Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Two Rival Newly Fabricated Potentiometric Sensors to Enhance Selectivity Toward Cu(II) Ions

Indonesian Journal of Chemistry · Vol. 21 No. 6 (2021) · hlm. 1491–1491

DOI
10.22146/ijc.66938
ISSN
1411-9420, 2460-1578
Terbit
2021-10-27
Penerbit
Gadjah Mada University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

Utilizing the well-known ability of Schiff base ligands to bind metal ions, two newly fabricated ligands, namely: 2-((2-hydroxybenzylidene)amino)benzoic acid (L1) and 2-(furan-2-ylmethyleneamino)phenol (L2) were employed to coordinate copper(II) (Cu(II)) producing the characteristically stable complexes that performed as the ionophores in the presently fabricated electrodes A and B. Thus it was possible to build these electrodes that have attractive properties and expected behavior, namely, low detection limits: 2.32 × 10–7 and 1.14 × 10–6 M Cu(II), Nernstian slope of 29.13 and 30.85 mV/decade Cu(II), broad concentration ranges from 3.98 × 10–7–1.00 × 10–2 and 1.52 × 10–6–1.00 × 10–2 M for sensors A and B, respectively, as well as short response time (ca. 3–5 s) with distinct selectivity toward Cu(II) over the other cations and applicability over the pH range 1.5–5.5 for miscellaneous samples: aqueous solutions, urine, and blood serum. Thus, these sensors surpass many others towards fulfilling the intended function of Cu(II) determination in various applications.

Kata kunci

Jaringan kolaborasi para penulis

4 penulis · 6 tautan kepenulisan bersama · 5 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • King Saud University
  • Al-Aqsa University
  • Islamic University of Gaza
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Two Rival Newly Fabricated Potentiometric Sensors to Enhance Selectivity Toward Cu(II) Ions</dc:title><dc:creator>Gamal A E Mostafa</dc:creator><dc:creator>Hazem Mohammed Abu Shawish</dc:creator><dc:creator>Salman M. Saadeh</dc:creator><dc:creator>Essam Ezzeldin</dc:creator><dc:subject>copper(II) determination</dc:subject><dc:subject>potentiometric sensors</dc:subject><dc:subject>Schiff base ligands</dc:subject><dc:subject>copper(II) complexes</dc:subject><dc:subject>ionophores</dc:subject><dc:subject>sensor selectivity</dc:subject><dc:subject>urine analysis</dc:subject><dc:subject>serum analysis</dc:subject><dc:subject>Nernstian response</dc:subject><dc:description xml:lang="en">Utilizing the well-known ability of Schiff base ligands to bind metal ions, two newly fabricated ligands, namely: 2-((2-hydroxybenzylidene)amino)benzoic acid (L1) and 2-(furan-2-ylmethyleneamino)phenol (L2) were employed to coordinate copper(II) (Cu(II)) producing the characteristically stable complexes that performed as the ionophores in the presently fabricated electrodes A and B. Thus it was possible to build these electrodes that have attractive properties and expected behavior, namely, low detection limits: 2.32 × 10–7 and 1.14 × 10–6 M Cu(II), Nernstian slope of 29.13 and 30.85 mV/decade Cu(II), broad concentration ranges from 3.98 × 10–7–1.00 × 10–2 and 1.52 × 10–6–1.00 × 10–2 M for sensors A and B, respectively, as well as short response time (ca. 3–5 s) with distinct selectivity toward Cu(II) over the other cations and applicability over the pH range 1.5–5.5 for miscellaneous samples: aqueous solutions, urine, and blood serum. Thus, these sensors surpass many others towards fulfilling the intended function of Cu(II) determination in various applications.</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2021-10-27</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.22146/ijc.66938</dc:identifier><dc:identifier>10.22146/ijc.66938</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 21 No 6 (2021); 1491-1491</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:relation>https://jurnal.ugm.ac.id/ijc/article/download/66938/32336</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>