Abstrak

In general, wastewater treatment by physical, chemical and biological methods are only focused on TSS, BOD and COD removals that the effluent still contains anion pollutant as NO2- and S2-. Electrochemical technology is a proper method for those pollutants treatment due to its fast process, easy operation and minimum amount of sludge. Electrocatalytic reactor with 8 L capacity using Ti/RuIrO2 cylinder as anode and Fe plate as cathode was arranged and applied to treat anion pollutants. Hydraulic retention time (30, 60, 90 and 120 min), salt concentration (250, 500 and 750 mg/L) and voltage (4, 5, and 6 V) were chosen as operation variables and NO2- and S2- concentrations as parameter indicators. Nitrite removal efficiency reached 75 and 99.7% after 60 and 120 min of electrolysis, respectively, while sulfide could obtain higher efficiency, i.e., 97 and 99.9% after 60 and 90 min, respectively, at operation variables of potential of 5 V and salt of 500 mg/L. Removal process is dominated by indirect oxidation mechanism by HClO/ClO- oxidators generated at anode surface as intermediate products. The lifespan of electrode and electric consumption are two main factors of operation cost. Electric consumed was 0.452 kWh per 1 g nitrite removed.

Kata kunci

Jaringan kolaborasi para penulis

38 penulis · 108 tautan kepenulisan bersama · 30 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Sebelas Maret University
  • Institut Teknologi Sepuluh Nopember
  • Diponegoro University
  • Universitas Gadjah Mada
  • National Research and Innovation Agency
  • Lappeenranta-Lahti University of Technology
  • Pertamina (Indonesia)
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Arif JumariSebelas Maret University3
Cornelius Satria YudhaSebelas Maret University2
Eva Oktavia NingrumInstitut Teknologi Sepuluh Nopember2
Kamtiyah NingsihDiponegoro University1
Fuad MuhammadDiponegoro University1
Anif JamaluddinSebelas Maret University1
Anafi Nur’ainiLappeenranta-Lahti University of Technology1
Shofirul Sholikhatun NisaSebelas Maret University1
Endah Retno DyartantiSebelas Maret University1
Tika ParamithaSebelas Maret University1
Adrian NurSebelas Maret University1
Anatta Wahyu BudimanSebelas Maret University1
Anggia Putri GustamiAfiliasi tidak diketahui1
Witri Wahyu LestariSebelas Maret University1
Fitria RahmawatiSebelas Maret University1
Viona NataliaSebelas Maret University1
Hendri WidiyandariSebelas Maret University1
Soraya Ulfa MuzayanhaPertamina (Indonesia)1
Luthfi Mufidatul HasanahSebelas Maret University1
Linggar Tungga GupitaSebelas Maret University1
Galuh Chynintya Rosita RositaInstitut Teknologi Sepuluh Nopember1
Asep BagusInstitut Teknologi Sepuluh Nopember1
Sumarno SumarnoInstitut Teknologi Sepuluh Nopember1
Eka Octaviyatna MulyadiInstitut Teknologi Sepuluh Nopember1
Dinny Islamiah DewitasariInstitut Teknologi Sepuluh Nopember1
Agus KuncakaUniversitas Gadjah Mada1
Karna WijayaUniversitas Gadjah Mada1
Januar Arif FatkhurrahmanBandung Institute of Technology1
Rustiana YuliasniAfiliasi tidak diketahui1
Nur ZenAfiliasi tidak diketahui1
Kukuh Aryo WicaksonoAfiliasi tidak diketahui1
Hanny VistantyAfiliasi tidak diketahui1
Rizal Awaludin MalikAfiliasi tidak diketahui1
Wara Dyah Pita RenggaState University of Semarang1
Anne ZulfiaUniversity of Indonesia1
Enni ApriliyaniSebelas Maret University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Removal Efficiency of Nitrite and Sulfide Pollutants by Electrochemical Process by Using Ti/RuIrO2 Anode</dc:title><dc:creator>Aris Mukimin</dc:creator><dc:creator>Agus Purwanto</dc:creator><dc:subject>nitrite removal</dc:subject><dc:subject>sulfide removal</dc:subject><dc:subject>electrochemical wastewater treatment</dc:subject><dc:subject>indirect oxidation</dc:subject><dc:subject>hypochlorous acid</dc:subject><dc:subject>hypochlorite</dc:subject><dc:subject>hydraulic retention time</dc:subject><dc:subject>salt concentration</dc:subject><dc:subject>voltage effect</dc:subject><dc:subject>energy consumption</dc:subject><dc:description xml:lang="en">In general, wastewater treatment by physical, chemical and biological methods are only focused on TSS, BOD and COD removals that the effluent still contains anion pollutant as NO2- and S2-. Electrochemical technology is a proper method for those pollutants treatment due to its fast process, easy operation and minimum amount of sludge. Electrocatalytic reactor with 8 L capacity using Ti/RuIrO2 cylinder as anode and Fe plate as cathode was arranged and applied to treat anion pollutants. Hydraulic retention time (30, 60, 90 and 120 min), salt concentration (250, 500 and 750 mg/L) and voltage (4, 5, and 6 V) were chosen as operation variables and NO2- and S2- concentrations as parameter indicators. Nitrite removal efficiency reached 75 and 99.7% after 60 and 120 min of electrolysis, respectively, while sulfide could obtain higher efficiency, i.e., 97 and 99.9% after 60 and 90 min, respectively, at operation variables of potential of 5 V and salt of 500 mg/L. Removal process is dominated by indirect oxidation mechanism by HClO/ClO- oxidators generated at anode surface as intermediate products. The lifespan of electrode and electric consumption are two main factors of operation cost. Electric consumed was 0.452 kWh per 1 g nitrite removed.</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2018-05-30</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.22146/ijc.26609</dc:identifier><dc:identifier>10.22146/ijc.26609</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 18 No 2 (2018); 286-286</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:relation>https://jurnal.ugm.ac.id/ijc/article/download/26609/19533</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>