Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Using Box-Behnken Design for Determination of Antimony(III) in Polyethylene Terephthalate by Inductively Coupled Plasma-Optical Emission Spectroscopy

Indonesian Journal of Chemistry · Vol. 25 No. 5 (2025) · hlm. 1514–1514

DOI
10.22146/ijc.105759
ISSN
1411-9420, 2460-1578
Terbit
2025-10-01
Penerbit
Gadjah Mada University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

Antimony (Sb), a toxic heavy metal, is widely used in plastic industries as a catalyst in producing polyethylene terephthalate (PET) due to its high catalytic efficiency and cost-effectiveness. However, its potential to leach into consumables raises significant health and environmental concerns, highlighting the need for accurate quantification methods. This study aimed to optimize microwave-assisted digestion (MW-AD) parameters for the determination of trace levels of Sb(III) in PET using inductively coupled plasma-optical emission spectroscopy (ICP-OES). A Box-Behnken Design (BBD) was employed to systematically optimize three critical factors: digestion temperature, digestion time, and sample weight. The statistical analysis confirmed the model’s reliability, with an R2 value of 0.9945, indicating a well-fitted model. The optimal conditions were determined as 200 °C digestion temperature, 15 min digestion time, and 0.1 g sample weight. Under optimal conditions, the method exhibited excellent analytical performance, achieving a limit of detection (LOD) of 1.079 mg L−1, a limit of quantification (LOQ) of 3.270 mg L−1, accuracy of 106% spike recovery, and precision with 0.81% relative standard deviation (RSD, n = 3). This validated method provides a rapid, sensitive, and efficient approach for the quantification of Sb(III) in PET samples.

Kata kunci

Jaringan kolaborasi para penulis

15 penulis · 50 tautan kepenulisan bersama · 12 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universiti Teknologi MARA
  • Universiti Sains Malaysia
  • Universiti Putra Malaysia
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Wan Nazihah Wan IbrahimUniversiti Teknologi MARA8
Norashikin SaimUniversiti Teknologi MARA5
Noorfatimah YahayaUniversiti Sains Malaysia4
Nursyamsyila Mat HadzirUniversiti Teknologi MARA4
Ungku Amirul Arif Ungku AbdullahUniversiti Teknologi MARA3
Mohammad Salim TabishUniversiti Teknologi MARA1
Nur Husna Zainal AbidinUniversiti Teknologi MARA1
Siti Efliza AshariUniversiti Putra Malaysia1
Rossuriati Dol HamidUniversiti Teknologi MARA1
Nurul Atikah Binti Amin YusofUniversiti Teknologi MARA1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Using Box-Behnken Design for Determination of Antimony(III) in Polyethylene Terephthalate by Inductively Coupled Plasma-Optical Emission Spectroscopy</dc:title><dc:creator>Nur Faten Hazira Mohd Ghazali</dc:creator><dc:creator>Nor Suhaila Mohamad Hanapi</dc:creator><dc:creator>Nurzaimah Zaini</dc:creator><dc:creator>Ahmad Lutfi Anis</dc:creator><dc:creator>Wan M. Asyraf Wan Mahmood</dc:creator><dc:subject>antimony(III)</dc:subject><dc:subject>polyethylene terephthalate</dc:subject><dc:subject>heavy metal leaching</dc:subject><dc:subject>microwave digestion</dc:subject><dc:subject>Box-Behnken design</dc:subject><dc:subject>ICP-OES determination</dc:subject><dc:subject>trace metal analysis</dc:subject><dc:description xml:lang="en">Antimony (Sb), a toxic heavy metal, is widely used in plastic industries as a catalyst in producing polyethylene terephthalate (PET) due to its high catalytic efficiency and cost-effectiveness. However, its potential to leach into consumables raises significant health and environmental concerns, highlighting the need for accurate quantification methods. This study aimed to optimize microwave-assisted digestion (MW-AD) parameters for the determination of trace levels of Sb(III) in PET using inductively coupled plasma-optical emission spectroscopy (ICP-OES). A Box-Behnken Design (BBD) was employed to systematically optimize three critical factors: digestion temperature, digestion time, and sample weight. The statistical analysis confirmed the model’s reliability, with an R2 value of 0.9945, indicating a well-fitted model. The optimal conditions were determined as 200 °C digestion temperature, 15 min digestion time, and 0.1 g sample weight. Under optimal conditions, the method exhibited excellent analytical performance, achieving a limit of detection (LOD) of 1.079 mg L−1, a limit of quantification (LOQ) of 3.270 mg L−1, accuracy of 106% spike recovery, and precision with 0.81% relative standard deviation (RSD, n = 3). This validated method provides a rapid, sensitive, and efficient approach for the quantification of Sb(III) in PET samples.</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2025-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.22146/ijc.105759</dc:identifier><dc:identifier>10.22146/ijc.105759</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 25 No 5 (2025); 1514-1514</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:relation>https://jurnal.ugm.ac.id/ijc/article/download/105759/42069</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>