Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Proteins Pre-concentration Using Glycidyl Methacrylate-co-stearyl Methacrylate-co-ethylene Glycol Dimethacrylate Monolith

Indonesian Journal of Chemistry · Vol. 20 No. 5 (2020) · hlm. 1143–1143

DOI
10.22146/ijc.49479
ISSN
1411-9420, 2460-1578
Terbit
2020-07-18
Penerbit
Gadjah Mada University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

Solid-phase extraction technique is considered as a vital tool in a pre-treatment of different samples. Therefore, it was used as a beneficial and alternative extraction method over the liquid–liquid extraction in diverse applications such as food, environmental, and biological analyses. Glycidyl methacrylate-co-stearyl methacrylate-co-ethylene glycol dimethacrylate (GMA-co-SMA-co-EDMA) monolithic sorbent was prepared as strong cationic-reversed phase sorbent for solid-phase extraction of different proteins. The monolithic sorbent was prepared inside two moulds such as glass microchip device and borosilicate. The morphological properties have been investigated using the Brunauer-Emmett-Teller (BET) model analyzer and scanning electron microscope (SEM), and the formation of the monolithic sorbent was examined using the FT-IR. Eight proteins (cytochrome C, insulin, myoglobin, lysozyme, β-lactoglobulin, trypsin, albumin chicken egg white, and apo-transferrin) with different molecular weight and isoelectric point were investigated for pre-concentration using the SCX/RP sorbent. It was found that the highest extraction recovery was obtained with three proteins cytochrome C, lysozyme, and myoglobin compared with the other proteins. These three proteins were chosen for pre-concentration using the glass microchip. Sorbent performance showed significant results in terms of stability and reproducibility.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 7 tautan kepenulisan bersama · 4 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Babylon
  • University of Hull
  • The Open University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Rana A. K. Al-Refai’aUniversity of Babylon1
Eman Hameed Al-RikabiUniversity of Babylon1
Rafaela VasiliadouThe Open University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Proteins Pre-concentration Using Glycidyl Methacrylate-co-stearyl Methacrylate-co-ethylene Glycol Dimethacrylate Monolith</dc:title><dc:creator>Ahmed Ali Alkarimi</dc:creator><dc:creator>Kevin J. Welham</dc:creator><dc:subject>solid-phase extraction</dc:subject><dc:subject>monolithic sorbents</dc:subject><dc:subject>glycidyl methacrylate</dc:subject><dc:subject>stearyl methacrylate</dc:subject><dc:subject>ethylene glycol dimethacrylate</dc:subject><dc:subject>glass microchips</dc:subject><dc:subject>cytochrome c</dc:subject><dc:subject>lysozyme</dc:subject><dc:subject>myoglobin</dc:subject><dc:description xml:lang="en">Solid-phase extraction technique is considered as a vital tool in a pre-treatment of different samples. Therefore, it was used as a beneficial and alternative extraction method over the liquid–liquid extraction in diverse applications such as food, environmental, and biological analyses. Glycidyl methacrylate-co-stearyl methacrylate-co-ethylene glycol dimethacrylate (GMA-co-SMA-co-EDMA) monolithic sorbent was prepared as strong cationic-reversed phase sorbent for solid-phase extraction of different proteins. The monolithic sorbent was prepared inside two moulds such as glass microchip device and borosilicate. The morphological properties have been investigated using the Brunauer-Emmett-Teller (BET) model analyzer and scanning electron microscope (SEM), and the formation of the monolithic sorbent was examined using the FT-IR. Eight proteins (cytochrome C, insulin, myoglobin, lysozyme, β-lactoglobulin, trypsin, albumin chicken egg white, and apo-transferrin) with different molecular weight and isoelectric point were investigated for pre-concentration using the SCX/RP sorbent. It was found that the highest extraction recovery was obtained with three proteins cytochrome C, lysozyme, and myoglobin compared with the other proteins. These three proteins were chosen for pre-concentration using the glass microchip. Sorbent performance showed significant results in terms of stability and reproducibility.</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2020-07-18</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.22146/ijc.49479</dc:identifier><dc:identifier>10.22146/ijc.49479</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 20 No 5 (2020); 1143-1143</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:relation>https://jurnal.ugm.ac.id/ijc/article/download/49479/26739</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>