Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Limit Detection of Short Tandem Repeats (STR) Analysis on Touch DNA Samples

Indonesian Journal of Chemistry · Vol. 24 No. 5 (2024) · hlm. 1386–1386

DOI
10.22146/ijc.94081
ISSN
1411-9420, 2460-1578
Terbit
2024-10-01
Penerbit
Gadjah Mada University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

Forensic short tandem repeats (STR) profiling on touch DNA samples has emerged as a primary method for human identification. The stability and uniqueness of STR combination from the targeted locus in each individual make it a precision marker for human identification. Touch DNA samples can be found in traces of biological material shed from a person. This work aimed to identify the lowest concentration limit required for generating an interpretable DNA profile and the sensitivity of the STR loci applied. Touch DNA samples were collected from donors who were asked to hold a rope for 5 min. A double swab technique was used to lift the touch samples from the rope. These samples are subjected to DNA extraction and quantification. Two STR amplification cycles, 29 and 34 cycles, were used. DNA concentration greatly influences the success of amplifying the target allele at each STR locus to be interpreted into a complete DNA profile, shown by its allele peak. Touch DNA concentration >0.25 ng can produce a complete DNA profile. LCN method successfully amplified touch DNA with a concentration 0.0625–0.25 ng/µL. Limit detection of touch DNA analysis is 0.25 ng/µL. Low-copy DNA can still be analyzed within 0.0625–0.25 ng/µL.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 226 tautan kepenulisan bersama · 55 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • State University of Jakarta
  • National Research and Innovation Agency
  • Universitas Airlangga
  • Arnold Palmer Hospital for Children
  • University of Technology Malaysia
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Fera KurniadewiState University of Jakarta12
Irma Ratna KartikaState University of Jakarta10
Gladys Indira PutriState University of Jakarta9
Jefferson Lynford DeclanState University of Jakarta9
Hesham Ali El EnshasyUniversity of Technology Malaysia8
Bassam AbomoelakArnold Palmer Hospital for Children7
Dandy Akbar JuliansyahState University of Jakarta6
Adinda Myra Amalia PutriState University of Jakarta6
Atikah Nur RahmawatiState University of Jakarta6
I Made WiranathaAfiliasi tidak diketahui6
Nola MargaretUniversitas Airlangga5
NovitasariAfiliasi tidak diketahui4
Tiara FahrizaState University of Jakarta4
Ayu BerkahingrumState University of Jakarta4
Dalia SukmawatiState University of Jakarta4
Maharanianska AzzahraState University of Jakarta4
Irvan MaulanaState University of Jakarta4
Gusti Angieta PutriState University of Jakarta4
Soekry Erfan KusumaAfiliasi tidak diketahui3
Anisa FitriyantiState University of Jakarta3
Rara SeruniState University of Jakarta2
Fery SetiawanUniversitas Airlangga2
Yeti Eka Sispita SariUniversitas Airlangga2
Agung SosiawanUniversitas Airlangga2
Mieke Sylvia MARUniversitas Airlangga2
Khusnul KhotimahNational Research and Innovation Agency1
Vera PermatasariNational Research and Innovation Agency1
Irawan SukmaNational Research and Innovation Agency1
Wuwus ArdiatnaNational Research and Innovation Agency1
Siddiq Wahyu HidayatNational Research and Innovation Agency1
Asep Rahmat HidayatNational Research and Innovation Agency1
Ihsan SuponoNational Research and Innovation Agency1
Futi Kusuma HatiState University of Jakarta1
Nur Fadillah Adelia AzahraState University of Jakarta1
Fadhila Shofi AlbanaState University of Jakarta1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Limit Detection of Short Tandem Repeats (STR) Analysis on Touch DNA Samples</dc:title><dc:creator>Vira Saamia</dc:creator><dc:creator>Ahmad Yudianto</dc:creator><dc:creator>Muktiningsih Nurjayadi</dc:creator><dc:creator>Novitasari Novitasari</dc:creator><dc:creator>Abdul Hadi Furqoni</dc:creator><dc:subject>touch DNA</dc:subject><dc:subject>microsatellite markers</dc:subject><dc:subject>STR profiling</dc:subject><dc:subject>detection limit</dc:subject><dc:subject>DNA concentration</dc:subject><dc:subject>forensic human identification</dc:subject><dc:subject>DNA extraction</dc:subject><dc:description xml:lang="en">Forensic short tandem repeats (STR) profiling on touch DNA samples has emerged as a primary method for human identification. The stability and uniqueness of STR combination from the targeted locus in each individual make it a precision marker for human identification. Touch DNA samples can be found in traces of biological material shed from a person. This work aimed to identify the lowest concentration limit required for generating an interpretable DNA profile and the sensitivity of the STR loci applied. Touch DNA samples were collected from donors who were asked to hold a rope for 5 min. A double swab technique was used to lift the touch samples from the rope. These samples are subjected to DNA extraction and quantification. Two STR amplification cycles, 29 and 34 cycles, were used. DNA concentration greatly influences the success of amplifying the target allele at each STR locus to be interpreted into a complete DNA profile, shown by its allele peak. Touch DNA concentration &gt;0.25 ng can produce a complete DNA profile. LCN method successfully amplified touch DNA with a concentration 0.0625–0.25 ng/µL. Limit detection of touch DNA analysis is 0.25 ng/µL. Low-copy DNA can still be analyzed within 0.0625–0.25 ng/µL.</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2024-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.22146/ijc.94081</dc:identifier><dc:identifier>10.22146/ijc.94081</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 24 No 5 (2024); 1386-1386</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:relation>https://jurnal.ugm.ac.id/ijc/article/download/94081/39694</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>