Akses terbuka Jurnal SINTA 1

A Univariate Optimization Strategy for Pre-concentration of Cobalt(II) in Various Matrixes by a DLLME before Analysis Using FAAS

Indonesian Journal of Chemistry · Vol. 24 No. 2 (2024) · hlm. 403–403

DOI
10.22146/ijc.88218
ISSN
1411-9420, 2460-1578
Terbit
2024-04-01
Penerbit
Gadjah Mada University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

A procedure based on dispersive liquid-liquid microextraction (DLLME) for cobalt (Co) quantification in an Iraqi environmental matrix by flame atomic absorption spectroscopy (FAAS) was applied in this work. A case-study approach was chosen to obtain further in-depth information on the Co levels and to evaluate the effectiveness of N-salicylideneaniline (SAN) as a complexing agent for pre-concentration and extraction of Co. An univariate strategy was utilized to achieve the optimum extraction conditions. The estimated limits of detection (LOD) and quantification (LOQ) under optimum conditions were 1.04 and 3.47 µg L−1, respectively. The results achieved by the proposed system were compared with those using the microwave digestion/graphite furnace atomic absorption spectrometer (MWD/GF-AAS) for digest samples and also for some water samples (Direct GF-AAS). The proposed procedure was applied for analyzing eleven environmental samples. The detectable Co levels for water samples ranged from 0.72 to 4.30 µg L−1 with a relative standard deviation of 3.7–8.8%, while the concentration for solid samples ranged from 0.17–4.51 µg g−1 (2.4–11.8 RSD %). DLLME/FAAS proposed procedure is effective, simple, and has the benefit of minimizing the organic solvent consumption by a few microliters, which results in little waste.

Kata kunci

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama · 1 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Al-Muthanna University
  • Thi Qar University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">A Univariate Optimization Strategy for Pre-concentration of Cobalt(II) in Various Matrixes by a DLLME before Analysis Using FAAS</dc:title><dc:creator>Zaman Sahb Mehdi</dc:creator><dc:creator>Saher A. Ali Alshamkhawy</dc:creator><dc:subject>dispersive liquid-liquid microextraction</dc:subject><dc:subject>N-salicylideneaniline</dc:subject><dc:subject>chelating agents</dc:subject><dc:subject>univariate optimization</dc:subject><dc:subject>flame atomic absorption spectrometry</dc:subject><dc:subject>environmental samples</dc:subject><dc:subject>water samples</dc:subject><dc:subject>solid samples</dc:subject><dc:subject>microwave digestion</dc:subject><dc:subject>graphite furnace atomic absorption spectrometry</dc:subject><dc:subject>solvent reduction</dc:subject><dc:description xml:lang="en">A procedure based on dispersive liquid-liquid microextraction (DLLME) for cobalt (Co) quantification in an Iraqi environmental matrix by flame atomic absorption spectroscopy (FAAS) was applied in this work. A case-study approach was chosen to obtain further in-depth information on the Co levels and to evaluate the effectiveness of N-salicylideneaniline (SAN) as a complexing agent for pre-concentration and extraction of Co. An univariate strategy was utilized to achieve the optimum extraction conditions. The estimated limits of detection (LOD) and quantification (LOQ) under optimum conditions were 1.04 and 3.47 µg L−1, respectively. The results achieved by the proposed system were compared with those using the microwave digestion/graphite furnace atomic absorption spectrometer (MWD/GF-AAS) for digest samples and also for some water samples (Direct GF-AAS). The proposed procedure was applied for analyzing eleven environmental samples. The detectable Co levels for water samples ranged from 0.72 to 4.30 µg L−1 with a relative standard deviation of 3.7–8.8%, while the concentration for solid samples ranged from 0.17–4.51 µg g−1 (2.4–11.8 RSD %). DLLME/FAAS proposed procedure is effective, simple, and has the benefit of minimizing the organic solvent consumption by a few microliters, which results in little waste.</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2024-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.22146/ijc.88218</dc:identifier><dc:identifier>10.22146/ijc.88218</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 24 No 2 (2024); 403-403</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:relation>https://jurnal.ugm.ac.id/ijc/article/download/88218/38139</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>