Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Bioanalytical Method Validation of Metformin Hydrochloride in Human Plasma by HPLC-UV for Preliminary Population-Based Pharmacokinetic Modeling Study

Indonesian Journal of Chemistry · Vol. 23 No. 4 (2023) · hlm. 937–937

DOI
10.22146/ijc.77903
ISSN
1411-9420, 2460-1578
Terbit
2023-08-15
Penerbit
Gadjah Mada University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

This study aims to validate the method for measuring metformin hydrochloride plasma concentrations using High-Performance Liquid Chromatography (HPLC). This research performed chromatography on a 250 mm 4.6 mm 5 µm purosphere® Star RP-18 column at ambient temperature with a UV detector system at 233 nm. The mobile phase components were 70% phosphate buffer (KH2PO4) (10 mM), sodium dodecyl sulfate (0.3 mM), and 30% acetonitrile. It was pumped at an isocratic flow rate of 1.2 mL/min. Metformin HCl and ranitidine HCl (internal standard) were extracted using acetonitrile. The calibration curve was linear (R2 = 0.9998) in the 0.18–6 µg/mL concentration range. The lower limit of quantification (LLOQ) was 0.18 µg/mL. For intraday accuracy and precision, the percent difference and the coefficient of variation were less than 4 and 7%, and for inter-day were lower than 8 and 6%. The recovery average was 100.96%. The short-term plasma stability test was stable at 24 h at ambient temperature, and the long-term stability test was steady for 30 d at −20 °C. It was also stable after three freeze-thaw cycles. The method meets selectivity, sensitivity, linearity, accuracy, precision, recovery, carryover, and stability requirements and can be applied to population-based pharmacokinetic modeling.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 103 tautan kepenulisan bersama · 38 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Gadjah Mada
  • UIN Raden Mas Said Surakarta
  • Islamic University of Indonesia
  • Indonesian Coffee and Cocoa Research Institute
  • Universitas Pattimura
  • Indonesian Institute of Sciences
  • Walailak University
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Ruslin HadanuUniversitas Pattimura5
Jumina JuminaUniversitas Gadjah Mada5
Eti Nurwening SholikhahUniversitas Gadjah Mada5
Iqmal TahirUniversitas Gadjah Mada4
Sabirin MatsjehUniversitas Gadjah Mada4
Jumina JuminaUniversitas Gadjah Mada3
Tutik Dwi WahyuningsihUniversitas Gadjah Mada3
Sabirin MastjehUniversitas Gadjah Mada3
Chairil AnwarUniversitas Gadjah Mada3
Agus Budi SetiawanUniversitas Gadjah Mada2
Ahmad Hamim SadewaUniversitas Gadjah Mada2
Hevi WihadmadyatamiUniversitas Gadjah Mada2
Dwi Liliek KusindartaUniversitas Gadjah Mada2
Widya Pintaka Bayu PutraIndonesian Institute of Sciences2
Pijug SummpunnWalailak University2
Endang LukitaningsihUniversitas Gadjah Mada2
Mahardika Agus WijayantiUniversitas Gadjah Mada2
Elfi Susanti VHSebelas Maret University2
Andi Hairil AlimuddinUniversitas Gadjah Mada2
Ronny MartienUniversitas Gadjah Mada2
Tsalatsatun Nur HidayahUIN Raden Mas Said Surakarta1
Adillah Khairun Nisa’UIN Raden Mas Said Surakarta1
Christantie EffendyUniversitas Gadjah Mada1
Andina SetyawatiHasanuddin University1
Mae Sri Hartati WahyuningsihUniversitas Gadjah Mada1
Sam Chidi IbenemeUniversity of Nigeria1
Michael Hagana BangunAfiliasi tidak diketahui1
Aziz PurwantoroUniversitas Gadjah Mada1
Widya AsmaraUniversitas Gadjah Mada1
Jaka WidadaUniversitas Gadjah Mada1
Alimuddin AlimuddinIPB University1
Reni NurjasmiAfiliasi tidak diketahui1
EM SutrisnaMuhammadiyah University of Surakarta1
Iwan DwiprahastoUniversitas Gadjah Mada1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Bioanalytical Method Validation of Metformin Hydrochloride in Human Plasma by HPLC-UV for Preliminary Population-Based Pharmacokinetic Modeling Study</dc:title><dc:creator>Dimas Adhi Pradana</dc:creator><dc:creator>Erna Kristin</dc:creator><dc:creator>Akhmad Kharis Nugroho</dc:creator><dc:creator>Dwi Aris Agung Nugrahaningsih</dc:creator><dc:creator>Mustofa Mustofa</dc:creator><dc:creator>Ari Wibowo</dc:creator><dc:subject>metformin hydrochloride</dc:subject><dc:subject>bioanalytical method validation</dc:subject><dc:subject>human plasma</dc:subject><dc:subject>HPLC-UV</dc:subject><dc:subject>population pharmacokinetics</dc:subject><dc:subject>method stability</dc:subject><dc:description xml:lang="en">This study aims to validate the method for measuring metformin hydrochloride plasma concentrations using High-Performance Liquid Chromatography (HPLC). This research performed chromatography on a 250 mm 4.6 mm 5 µm purosphere® Star RP-18 column at ambient temperature with a UV detector system at 233 nm. The mobile phase components were 70% phosphate buffer (KH2PO4) (10 mM), sodium dodecyl sulfate (0.3 mM), and 30% acetonitrile. It was pumped at an isocratic flow rate of 1.2 mL/min. Metformin HCl and ranitidine HCl (internal standard) were extracted using acetonitrile. The calibration curve was linear (R2 = 0.9998) in the 0.18–6 µg/mL concentration range. The lower limit of quantification (LLOQ) was 0.18 µg/mL. For intraday accuracy and precision, the percent difference and the coefficient of variation were less than 4 and 7%, and for inter-day were lower than 8 and 6%. The recovery average was 100.96%. The short-term plasma stability test was stable at 24 h at ambient temperature, and the long-term stability test was steady for 30 d at −20 °C. It was also stable after three freeze-thaw cycles. The method meets selectivity, sensitivity, linearity, accuracy, precision, recovery, carryover, and stability requirements and can be applied to population-based pharmacokinetic modeling.</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2023-08-15</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.22146/ijc.77903</dc:identifier><dc:identifier>10.22146/ijc.77903</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 23 No 4 (2023); 937-937</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:relation>https://jurnal.ugm.ac.id/ijc/article/download/77903/36842</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>