Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Spectrofluorimetric Method for Simultaneous Determination of Trimethoprim and Sulfamethoxazole with O-phthaladehyde Reagent by H-point Standard Addition Method

Indonesian Journal of Chemistry · Vol. 24 No. 5 (2024) · hlm. 1377–1377

DOI
10.22146/ijc.93864
ISSN
1411-9420, 2460-1578
Terbit
2024-10-01
Penerbit
Gadjah Mada University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

Simultaneous spectrofluorometric method described for the determination of trimethoprim (TMP) and sulfamethoxazole (SMZ) in pure and pharmaceutical preparations using H-point standard addition method (HPSAM) according to the reaction of nanograms of drugs with O-phthaladehyde (OPA) reagent to forms highly fluorescence compounds. The formed fluorophore excitation and emission at 342 and 458 nm, respectively, for OPA-TMP compound, at 424 and 508 nm, respectively, for OPA-SMZ compound under basic condition (pH 9.8) in the presence of 2-mercabtoethanol. A simple and accurate HPSAM is reported to resolve the overlapping in the fluorescence spectrum of these two drugs without prior separation of samples. The linear range was 100–1200 ng/mL for TMP and 100–1100 ng/mL for SMZ. The LOD and LOQ were 16.64 and 36.80 ng/mL, as well as 15.76 and 33.88 ng/mL for TMP and SMZ, respectively. The relative standard deviations and recovery percentages were 0.641% and 101.29% for TMP as well as 0.558% and 100.96% for SMZ, respectively. The procedure has been applied successfully in various pharmaceutical preparations. It was discovered that the experimental F- and t-values at a 95% confidence level were no higher than the theoretical values, showing that the HPSAM method is accurate and valid.

Kata kunci

Jaringan kolaborasi para penulis

4 penulis · 4 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Babylon
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Khudheyer Jawad KademUniversity of Babylon1
Fatimah Hameed FlayyihUniversity of Babylon1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Spectrofluorimetric Method for Simultaneous Determination of Trimethoprim and Sulfamethoxazole with O-phthaladehyde Reagent by H-point Standard Addition Method</dc:title><dc:creator>Amneen Mohammed Alsayegh</dc:creator><dc:creator>Abbas Noor Alshirifi</dc:creator><dc:subject>trimethoprim</dc:subject><dc:subject>sulfamethoxazole</dc:subject><dc:subject>simultaneous determination</dc:subject><dc:subject>H-point standard addition method</dc:subject><dc:subject>fluorescence spectrophotometry</dc:subject><dc:subject>sulfonamide antibiotics</dc:subject><dc:subject>pharmaceutical preparations</dc:subject><dc:subject>2-mercaptoethanol</dc:subject><dc:subject>fluorescence quenching</dc:subject><dc:description xml:lang="en">Simultaneous spectrofluorometric method described for the determination of trimethoprim (TMP) and sulfamethoxazole (SMZ) in pure and pharmaceutical preparations using H-point standard addition method (HPSAM) according to the reaction of nanograms of drugs with O-phthaladehyde (OPA) reagent to forms highly fluorescence compounds. The formed fluorophore excitation and emission at 342 and 458 nm, respectively, for OPA-TMP compound, at 424 and 508 nm, respectively, for OPA-SMZ compound under basic condition (pH 9.8) in the presence of 2-mercabtoethanol. A simple and accurate HPSAM is reported to resolve the overlapping in the fluorescence spectrum of these two drugs without prior separation of samples. The linear range was 100–1200 ng/mL for TMP and 100–1100 ng/mL for SMZ. The LOD and LOQ were 16.64 and 36.80 ng/mL, as well as 15.76 and 33.88 ng/mL for TMP and SMZ, respectively. The relative standard deviations and recovery percentages were 0.641% and 101.29% for TMP as well as 0.558% and 100.96% for SMZ, respectively. The procedure has been applied successfully in various pharmaceutical preparations. It was discovered that the experimental F- and t-values at a 95% confidence level were no higher than the theoretical values, showing that the HPSAM method is accurate and valid.</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2024-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.22146/ijc.93864</dc:identifier><dc:identifier>10.22146/ijc.93864</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 24 No 5 (2024); 1377-1377</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:relation>https://jurnal.ugm.ac.id/ijc/article/download/93864/39377</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>