Carbon Paste Electrode-Modified Imprinted Zeolite X and Its Performance as a Potentiometric and Voltammetric Sensor for Cholesterol Analysis

Indonesian Journal of Chemistry · Vol. 25 No. 2 (2025) · hlm. 482–482

DOI
10.22146/ijc.99700
ISSN
1411-9420, 2460-1578
Terbit
2025-03-25
Penerbit
Gadjah Mada University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

Carbon paste electrode-modified imprinted zeolite X has been developed as a potentiometry and voltammetry sensor to monitor cholesterol levels in the body. This is crucial to detect early health risks caused by high cholesterol levels. The modified electrode was fabricated with a mass ratio of activated carbon, paraffin, and imprinted zeolite X of 12:7:1. Potentiometric measurement produced a linear dynamic range of 10−6–10−3 M, Nernst factor of 27.12 mV/decade, a detection limit of 1.12 × 10−6 M, precision of 99.7% (n = 3), and accuracy of 99.8% (n = 5). Using the electrode for up to 56 measurements over 6 weeks did not significantly decrease its performance. The presence of glucose did not interfere with cholesterol analysis by potentiometry. The modified electrode was applied to analyze cholesterol voltammetrically at the optimum deposition potential of 0.4 V, deposition time of 60 s, and a scan rate of 100 mV/s. Voltammetric analysis of cholesterol resulted in a detection limit of 7.2 mg/L (1.86 µM), precision of 96–99%, accuracy of 74–114%, sensitivity of 7.1 nA.L/mg/cm2, and recovery of 87.2% (n = 3). The glucose and urea in various concentrations cause less than 5% current deviations.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 128 tautan kepenulisan bersama · 32 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Airlangga
  • Universitas Gadjah Mada
  • Diponegoro University
  • Institut Teknologi Sepuluh Nopember
  • Universiti Sains Malaysia
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Muji HarsiniUniversitas Airlangga4
Gunawan GunawanDiponegoro University2
Muhammad Cholid DjunaidiDiponegoro University2
Zeni RahmawatiInstitut Teknologi Sepuluh Nopember2
Wan Nazwanie Wan AbdullahUniversiti Sains Malaysia2
Usreg Sri HandajaniUniversitas Airlangga2
Bahrotul IlmiahUniversitas Airlangga2
Irene Dinda OktaviaUniversitas Airlangga2
Didik PrasetyokoInstitut Teknologi Sepuluh Nopember1
Hartati HartatiUniversitas Airlangga1
Tanti Kartika DewiUniversitas Airlangga1
Retno Ariadi LusianaDiponegoro University1
Lutfia CahyaningrumDiponegoro University1
Mudasir MudasirUniversitas Gadjah Mada1
Agus KuncakaUniversitas Gadjah Mada1
Eko SugihartoUniversitas Gadjah Mada1
Ganden SupriyantoUniversitas Airlangga1
Siti WafirohUniversitas Airlangga1
Eko Sri KunartiUniversitas Gadjah Mada1
Indriana KartiniUniversitas Gadjah Mada1
Bambang RusdiarsoUniversitas Gadjah Mada1
Nuryono NuryonoUniversitas Gadjah Mada1
Dessy Puspa AryantiUniversitas Gadjah Mada1
Madjid Arie WibowoUniversitas Gadjah Mada1
Mei Dian Risda AfrianiDiponegoro University1
Aisyah AisyahUniversitas Airlangga1
Andina Fitriyah SalsabilahUniversitas Airlangga1
Abdulloh AbdullohUniversitas Airlangga1
Satya Candra Wibawa SaktiUniversitas Airlangga1
Ulfa RahmahUniversitas Airlangga1
Ahmadi Jaya PermanaUniversitas Airlangga1
Rochadi PrasetyaUniversitas Airlangga1
Musbahu Adam AhmadUniversitas Airlangga1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Carbon Paste Electrode-Modified Imprinted Zeolite X and Its Performance as a Potentiometric and Voltammetric Sensor for Cholesterol Analysis</dc:title><dc:creator>Miratul Khasanah</dc:creator><dc:creator>Alfa Akustia Widati</dc:creator><dc:creator>Nadya Maya Severia</dc:creator><dc:creator>Citra Marantika Nur Oktaviana</dc:creator><dc:creator>Evrillia Puspitasari</dc:creator><dc:creator>Naftalia Wirdatul Ummah</dc:creator><dc:creator>Ziana Alviani</dc:creator><dc:subject>cholesterol detection</dc:subject><dc:subject>carbon paste electrode</dc:subject><dc:subject>potentiometric sensors</dc:subject><dc:subject>voltammetric sensor</dc:subject><dc:subject>modified electrode</dc:subject><dc:subject>cholesterol biosensor</dc:subject><dc:subject>electrochemical sensor</dc:subject><dc:subject>glucose interference</dc:subject><dc:subject>urea interference</dc:subject><dc:description xml:lang="en">Carbon paste electrode-modified imprinted zeolite X has been developed as a potentiometry and voltammetry sensor to monitor cholesterol levels in the body. This is crucial to detect early health risks caused by high cholesterol levels. The modified electrode was fabricated with a mass ratio of activated carbon, paraffin, and imprinted zeolite X of 12:7:1. Potentiometric measurement produced a linear dynamic range of 10−6–10−3 M, Nernst factor of 27.12 mV/decade, a detection limit of 1.12 × 10−6 M, precision of 99.7% (n = 3), and accuracy of 99.8% (n = 5). Using the electrode for up to 56 measurements over 6 weeks did not significantly decrease its performance. The presence of glucose did not interfere with cholesterol analysis by potentiometry. The modified electrode was applied to analyze cholesterol voltammetrically at the optimum deposition potential of 0.4 V, deposition time of 60 s, and a scan rate of 100 mV/s. Voltammetric analysis of cholesterol resulted in a detection limit of 7.2 mg/L (1.86 µM), precision of 96–99%, accuracy of 74–114%, sensitivity of 7.1 nA.L/mg/cm2, and recovery of 87.2% (n = 3). The glucose and urea in various concentrations cause less than 5% current deviations.</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2025-03-25</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.22146/ijc.99700</dc:identifier><dc:identifier>10.22146/ijc.99700</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 25 No 2 (2025); 482-482</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:relation>https://journal.ugm.ac.id/ijc/article/download/99700/41107</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>