Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Analysis of Hg(II) Metal by Voltammetric Method Using a Carbon Electrode Modified with EDTA from Used Tire Waste

Indonesian Journal of Chemistry · Vol. 24 No. 6 (2024) · hlm. 1824–1824

DOI
10.22146/ijc.97561
ISSN
1411-9420, 2460-1578
Terbit
2024-12-01
Penerbit
Gadjah Mada University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

Development of a carbon electrode sensor from used tire waste via pyrolysis, modified with ethylenediaminetetraacetic acid (EDTA) for mercury detection using the cyclic voltammetry (CV) method. EDTA plays a role in metal complexation due to its strong response to mercury metal. The FTIR results of the carbon electrode and EDTA show a C–N bond at a wavenumber of 1,217.08 cm−1, indicating the presence of EDTA. The SEM results reveal a clear difference between the unmodified carbon electrode and the EDTA-modified carbon electrode. The calibration graph is linear, with an R2 value of 0.9961, a sensitivity of 0.3472, as well as LoD and LoQ values of 0.03 and 0.08 ppm, respectively. The correlation coefficient is less than 2%, and the %recovery is within the allowable error range. Mercury measurements in Sungai Mas water samples, Aceh Barat, using voltammetry and AAS, exceed the threshold set by Indonesian Government Regulation (PPRI) No. 22 of 2021. The t-test results for the two Hg measurement methods at a 5% significance level (α) show that tcalculated < ttable (0.083 < 2.571). This indicates no significant difference between the voltammetry and AAS methods for measuring Hg concentrations in water.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 143 tautan kepenulisan bersama · 57 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Syiah Kuala
  • Mercu Buana University
  • National University of Malaysia
  • Universitas Gajah Putih
  • National Research and Innovation Agency
  • MIMOS (Malaysia)
  • Akademi Kebidanan Bunga Husada
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Baihaqi BaihaqiUniversitas Syiah Kuala4
Syafrizal FonnaAfiliasi tidak diketahui4
Binawati GintingUniversitas Syiah Kuala4
Ahmad Kamal ArifinNational University of Malaysia4
Cut HusnaUniversitas Syiah Kuala2
Hajjul KamilUniversitas Syiah Kuala2
Teuku TahlilUniversitas Syiah Kuala2
Aiman Sajidah Abd AzizMIMOS (Malaysia)2
Fauziah FauziahAkademi Kebidanan Bunga Husada1
Widya Puspita SariUniversitas Syiah Kuala1
Fajar DiniUniversitas Syiah Kuala1
Nanda KhirnaUniversitas Syiah Kuala1
ULIL HASRI DESFIANAUniversitas Syiah Kuala1
Sulastri SulastriUniversitas Syiah Kuala1
Abdul HalimInstitut Agama Islam Negeri Kendari1
Teuku Muhammad Hary RamadhanUniversitas Syiah Kuala1
S SafridaUniversitas Syiah Kuala1
Agnia PurnamaUniversitas Syiah Kuala1
B A GintingUniversitas Syiah Kuala1
Muhammad Ridho AfifiUniversitas Syiah Kuala1
Ruhul MaghfirahUniversitas Syiah Kuala1
Mutia FaridaUniversitas Syiah Kuala1
Hamdiyati HamdiyatiUniversitas Syiah Kuala1
Darmawati DarmawatiUniversitas Syiah Kuala1
Ahmad AririMercu Buana University1
Siti Aishah HasbullahNational University of Malaysia1
Rita SundariMercu Buana University1
Mas’ud AsadullahMercu Buana University1
Ali RinaldiKing Fahd University of Petroleum and Minerals1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Analysis of Hg(II) Metal by Voltammetric Method Using a Carbon Electrode Modified with EDTA from Used Tire Waste</dc:title><dc:creator>Sukoma Sukoma</dc:creator><dc:creator>Sagir Alva</dc:creator><dc:creator>Eka Safitri</dc:creator><dc:creator>Julinawati Julinawati</dc:creator><dc:creator>Mustanir Yahya</dc:creator><dc:creator>Syarizal Fonna</dc:creator><dc:creator>Muhammad Ihsan</dc:creator><dc:creator>Fitri Dara</dc:creator><dc:creator>Meri Dayanti</dc:creator><dc:creator>Ahmad Kamal Ariffin</dc:creator><dc:creator>Khairi Suhud</dc:creator><dc:subject>mercury detection</dc:subject><dc:subject>carbon electrodes</dc:subject><dc:subject>pyrolysis</dc:subject><dc:subject>mercury complexation</dc:subject><dc:subject>mercury in water</dc:subject><dc:subject>electrochemical sensor</dc:subject><dc:description xml:lang="en">Development of a carbon electrode sensor from used tire waste via pyrolysis, modified with ethylenediaminetetraacetic acid (EDTA) for mercury detection using the cyclic voltammetry (CV) method. EDTA plays a role in metal complexation due to its strong response to mercury metal. The FTIR results of the carbon electrode and EDTA show a C–N bond at a wavenumber of 1,217.08 cm−1, indicating the presence of EDTA. The SEM results reveal a clear difference between the unmodified carbon electrode and the EDTA-modified carbon electrode. The calibration graph is linear, with an R2 value of 0.9961, a sensitivity of 0.3472, as well as LoD and LoQ values of 0.03 and 0.08 ppm, respectively. The correlation coefficient is less than 2%, and the %recovery is within the allowable error range. Mercury measurements in Sungai Mas water samples, Aceh Barat, using voltammetry and AAS, exceed the threshold set by Indonesian Government Regulation (PPRI) No. 22 of 2021. The t-test results for the two Hg measurement methods at a 5% significance level (α) show that tcalculated &lt; ttable (0.083 &lt; 2.571). This indicates no significant difference between the voltammetry and AAS methods for measuring Hg concentrations in water.</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2024-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>http://dx.doi.org/10.22146/ijc.97561</dc:identifier><dc:identifier>10.22146/ijc.97561</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 24 No 6 (2024); 1824-1824</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:relation>https://jurnal.ugm.ac.id/ijc/article/download/97561/40134</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>