Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Accessible Protein Quantification with a Low-Cost Spectrophotometer Using Bradford Reagent

Indonesian Journal of Chemistry · Vol. 25 No. 6 (2025) · hlm. 1680–1680

DOI
10.22146/ijc.99362
ISSN
1411-9420, 2460-1578
Terbit
2025-12-01
Penerbit
Gadjah Mada University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

Ensuring accessible and cost-effective laboratory equipment is essential for advancing scientific research in resource-limited settings. This study introduces a novel; low-cost spectrophotometer built with an Arduino microcontroller and a BH1750 light sensor to measure protein concentration using the Bradford method. The device features a 595 nm LED as the light source, encased in a 3D-printed PLA filament housing. Casein served as the standard protein for calibration and testing. The system demonstrated a linear detection range of 100 to 700 ppm, with a regression equation of y = 0.0007x + 0.1418 and a high correlation coefficient (R2 = 0.9921) compared to commercial spectrophotometers. The limit of detection and quantification were 58.43 and 194.77 ppm, respectively. Precision was confirmed with a HORRAT value of 0.161 using a 500 ppm sample, and accuracy was 103.34% for a 100 ppm sample. The device showed good selectivity against 200 ppm glucose interference. This open-source solution significantly reduces the cost of spectrophotometric analysis while improving accessibility in educational and remote laboratories. The practical implication of this study is it has strong potential for use in educational settings and field-based protein quantification due to its low cost, portability, and adequate performance.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 136 tautan kepenulisan bersama · 36 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Jenderal Soedirman University
  • Bandung Institute of Technology
  • IPB University
  • Tohoku University
  • Institute of Multidisciplinary Research for Advanced Materials, Tohoku University
  • National Research and Innovation Agency
  • Sebelas Maret University
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Uyi SulaemanJenderal Soedirman University7
Dian Riana NingsihJenderal Soedirman University6
Zusfahair ZusfahairJenderal Soedirman University6
Bilalodin BilalodinJenderal Soedirman University4
Ari AsnaniJenderal Soedirman University4
Shu YinTohoku University4
Suwandri SuwandriJenderal Soedirman University3
Yana Maolana SyahBandung Institute of Technology2
Lia Dewi JuliawatyBandung Institute of Technology2
Marlia SinggihBandung Institute of Technology2
Niken Istikhari MuslihahJenderal Soedirman University2
Roy AndreasJenderal Soedirman University2
Khusnul AfifahJenderal Soedirman University2
Khansa SalsabilaSebelas Maret University2
Mudasir MudasirUniversitas Gadjah Mada2
Ponco IswantoJenderal Soedirman University2
Cacu CacuJenderal Soedirman University2
Hassan Youssef Aboul-EneinAfiliasi tidak diketahui2
Puji LestariJenderal Soedirman University1
Isnaeni IsnaeniNational Research and Innovation Agency1
Vania Amelia AzmiJenderal Soedirman University1
Rini LarasatiInstitute of Multidisciplinary Research for Advanced Materials, Tohoku University1
KUSWANDI KUSWANDIAfiliasi tidak diketahui1
I Made ArtikaIPB University1
AHMAD ENDANG ZAINAL HASANIPB University1
Nina SetiawatiJenderal Soedirman University1
Meivita Dewi PurnamasariJenderal Soedirman University1
Luciana PeppyAfiliasi tidak diketahui1
Sri IndrianiJenderal Soedirman University1
Eva Vaulina Yulistia DelsyJenderal Soedirman University1
Restu PamukasariJenderal Soedirman University1
Warsinah WarsinahJenderal Soedirman University1
Eka Prasasti Nur RachmaniJenderal Soedirman University1
Aprilia Nafi NurainiJenderal Soedirman University1
Ely SetiawanJenderal Soedirman University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Accessible Protein Quantification with a Low-Cost Spectrophotometer Using Bradford Reagent</dc:title><dc:creator>Novia Rahmandani Shoobiroh</dc:creator><dc:creator>Dadan Hermawan</dc:creator><dc:creator>Hartiwi Diastuti</dc:creator><dc:creator>Mekar Dwi Anggraeni</dc:creator><dc:creator>Amin Fatoni</dc:creator><dc:subject>low-cost spectrophotometer</dc:subject><dc:subject>protein quantification</dc:subject><dc:subject>Bradford assay</dc:subject><dc:subject>Arduino</dc:subject><dc:subject>BH1750 light sensor</dc:subject><dc:subject>3D-printed housing</dc:subject><dc:subject>resource-limited settings</dc:subject><dc:subject>remote laboratory</dc:subject><dc:subject>glucose interference</dc:subject><dc:description xml:lang="en">Ensuring accessible and cost-effective laboratory equipment is essential for advancing scientific research in resource-limited settings. This study introduces a novel; low-cost spectrophotometer built with an Arduino microcontroller and a BH1750 light sensor to measure protein concentration using the Bradford method. The device features a 595 nm LED as the light source, encased in a 3D-printed PLA filament housing. Casein served as the standard protein for calibration and testing. The system demonstrated a linear detection range of 100 to 700 ppm, with a regression equation of y = 0.0007x + 0.1418 and a high correlation coefficient (R2 = 0.9921) compared to commercial spectrophotometers. The limit of detection and quantification were 58.43 and 194.77 ppm, respectively. Precision was confirmed with a HORRAT value of 0.161 using a 500 ppm sample, and accuracy was 103.34% for a 100 ppm sample. The device showed good selectivity against 200 ppm glucose interference. This open-source solution significantly reduces the cost of spectrophotometric analysis while improving accessibility in educational and remote laboratories. The practical implication of this study is it has strong potential for use in educational settings and field-based protein quantification due to its low cost, portability, and adequate performance.</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2025-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.22146/ijc.99362</dc:identifier><dc:identifier>10.22146/ijc.99362</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 25 No 6 (2025); 1680-1680</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:relation>https://jurnal.ugm.ac.id/ijc/article/download/99362/42688</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>