Akses terbuka
Jurnal
SINTA 1
The Utilization of Nitrogen Gas as a Carrier Gas in the Determination of Hg Ions Using Cold Vapor-Atomic Absorption Spectrophotometer (CV-AAS)
Indonesian Journal of Chemistry · Vol. 18 No. 2 (2018) · hlm. 279–279
ISSN 1411-9420, 2460-1578
Terbit 2018-05-30
Penerbit Gadjah Mada University
Bahasa en
Abstrak
The research about utilization of nitrogen gas as a carrier gas in the determination of Hg ions by using Cold Vapor-Atomic Absorption Spectrophotometer (CV-AAS) method has been conducted. To optimize the measurement results, several parameters that affect hydride generator have been studied. Some specified important parameters are SnCl2 concentration as reductant, acid concentration, and the analytical performance such as repeatability and reproducibility (% RSD), linearity (r), limits of detection (LOD) and limits of quantitation (LOQ), and accuracy have been studied. The results of the research showed that the nitrogen gas can be used instead of argon gas as a carrier gas. It was shown by the repeatability values as % RSD < 2/3 CV Horwitz values, the LOD was 0.0338 µg/L and the LOQ was 0.0838 µg/L. The accuracy of this method was well shown by a recovery percentage was 102.24%. Based on the result of this research, the nitrogen gas can be used as a carrier gas for the determination of Hg ions by using the CV-AAS method with valid results.
Jaringan kolaborasi para penulis
10 penulis ·
20 tautan kepenulisan bersama
· 7 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Mulawarman University Bandung Institute of Technology State University of Malang
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">The Utilization of Nitrogen Gas as a Carrier Gas in the Determination of Hg Ions Using Cold Vapor-Atomic Absorption Spectrophotometer (CV-AAS)</dc:title><dc:creator>Aman Sentosa Panggabean</dc:creator><dc:creator>Subur P. Pasaribu</dc:creator><dc:creator>Farida Kristiana</dc:creator><dc:subject>mercury determination</dc:subject><dc:subject>nitrogen carrier gas</dc:subject><dc:subject>hydride generator</dc:subject><dc:subject>tin(II) chloride reduction</dc:subject><dc:subject>detection limit</dc:subject><dc:description xml:lang="en">The research about utilization of nitrogen gas as a carrier gas in the determination of Hg ions by using Cold Vapor-Atomic Absorption Spectrophotometer (CV-AAS) method has been conducted. To optimize the measurement results, several parameters that affect hydride generator have been studied. Some specified important parameters are SnCl2 concentration as reductant, acid concentration, and the analytical performance such as repeatability and reproducibility (% RSD), linearity (r), limits of detection (LOD) and limits of quantitation (LOQ), and accuracy have been studied. The results of the research showed that the nitrogen gas can be used instead of argon gas as a carrier gas. It was shown by the repeatability values as % RSD < 2/3 CV Horwitz values, the LOD was 0.0338 µg/L and the LOQ was 0.0838 µg/L. The accuracy of this method was well shown by a recovery percentage was 102.24%. Based on the result of this research, the nitrogen gas can be used as a carrier gas for the determination of Hg ions by using the CV-AAS method with valid results.</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2018-05-30</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.22146/ijc.23092</dc:identifier><dc:identifier>10.22146/ijc.23092</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 18 No 2 (2018); 279-279</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:relation>https://jurnal.ugm.ac.id/ijc/article/download/23092/19551</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Terindeks
lewat ID karya OpenAlex (record dari sumber OpenAlex)
19 sitasi
Crossref
Terindeks
lewat DOI
4 sitasi
Jumlah menurut tiap indeks pada 19 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref, doaj.
Sitasi artikel ini
APA 7
Panggabean, A. S., Pasaribu, S. P., & Kristiana, F. (2018). The Utilization of Nitrogen Gas as a Carrier Gas in the Determination of Hg Ions Using Cold Vapor-Atomic Absorption Spectrophotometer (CV-AAS). Indonesian Journal of Chemistry, 18(2), 279–279. https://doi.org/10.22146/ijc.23092
Salin
IEEE
A. S. Panggabean, S. P. Pasaribu, and F. Kristiana, “The Utilization of Nitrogen Gas as a Carrier Gas in the Determination of Hg Ions Using Cold Vapor-Atomic Absorption Spectrophotometer (CV-AAS),” Indonesian Journal of Chemistry, vol. 18, no. 2, pp. 279–279, 2018, doi: 10.22146/ijc.23092.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.