Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Pre-Concentration and Determination of Tetracyclines Antibiotics Residues in Water Samples Using RGO/Fe3O4 Nanocomposite as Extraction Sorbent

Indonesian Journal of Chemistry · Vol. 21 No. 5 (2021) · hlm. 1196–1196

DOI
10.22146/ijc.64414
ISSN
1411-9420, 2460-1578
Terbit
2021-09-08
Penerbit
Gadjah Mada University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

Existing methods used in tracing Tetracyclines' antibiotics (TCAs) residues which pose serious environmental problems, consume high amounts of organic solvents, are time-consuming, and are relatively expensive. A simple and effective magnetic solid-phase extraction (MSPE) based on reduced graphene oxide/magnetite (RGO/Fe3O4) nanocomposite sorbent was successfully developed for preconcentration and extraction of TCAs residues from water samples. The analytes were determined by high-performance liquid chromatography with a diode-array detector (HPLC-DAD). The synthesized nanocomposite was characterized using Fourier-transform infrared spectroscopy (FTIR), X-ray diffractometry (XRD), and field emission scanning electron microscopy (FESEM). Sample pH, amount of adsorbent, sample volume, extraction time, desorption time, and desorption solvent were evaluated and optimized. Under optimized conditions, the method demonstrated good linearity over the concentration range of 0.05–1.0 mg L–1 with the coefficient of determination (R2) ≥ 0.9978. Limit of detection (LOD) and limit of quantification (LOQ) were 0.006–0.011 mg L–1 and 0.019–0.036 mg L–1, respectively. The accuracy and precision of the developed method were proven by good analyte recovery (89.77–106.33%) and acceptable precision with relative standard deviation, RSD ≤ 5.54%. The results showed that magnetic solid RGO/Fe3O4 could be a suitable adsorbent in the preconcentration and extraction of TCAs in water samples.

Kata kunci

Jaringan kolaborasi para penulis

21 penulis · 62 tautan kepenulisan bersama · 15 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universiti Teknologi MARA
  • University of Technology Malaysia
  • Universiti Sains Malaysia
  • Universiti Putra Malaysia
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Norashikin SaimUniversiti Teknologi MARA9
Mohammad Salim TabishUniversiti Teknologi MARA3
Nur Faten Hazira Mohd GhazaliUniversiti Teknologi MARA3
Wan M. Asyraf Wan MahmoodUniversiti Teknologi MARA3
Nur Husna Zainal AbidinUniversiti Teknologi MARA2
Siti Efliza AshariUniversiti Putra Malaysia2
Rossuriati Dol HamidUniversiti Teknologi MARA2
Nurul Atikah Binti Amin YusofUniversiti Teknologi MARA2
Sheela ChandrenUniversity of Technology Malaysia1
Imad Eddine AouissiUniversity of Technology Malaysia1
Norazah BasarUniversity of Technology Malaysia1
Sheikh Ahmad Izaddin Sheikh Mohd GhazaliUniversiti Teknologi MARA1
Ruhaida RusminUniversiti Teknologi MARA1
Nurul Ain Safiqah Md SandollahUniversiti Teknologi MARA1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Pre-Concentration and Determination of Tetracyclines Antibiotics Residues in Water Samples Using RGO/Fe3O4 Nanocomposite as Extraction Sorbent</dc:title><dc:creator>Ungku Amirul Arif Ungku Abdullah</dc:creator><dc:creator>Nor Suhaila Mohamad Hanapi</dc:creator><dc:creator>Wan Nazihah Wan Ibrahim</dc:creator><dc:creator>Nursyamsyila Mat Hadzir</dc:creator><dc:creator>Nurzaimah Zaini</dc:creator><dc:creator>Ahmad Lutfi Anis</dc:creator><dc:creator>Noorfatimah Yahaya</dc:creator><dc:subject>tetracycline</dc:subject><dc:subject>antibiotic residues</dc:subject><dc:subject>magnetic solid-phase extraction</dc:subject><dc:subject>reduced graphene oxide</dc:subject><dc:subject>magnetite</dc:subject><dc:subject>magnetic adsorbent</dc:subject><dc:subject>preconcentration</dc:subject><dc:subject>water samples</dc:subject><dc:subject>environmental pollutants</dc:subject><dc:description xml:lang="en">Existing methods used in tracing Tetracyclines' antibiotics (TCAs) residues which pose serious environmental problems, consume high amounts of organic solvents, are time-consuming, and are relatively expensive. A simple and effective magnetic solid-phase extraction (MSPE) based on reduced graphene oxide/magnetite (RGO/Fe3O4) nanocomposite sorbent was successfully developed for preconcentration and extraction of TCAs residues from water samples. The analytes were determined by high-performance liquid chromatography with a diode-array detector (HPLC-DAD). The synthesized nanocomposite was characterized using Fourier-transform infrared spectroscopy (FTIR), X-ray diffractometry (XRD), and field emission scanning electron microscopy (FESEM). Sample pH, amount of adsorbent, sample volume, extraction time, desorption time, and desorption solvent were evaluated and optimized. Under optimized conditions, the method demonstrated good linearity over the concentration range of 0.05–1.0 mg L–1 with the coefficient of determination (R2) ≥ 0.9978. Limit of detection (LOD) and limit of quantification (LOQ) were 0.006–0.011 mg L–1 and 0.019–0.036 mg L–1, respectively. The accuracy and precision of the developed method were proven by good analyte recovery (89.77–106.33%) and acceptable precision with relative standard deviation, RSD ≤ 5.54%. The results showed that magnetic solid RGO/Fe3O4 could be a suitable adsorbent in the preconcentration and extraction of TCAs in water samples.</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2021-09-08</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.22146/ijc.64414</dc:identifier><dc:identifier>10.22146/ijc.64414</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 21 No 5 (2021); 1196-1196</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:relation>https://jurnal.ugm.ac.id/ijc/article/download/64414/31901</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>