Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

SIMULTANEOUS DETERMINATION OF PARACETAMOL AND IBUPROFENE MIXTURES BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Indonesian Journal of Chemistry · Vol. 3 No. 1 (2010) · hlm. 9–13

DOI
10.22146/ijc.21899
ISSN
1411-9420, 2460-1578
Terbit
2010-06-07
Penerbit
Gadjah Mada University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

Analytical method for the determination of paracetamol and ibuprofene mixtures has been developed by High Performance Liquid Chromatography using C-18 column and acetinitrile - phosphate buffer pH = 4.5 (75:25) containing 0.075% sodium hexanesulfunate as a mobile phase. The detector was set at 215 nm. Using such conditions, retention time for paracetamol and ibuprofen was 4.89 and 7.11 min, respectively. The recovery for paracetamol and ibuprofen was found to be 101.07± 0.73% and 102.02 ± 1.58%, respectively. The detector limits of the method was 1.30 and 1.60 μg/mL with the relative standard deviation (RSD) 0.74 and 1.52% for paracetamol and ibuprofen, respectively. Keywords: paracetamol, ibuprofen, multi-component, validation, HPLC.

Kata kunci

Jaringan kolaborasi para penulis

34 penulis · 93 tautan kepenulisan bersama · 33 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Bandung Institute of Technology
  • Universitas Halu Oleo
  • University of Indonesia
  • Tadulako University
  • Muhammadiyah University Purwokerto
  • Pakuan University
  • National Nuclear Energy Agency of Indonesia
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Muhammad ArbaUniversitas Halu Oleo4
Ruslin RuslinUniversitas Halu Oleo2
Rahmana Emran KartasasmitaBandung Institute of Technology2
Dian Ayu Eka PitalokaBandung Institute of Technology2
Indra WibowoBandung Institute of Technology2
Rika HartatiBandung Institute of Technology2
Benny PermanaBandung Institute of Technology2
Bina Lohita SariPakuan University2
Muhammad Ali ZulfikarBandung Institute of Technology2
Engrid Juni AstutiBandung Institute of Technology2
Slamet IbrahiimAfiliasi tidak diketahui1
Arry YanuarUniversity of Indonesia1
Muhammad Sulaiman ZubairTadulako University1
Sanang Nur SafitriUniversitas Halu Oleo1
Andry Nur HidayatUniversitas Halu Oleo1
Asmiyenti Djaliasrin DjalilMuhammadiyah University Purwokerto1
Rizky Juwita SugihartiNational Nuclear Energy Agency of Indonesia1
Rani MaharaniPadjadjaran University1
Sukrasno SukrasnoBandung Institute of Technology1
Indra Topik MaulanaBandung Islamic University1
Maulidiyah MaulidiyahUniversitas Halu Oleo1
Nursan NursanUniversitas Halu Oleo1
Malindo SufriadinUniversitas Halu Oleo1
Elin Yulinah SukandarBandung Institute of Technology1
Anita ArtariniBandung Institute of Technology1
Nadiyah Athifah Salim MartakBandung Institute of Technology1
Adi SuwandiBandung Institute of Technology1
Samuel Gunadi TanusondjajaBandung Institute of Technology1
Amir MusadadBandung Institute of Technology1
Septy Mariana KBandung Institute of Technology1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">SIMULTANEOUS DETERMINATION OF PARACETAMOL AND IBUPROFENE MIXTURES BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY</dc:title><dc:creator>Sophi Damayanti</dc:creator><dc:creator>Slamet Ibrahim</dc:creator><dc:creator>Kurnia Firman</dc:creator><dc:creator>Daryono Hadi Tjahjono</dc:creator><dc:subject>paracetamol</dc:subject><dc:subject>ibuprofen</dc:subject><dc:subject>simultaneous determination</dc:subject><dc:subject>drug mixture analysis</dc:subject><dc:subject>HPLC method validation</dc:subject><dc:subject>pharmaceutical analysis</dc:subject><dc:description xml:lang="en">Analytical method for the determination of paracetamol and ibuprofene mixtures has been developed by High Performance Liquid Chromatography using C-18 column and acetinitrile - phosphate buffer pH = 4.5 (75:25) containing 0.075% sodium hexanesulfunate as a mobile phase. The detector was set at 215 nm. Using such conditions, retention time for paracetamol and ibuprofen was 4.89 and 7.11 min, respectively. The recovery for paracetamol and ibuprofen was found to be 101.07± 0.73% and 102.02 ± 1.58%, respectively. The detector limits of the method was 1.30 and 1.60 μg/mL with the relative standard deviation (RSD) 0.74 and 1.52% for paracetamol and ibuprofen, respectively. Keywords: paracetamol, ibuprofen, multi-component, validation, HPLC.</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2010-06-07</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>http://doi.org/10.22146/ijc.21899</dc:identifier><dc:identifier>10.22146/ijc.21899</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 3 No 1 (2010); 9-13</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>