Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

DEVELOPMENT OF FLOW INJECTION METHOD FOR ONLINE DETERMINATION OF THIOCYANATE BASED ON OXIDATION BY PERMANGANATE

Indonesian Journal of Chemistry · Vol. 10 No. 2 (2010) · hlm. 167–171

DOI
10.22146/ijc.21455
ISSN
1411-9420, 2460-1578
Terbit
2010-07-21
Penerbit
Gadjah Mada University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

The importance of developing method for thiocyanate becomes obvious, because thiocyanate can inhibit iodine uptake of thyroid gland leading to mumps disease. In this work, thiocyanate is oxidized by permanganate in the acid donor stream to cyanide, which is directly converted to hydrogen cyanide. Then, hydrogen cyanide diffuses through a Teflon membrane into acceptor stream containing nickel(II) in ammoniacal buffer to form tetracyanonickelate(II) which is detected spectrophotometrically at 267 nm. Analytical figures of merit were linear up to 50 mg L-1 for thiocyanate, with RSD of 1.34%, and detection limit of 0.07 mg L-1, respectively. Interfering anions were eliminated under stoichiometric amount of permanganate and sample throughput was 20 h-1. The method was validated for determining thiocyanate samples from synthetic and gold process waters with satisfactory results. Keywords: Thiocyanate, flow injection, permanganate, spectrophotometry

Kata kunci

Jaringan kolaborasi para penulis

21 penulis · 54 tautan kepenulisan bersama · 13 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Brawijaya
  • The University of Melbourne
  • Jenderal Soedirman University
  • Sultan Agung Islamic University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Akhmad SabarudinUniversity of Brawijaya2
Osfar SjofjanUniversity of Brawijaya2
Suyadi SuyadiUniversity of Brawijaya2
Puguh SurjowardojoUniversity of Brawijaya2
Afduha Nurus SyamsiJenderal Soedirman University2
Lilik Eka RadiatiUniversity of Brawijaya2
Tri Eko SusiloriniUniversity of Brawijaya2
Krista Firdaus Suwarno PutriUniversity of Brawijaya1
Setyawan P. SaktiUniversity of Brawijaya1
R SugiartoSultan Agung Islamic University1
Erwin SulistyoUniversity of Brawijaya1
Atikah AtikahUniversity of Brawijaya1
Adam WiryawanUniversity of Brawijaya1
Ani MulyasuryaniUniversity of Brawijaya1
Asnaili Alfi NurillahUniversity of Brawijaya1
Ahmad Luthfi FahmiUniversity of Brawijaya1
Kamila Rohadatul ‘AisyUniversity of Brawijaya1
Ika Oktavia WulandariUniversity of Brawijaya1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">DEVELOPMENT OF FLOW INJECTION METHOD FOR ONLINE DETERMINATION OF THIOCYANATE BASED ON OXIDATION BY PERMANGANATE</dc:title><dc:creator>Hermin Sulistyarti</dc:creator><dc:creator>Spas D. Kolev</dc:creator><dc:creator>Stephanie Lim</dc:creator><dc:subject>thiocyanate determination</dc:subject><dc:subject>flow injection analysis</dc:subject><dc:subject>potassium permanganate oxidation</dc:subject><dc:subject>hydrogen cyanide</dc:subject><dc:subject>tetracyanonickelate(II)</dc:subject><dc:subject>nickel(II) complexes</dc:subject><dc:subject>cyanide</dc:subject><dc:description xml:lang="en">The importance of developing method for thiocyanate becomes obvious, because thiocyanate can inhibit iodine uptake of thyroid gland leading to mumps disease. In this work, thiocyanate is oxidized by permanganate in the acid donor stream to cyanide, which is directly converted to hydrogen cyanide. Then, hydrogen cyanide diffuses through a Teflon membrane into acceptor stream containing nickel(II) in ammoniacal buffer to form tetracyanonickelate(II) which is detected spectrophotometrically at 267 nm. Analytical figures of merit were linear up to 50 mg L-1 for thiocyanate, with RSD of 1.34%, and detection limit of 0.07 mg L-1, respectively. Interfering anions were eliminated under stoichiometric amount of permanganate and sample throughput was 20 h-1. The method was validated for determining thiocyanate samples from synthetic and gold process waters with satisfactory results. Keywords: Thiocyanate, flow injection, permanganate, spectrophotometry</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2010-07-21</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://doi.org/10.22146/ijc.21455</dc:identifier><dc:identifier>10.22146/ijc.21455</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 10 No 2 (2010); 167-171</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>