsions incorporated into thermosensitive gels. The method employs isocratic RP-HPLC with a YMC-Triart C18 column (L1), dimensions of 4.6 mm × 250 nm, particle size of S-5 µm, and a UV detector at λ = 265 nm. The mobile phase consists of HPLC-grade methanol, acetonitrile, and n-hexane in a ratio of 46.5:46.5:7. Validation parameters were assessed including selectivity, linearity, accuracy, precision, limit of quantification (LOQ), and limit of detection (LOD). Correlation coefficients were determined with an R2 value of 0.9995 in the concentration range of 264–396 μg/mL (w/v). Recovery percentages ranged from 99.295% to 99.878%. Repeatability and intermediate precision relative standard deviations (RSD) were found to be 0.318% and 0.254%, respectively. The LOD was established at 2.018 μg/mL, and the LOQ was determined to be 6.114 μg/mL. The results affirm cost-effective and well-suited for the accurate measurement of vitamin A levels in bioadhesive thermosensitive gel formulations.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 96 tautan kepenulisan bersama · 14 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Gadjah Mada
  • Universitas Ahmad Dahlan
  • Sultan Agung Islamic University
  • Udayana University
  • University of Würzburg
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Agung Endro NugrohoUniversitas Gadjah Mada5
Arief NurrochmadUniversitas Gadjah Mada2
Dwi Aris Agung NugrahaningsihUniversitas Gadjah Mada2
Su. SismindariUniversitas Gadjah Mada1
Anggun FeranisaSultan Agung Islamic University1
Dewa Ayu ArimurniUniversitas Gadjah Mada1
Hilda IsmailUniversitas Gadjah Mada1
Jajah FachirohUniversitas Gadjah Mada1
Dewa Ayu SwastiniUdayana University1
Agung Endro NugrohoUniversitas Gadjah Mada1
Muhammad KhafiUniversitas Gadjah Mada1
Komang Dian Aditya PutraUniversitas Gadjah Mada1
Devyanto Hadi TriutomoUniversitas Gadjah Mada1
Amalia MirandaUniversitas Gadjah Mada1
Lora Johana TambaUniversitas Gadjah Mada1
Ulrike HolzgrabeUniversity of Würzburg1
Argandita MeiftasariUniversitas Gadjah Mada1
Khairunissa IrnandaUniversitas Gadjah Mada1
Standie NagadiUniversitas Gadjah Mada1
Ratih Kurnia WardaniUniversitas Gadjah Mada1
Lucky Octavianus SaputraUniversitas Gadjah Mada1
Salsabila Yusfita FawzyUniversitas Gadjah Mada1
Masagus Muhammad Prima PutraUniversitas Gadjah Mada1
Indun Dewi PuspitaUniversitas Gadjah Mada1
Winnen WisnumurtiUniversitas Gadjah Mada1
Siti Nurul HidayahUniversitas Gadjah Mada1
Prajona MarbunAfiliasi tidak diketahui1
Annik MegawatiUniversitas Gadjah Mada1
Annas BinarjoUniversitas Ahmad Dahlan1
Rizkita R. EsyantiAfiliasi tidak diketahui1
Nadya FarahAfiliasi tidak diketahui1
Brahmani D. BajraAfiliasi tidak diketahui1
Diah NofitasariAfiliasi tidak diketahui1
Sunardi SunardiAfiliasi tidak diketahui1
Ramadhani SafitriAfiliasi tidak diketahui1
Ragil S. DianingatiAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Validation of Analytical Method for Vitamin A in Bioadhesive Ocular Cationic Nanoemulsion Loaded into Thermosensitive Gel Using RP-HPLC</dc:title><dc:creator>Siti Fatmawati Fatimah</dc:creator><dc:creator>Endang Lukitaningsih</dc:creator><dc:creator>Ronny Martien</dc:creator><dc:creator>Akhmad Kharis Nugroho</dc:creator><dc:subject>vitamin A</dc:subject><dc:subject>analytical method validation</dc:subject><dc:subject>reversed-phase HPLC</dc:subject><dc:subject>cationic nanoemulsions</dc:subject><dc:subject>thermosensitive hydrogel</dc:subject><dc:description xml:lang="en">Various test methods have been previously documented for determining vitamin A levels in different dosage forms. This study specifically examines an isocratic reverse phase-high performance liquid chromatography (RP-HPLC) method designed for the direct extraction of vitamin A. The objective is to validate an analytical method for quantifying vitamin A in bioadhesive cationic nanoemulsions incorporated into thermosensitive gels. The method employs isocratic RP-HPLC with a YMC-Triart C18 column (L1), dimensions of 4.6 mm × 250 nm, particle size of S-5 µm, and a UV detector at λ = 265 nm. The mobile phase consists of HPLC-grade methanol, acetonitrile, and n-hexane in a ratio of 46.5:46.5:7. Validation parameters were assessed including selectivity, linearity, accuracy, precision, limit of quantification (LOQ), and limit of detection (LOD). Correlation coefficients were determined with an R2 value of 0.9995 in the concentration range of 264–396 μg/mL (w/v). Recovery percentages ranged from 99.295% to 99.878%. Repeatability and intermediate precision relative standard deviations (RSD) were found to be 0.318% and 0.254%, respectively. The LOD was established at 2.018 μg/mL, and the LOQ was determined to be 6.114 μg/mL. The results affirm cost-effective and well-suited for the accurate measurement of vitamin A levels in bioadhesive thermosensitive gel formulations.</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2024-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.22146/ijc.93395</dc:identifier><dc:identifier>10.22146/ijc.93395</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 24 No 5 (2024); 1349-1349</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:relation>https://jurnal.ugm.ac.id/ijc/article/download/93395/39423</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>