Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

A Novel Stability-Indicating Method for Simultaneous Estimation of Glycopyrronium Bromide and Neostigmine Methyl Sulfate Injectable Formulations by RP-HPLC

Indonesian Journal of Chemistry · Vol. 26 No. 1 (2026) · hlm. 315–315

DOI
10.22146/ijc.106427
ISSN
1411-9420, 2460-1578
Terbit
2026-01-24
Penerbit
Gadjah Mada University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

Glycopyrronium bromide and neostigmine methyl sulfate drugs combination is used in treatment as an injectable formulation. The present study proposes the development and validation of an accurate, selective, and sensitive RP-HPLC method, which will enable the detection of degradation products for the combined estimation of glycopyrronium bromide and neostigmine methyl sulfate in both the parental dosage form and bulk samples. The optimum chromatographic condition was achieved using an octadecylsilane column, such as the Inertsil ODS-3 column with dimensions of 150 × 4.6 µm, 3 µm, at a flow rate of 1.00 mL/min with gradient elution. Phosphate buffer (pH 2.50) and acetonitrile were used as solutions A and B, respectively. Chromatography was achieved with an injection volume of 10 µL and a detection wavelength of 220 nm. The proposed study found a linear relationship between the ranges of 25–75 and 125–375 ppm for glycopyrronium and neostigmine methyl sulfate, respectively. The limit of detection and limit of quantification were achieved at 0.15 and 0.5 ppm for glycopyrronium bromide and neostigmine methyl sulfate, respectively. The validation of the method was carried out with a short run time of 20 min and a recovery rate of more than 99%.

Kata kunci

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • RK University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">A Novel Stability-Indicating Method for Simultaneous Estimation of Glycopyrronium Bromide and Neostigmine Methyl Sulfate Injectable Formulations by RP-HPLC</dc:title><dc:creator>C Mashru</dc:creator><dc:creator>Jayesh M. Dhalani</dc:creator><dc:subject>glycopyrrolate</dc:subject><dc:subject>stability-indicating assay</dc:subject><dc:subject>simultaneous estimation</dc:subject><dc:subject>injectable formulation</dc:subject><dc:subject>degradation products</dc:subject><dc:subject>RP-HPLC method validation</dc:subject><dc:subject>anticholinergic agents</dc:subject><dc:description xml:lang="en">Glycopyrronium bromide and neostigmine methyl sulfate drugs combination is used in treatment as an injectable formulation. The present study proposes the development and validation of an accurate, selective, and sensitive RP-HPLC method, which will enable the detection of degradation products for the combined estimation of glycopyrronium bromide and neostigmine methyl sulfate in both the parental dosage form and bulk samples. The optimum chromatographic condition was achieved using an octadecylsilane column, such as the Inertsil ODS-3 column with dimensions of 150 × 4.6 µm, 3 µm, at a flow rate of 1.00 mL/min with gradient elution. Phosphate buffer (pH 2.50) and acetonitrile were used as solutions A and B, respectively. Chromatography was achieved with an injection volume of 10 µL and a detection wavelength of 220 nm. The proposed study found a linear relationship between the ranges of 25–75 and 125–375 ppm for glycopyrronium and neostigmine methyl sulfate, respectively. The limit of detection and limit of quantification were achieved at 0.15 and 0.5 ppm for glycopyrronium bromide and neostigmine methyl sulfate, respectively. The validation of the method was carried out with a short run time of 20 min and a recovery rate of more than 99%.</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2026-01-24</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://doi.org/10.22146/ijc.106427</dc:identifier><dc:identifier>10.22146/ijc.106427</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 26 No 1 (2026); 315-315</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>