ENHANCEMENT OF THE SENSITIVITY AND SELECTIVITY OF THE VOLTAMMETRIC SENSOR FOR URIC ACID USING MOLECULARLY IMPRINTED POLYMER

Indonesian Journal of Chemistry · Vol. 10 No. 3 (2010) · hlm. 295–300

DOI
10.22146/ijc.21433
ISSN
1411-9420, 2460-1578
Terbit
2010-12-14
Penerbit
Gadjah Mada University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

The sensitivity and selectivity of voltammetric sensor for uric acid can be improved by modifying the working electrode using a polymer with a molecular template (molecularly imprinted polymer, MIP). Polymer and MIP was synthesized from methacrylic acid (MAA) as monomer, ethylene glycol dimethacrylic acid (EGDMA) as cross-linker, uric acid (UA) as template and the results were characterized by various methods. The poly-MAA formation was identified by a decrease in the intensity of infrared (IR) spectra at ~1540 cm-1 (C=C) and an increase at ~1700 cm-1 (C=O) compared to the IR spectra of the MAA and EGDMA. The SEM analysis showed that the cavity of polymer is small enough (~ 0.1 µm) and homogeneous. Establishment of MIP was carried out by extracting of the uric acid from the polymer network. The IR spectra of MIP exhibited the decrease in intensity at ~1700 cm-1 (C=O) compared to the non imprinted polymer (NIP). The data of BET analysis showed that polymer pore size increase slightly from 37.71 Å to 38.02 Å after the extraction process of uric acid from the polymer network. Its may be due to incomplete extraction of uric acid from the polymer network. Modifications of hanging mercury drop electrode using MIP made from MAA, EGDMA, and UA with a mole ratio of 1:3:1 produced a sensitive and selective voltammetric sensor for uric acid. The sensitivity obtained was 16.405 nA L/µg. The presence of ascorbic acid in equal concentration with uric acid decreased the current response of only 0.08%. Compared to HMDE electrode, the sensitivity and selectivity of the HMDE-MIP sensor enhanced about 100 and 700 times, respectively. The detection limit was found to be 5.94 x10-10 M.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 117 tautan kepenulisan bersama · 42 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Gadjah Mada
  • Universitas Airlangga
  • Diponegoro University
  • Yogyakarta State University
  • Universitas Islam Negeri Ar-Raniry
  • Islamic University of Indonesia
  • Sebelas Maret University
  • Organisasi lain
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Iqmal TahirUniversitas Gadjah Mada6
Adhitasari SuratmanUniversitas Gadjah Mada5
Dwi SiswantaUniversitas Gadjah Mada5
Karna WijayaUniversitas Gadjah Mada4
Roto RotoUniversitas Gadjah Mada4
Ngatidjo HadipranotoUniversitas Gadjah Mada4
Suyanta SuyantaUniversitas Gadjah Mada3
Alfa Akustia WidatiUniversitas Airlangga3
Harno Dwi PranowoUniversitas Gadjah Mada3
Endang Tri WahyuniUniversitas Gadjah Mada3
Wega TrisunaryantiUniversitas Gadjah Mada3
Triyono TriyonoUniversitas Gadjah Mada3
Karna WijayaUniversitas Gadjah Mada3
Anjar Purba AsmaraUniversitas Islam Negeri Ar-Raniry2
Is FatimahIslamic University of Indonesia2
Nuryono NuryonoUniversitas Gadjah Mada2
Hanim Istatik Badi’ahUniversitas Airlangga2
Ni Nyoman Tri PuspaningsihUniversitas Airlangga2
Gunawan GunawanDiponegoro University2
Muhammad Cholid DjunaidiDiponegoro University2
Muji HarsiniUniversitas Airlangga2
Hasri HasriState University of Makassar2
Mudjiran MudjiranUniversitas Gadjah Mada2
Choirul AmriPoltekkes Kemenkes Yogyakarta2
Crys Fajar PartanaYogyakarta State University2
Cahyorini KusumawardaniYogyakarta State University2
Sri HastutiSebelas Maret University2
Prastika Krisma JiwantiUniversitas Airlangga2
Yasuaki EinagaKeio University2
Pratiwi PudjiastutiUniversitas Airlangga2
Agus Dwi AnantoUniversity of Mataram1
Ria ArmunantoUniversitas Gadjah Mada1
Ni Made WiratiniUniversitas Pendidikan Ganesha1
Maria MassoraUniversitas Gadjah Mada1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">ENHANCEMENT OF THE SENSITIVITY AND SELECTIVITY OF THE VOLTAMMETRIC SENSOR FOR URIC ACID USING MOLECULARLY IMPRINTED POLYMER</dc:title><dc:creator>Miratul Khasanah</dc:creator><dc:creator>Mudasir Mudasir</dc:creator><dc:creator>Agus Kuncaka</dc:creator><dc:creator>Eko Sugiharto</dc:creator><dc:creator>Ganden Supriyanto</dc:creator><dc:creator>Siti Wafiroh</dc:creator><dc:subject>uric acid</dc:subject><dc:subject>molecularly imprinted polymers</dc:subject><dc:subject>voltammetric sensor</dc:subject><dc:subject>hanging mercury drop electrode</dc:subject><dc:subject>methacrylic acid</dc:subject><dc:subject>template extraction</dc:subject><dc:subject>detection limit</dc:subject><dc:subject>sensitivity and selectivity</dc:subject><dc:subject>ascorbic acid interference</dc:subject><dc:description xml:lang="en">The sensitivity and selectivity of voltammetric sensor for uric acid can be improved by modifying the working electrode using a polymer with a molecular template (molecularly imprinted polymer, MIP). Polymer and MIP was synthesized from methacrylic acid (MAA) as monomer, ethylene glycol dimethacrylic acid (EGDMA) as cross-linker, uric acid (UA) as template and the results were characterized by various methods. The poly-MAA formation was identified by a decrease in the intensity of infrared (IR) spectra at ~1540 cm-1 (C=C) and an increase at ~1700 cm-1 (C=O) compared to the IR spectra of the MAA and EGDMA. The SEM analysis showed that the cavity of polymer is small enough (~ 0.1 µm) and homogeneous. Establishment of MIP was carried out by extracting of the uric acid from the polymer network. The IR spectra of MIP exhibited the decrease in intensity at ~1700 cm-1 (C=O) compared to the non imprinted polymer (NIP). The data of BET analysis showed that polymer pore size increase slightly from 37.71 Å to 38.02 Å after the extraction process of uric acid from the polymer network. Its may be due to incomplete extraction of uric acid from the polymer network. Modifications of hanging mercury drop electrode using MIP made from MAA, EGDMA, and UA with a mole ratio of 1:3:1 produced a sensitive and selective voltammetric sensor for uric acid. The sensitivity obtained was 16.405 nA L/µg. The presence of ascorbic acid in equal concentration with uric acid decreased the current response of only 0.08%. Compared to HMDE electrode, the sensitivity and selectivity of the HMDE-MIP sensor enhanced about 100 and 700 times, respectively. The detection limit was found to be 5.94 x10-10 M.</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2010-12-14</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>http://doi.org/10.22146/ijc.21433</dc:identifier><dc:identifier>10.22146/ijc.21433</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 10 No 3 (2010); 295-300</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>