Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Development of a Point-of-Use Drinking Water Purifier Using Aluminum Oxide-Based Flocculent-Disinfectant Composite

Indonesian Journal of Chemistry · Vol. 23 No. 3 (2023) · hlm. 636–636

DOI
10.22146/ijc.79024
ISSN
1411-9420, 2460-1578
Terbit
2023-05-10
Penerbit
Gadjah Mada University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

One in every three people in the world still lacks access to clean drinking water. Aside from microbiological pollution, high fluoride content in drinking water is one of the most serious problems in African countries. This study aimed to contribute to the availability of clean water by developing a point-of-use drinking water purifier using an aluminum oxide-based flocculent-disinfectant composite. Batch experiments were conducted to determine factors affecting fluoride removal efficiency (FRE) and E. coli log reduction efficiency. AO of 75 mg/L, 800 mg/L alum, lime (35% alum dose), and 1.5 mg/L Ca(OCl)₂ doses achieved 95% FRE and 5 log10 reductions of E. coli using 15 mg/L as initial fluoride concentration ([F−]0), and 105 CFU/100 mL E. coli concentration. [F−]0 affected FRE but showed no effect on E. coli log reduction. The optimum pH of the solution for both FRE and E. coli log reduction was found to be in the range of 4–8. Three prototypes in powder form were developed. The prototypes were tested on real water samples from the Ethiopian Rift Valley, and the results were found to be within the drinking water standards, thus indicating the capability of the developed products to purify contaminated water for human consumption.

Kata kunci

Jaringan kolaborasi para penulis

3 penulis · 3 tautan kepenulisan bersama · 3 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Lilongwe University of Agriculture and Natural Resources
  • Addis Ababa University
  • Bio and Emerging Technology Institute
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Development of a Point-of-Use Drinking Water Purifier Using Aluminum Oxide-Based Flocculent-Disinfectant Composite</dc:title><dc:creator>Patricia Nemate</dc:creator><dc:creator>Feleke Zewge</dc:creator><dc:creator>Eyobel Mulugeta</dc:creator><dc:subject>household water treatment</dc:subject><dc:subject>fluoride removal</dc:subject><dc:subject>alumina</dc:subject><dc:subject>alum</dc:subject><dc:subject>lime</dc:subject><dc:subject>calcium hypochlorite</dc:subject><dc:subject>Escherichia coli inactivation</dc:subject><dc:subject>pH effect</dc:subject><dc:subject>Ethiopian Rift Valley</dc:subject><dc:subject>waterborne diseases</dc:subject><dc:description xml:lang="en">One in every three people in the world still lacks access to clean drinking water. Aside from microbiological pollution, high fluoride content in drinking water is one of the most serious problems in African countries. This study aimed to contribute to the availability of clean water by developing a point-of-use drinking water purifier using an aluminum oxide-based flocculent-disinfectant composite. Batch experiments were conducted to determine factors affecting fluoride removal efficiency (FRE) and E. coli log reduction efficiency. AO of 75 mg/L, 800 mg/L alum, lime (35% alum dose), and 1.5 mg/L Ca(OCl)₂ doses achieved 95% FRE and 5 log10 reductions of E. coli using 15 mg/L as initial fluoride concentration ([F−]0), and 105 CFU/100 mL E. coli concentration. [F−]0 affected FRE but showed no effect on E. coli log reduction. The optimum pH of the solution for both FRE and E. coli log reduction was found to be in the range of 4–8. Three prototypes in powder form were developed. The prototypes were tested on real water samples from the Ethiopian Rift Valley, and the results were found to be within the drinking water standards, thus indicating the capability of the developed products to purify contaminated water for human consumption.</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2023-05-10</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.22146/ijc.79024</dc:identifier><dc:identifier>10.22146/ijc.79024</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 23 No 3 (2023); 636-636</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:relation>https://jurnal.ugm.ac.id/ijc/article/download/79024/36220</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>