Akses terbuka
Jurnal
SINTA 1
DIFFERENTIAL PULSE ANODIC STRIPPING VOLTAMMETRY FOR DETERMINATION OF SOME HEAVY METALS IN URANIUM
Indonesian Journal of Chemistry · Vol. 9 No. 2 (2010) · hlm. 243–246
ISSN 1411-9420, 2460-1578
Terbit 2010-06-22
Penerbit Gadjah Mada University
Bahasa en
Abstrak
The direct determination of some metals impurity in uranium by using differential pulse anodic stripping voltammetry (DPASV) method at a hanging mercury drop electrode and in a carbonate buffer media was developed. It was found that the carbonate buffer show the strongest affinity for uranium and gives the best separation between the DPASV peaks of heavy metals impurities. The carbonate concentration markedly affects the oxidation and reduction the major and the minor constituents of the uranium samples. In 0.1 M carbonate buffer solution pH 10, copper, bismuth, thalium, lead, cadmium, zinc, could be determined without the removal of the uranium matrix. Recovery and relative standard deviation (RSD) of this method was in the range of 174% - 85.2% for recovery and 36.8% - 1.2% for RSD. The larger error of analytical result was obtained for Zn at low concentration. In general, the analytic results error and RSD decreased with increasing metals concentration. Keywords: heavy metal determination, differential pulse anodic stripping voltammetry, uranium
Jaringan kolaborasi para penulis
2 penulis ·
1 tautan kepenulisan bersama
· 1 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
National Nuclear Energy Agency of Indonesia IPB University
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">DIFFERENTIAL PULSE ANODIC STRIPPING VOLTAMMETRY FOR DETERMINATION OF SOME HEAVY METALS IN URANIUM</dc:title><dc:creator>Saryati Saryati</dc:creator><dc:subject>differential pulse anodic stripping voltammetry</dc:subject><dc:subject>heavy metal impurities</dc:subject><dc:subject>uranium</dc:subject><dc:subject>hanging mercury drop electrode</dc:subject><dc:subject>carbonate buffer</dc:subject><dc:subject>copper</dc:subject><dc:subject>bismuth</dc:subject><dc:subject>thallium</dc:subject><dc:subject>lead</dc:subject><dc:subject>cadmium</dc:subject><dc:subject>zinc</dc:subject><dc:subject>matrix effects</dc:subject><dc:description xml:lang="en">The direct determination of some metals impurity in uranium by using differential pulse anodic stripping voltammetry (DPASV) method at a hanging mercury drop electrode and in a carbonate buffer media was developed. It was found that the carbonate buffer show the strongest affinity for uranium and gives the best separation between the DPASV peaks of heavy metals impurities. The carbonate concentration markedly affects the oxidation and reduction the major and the minor constituents of the uranium samples. In 0.1 M carbonate buffer solution pH 10, copper, bismuth, thalium, lead, cadmium, zinc, could be determined without the removal of the uranium matrix. Recovery and relative standard deviation (RSD) of this method was in the range of 174% - 85.2% for recovery and 36.8% - 1.2% for RSD. The larger error of analytical result was obtained for Zn at low concentration. In general, the analytic results error and RSD decreased with increasing metals concentration. Keywords: heavy metal determination, differential pulse anodic stripping voltammetry, uranium</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2010-06-22</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://doi.org/10.22146/ijc.21537</dc:identifier><dc:identifier>10.22146/ijc.21537</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 9 No 2 (2010); 243-246</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Terindeks
lewat ID karya OpenAlex (record dari sumber OpenAlex)
2 sitasi
Crossref
Terindeks
lewat DOI
2 sitasi
Jumlah menurut tiap indeks pada 19 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref, doaj.
Sitasi artikel ini
APA 7
Saryati, S. (2010). DIFFERENTIAL PULSE ANODIC STRIPPING VOLTAMMETRY FOR DETERMINATION OF SOME HEAVY METALS IN URANIUM. Indonesian Journal of Chemistry, 9(2), 243–246. https://doi.org/10.22146/ijc.21537
Salin
IEEE
S. Saryati, “DIFFERENTIAL PULSE ANODIC STRIPPING VOLTAMMETRY FOR DETERMINATION OF SOME HEAVY METALS IN URANIUM,” Indonesian Journal of Chemistry, vol. 9, no. 2, pp. 243–246, 2010, doi: 10.22146/ijc.21537.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.