Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

PRE-CONCENTRATION AND DETERMINATION OF HEAVY METALS ON MODIFIED ACTIVATED CARBON IN REAL SAMPLES

Indonesian Journal of Chemistry · Vol. 8 No. 2 (2010) · hlm. 130–135

DOI
10.22146/ijc.21613
ISSN
1411-9420, 2460-1578
Terbit
2010-06-17
Penerbit
Gadjah Mada University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

A sensitive and simple method for the simultaneous pre-concentration of nutritionally important minerals in real samples has been reported. The method is based on the formation of metal complexes by N, N'-diacetyl-4-bromo-2, 6-di (aminomethyl) phenol (DBDP) loaded on activated carbon. The metals content on the complexes are then eluted using 6mL 4M HNO3, which are detected by AAS at resonance line. In this procedure, minerals such as Ni, Cu, Co, Pb Zn and Cd can be analyzed in one run by caring out the simultaneous separation and quantification of them. At optimum condition the response are linear over concentration range of for 0.03-1.1 µg mL-1 for Ni2+, 0.03-1.0 µg mL-1 for Cu2+, 0.02-1.0 µg mL-1 for Pb2+, 0.02-1.0 µg mL-1 for Co2+,0.02-1.1 µg mL-1 Zn2+ and 0.05-1.3 µg mL-1for Cd2+. The detection limits of each element are expressed as the amount of analytes in µg mL-1 giving a signal to noise ratio of 3 are equal to 2.5, 2.4, 1.6, 2.4, 1.9 and 2.1 for Ni2+, Cu2+, Pb2+, Co2+,Zn2+ and Cd2+. The ability of method for repeatable recovery of trace ion are 99.9, 98.7, 99.2, 98.7, 98.5and 95.6 with R.S.D of 1.3, 1.4, 1.2, 1.4, 1.7 and 1.4 for Ni2+, Cu2+, Pb2+, Co2+,Zn2+ and Cd2+. The method has been successfully applied for these metals content evaluation in some real samples including natural water and vegetable. Keywords: Heavy Metals, N, N'-diacetyl-4-bromo-2,6-di(aminomethyl) phenol (DBDP), Activated Carbon

Kata kunci

Jaringan kolaborasi para penulis

6 penulis · 9 tautan kepenulisan bersama · 3 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Islamic Azad University of Gachsaran
  • Islamic Azad University, Tehran
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
F. AhmadiaIslamic Azad University of Gachsaran1
Akbar MalekpourIslamic Azad University of Gachsaran1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">PRE-CONCENTRATION AND DETERMINATION OF HEAVY METALS ON MODIFIED ACTIVATED CARBON IN REAL SAMPLES</dc:title><dc:creator>F. Ahmadi</dc:creator><dc:creator>Khodabakhsh Niknam</dc:creator><dc:creator>A. Khanmohammadi</dc:creator><dc:creator>Zahra Adibmehr</dc:creator><dc:subject>heavy metals</dc:subject><dc:subject>preconcentration</dc:subject><dc:subject>activated carbon</dc:subject><dc:subject>metal chelates</dc:subject><dc:subject>nickel</dc:subject><dc:subject>copper</dc:subject><dc:subject>cobalt</dc:subject><dc:subject>lead</dc:subject><dc:subject>zinc</dc:subject><dc:subject>cadmium</dc:subject><dc:subject>simultaneous determination</dc:subject><dc:subject>natural waters</dc:subject><dc:subject>vegetables</dc:subject><dc:description xml:lang="en">A sensitive and simple method for the simultaneous pre-concentration of nutritionally important minerals in real samples has been reported. The method is based on the formation of metal complexes by N, N'-diacetyl-4-bromo-2, 6-di (aminomethyl) phenol (DBDP) loaded on activated carbon. The metals content on the complexes are then eluted using 6mL 4M HNO3, which are detected by AAS at resonance line. In this procedure, minerals such as Ni, Cu, Co, Pb Zn and Cd can be analyzed in one run by caring out the simultaneous separation and quantification of them. At optimum condition the response are linear over concentration range of for 0.03-1.1 µg mL-1 for Ni2+ , 0.03-1.0 µg mL-1 for Cu2+, 0.02-1.0 µg mL-1 for Pb2+ , 0.02-1.0 µg mL-1 for Co2+,0.02-1.1 µg mL-1 Zn2+ and 0.05-1.3 µg mL-1for Cd2+. The detection limits of each element are expressed as the amount of analytes in µg mL-1 giving a signal to noise ratio of 3 are equal to 2.5, 2.4, 1.6, 2.4, 1.9 and 2.1 for Ni2+ , Cu2+, Pb2+ , Co2+,Zn2+ and Cd2+. The ability of method for repeatable recovery of trace ion are 99.9, 98.7, 99.2 , 98.7, 98.5and 95.6 with R.S.D of 1.3, 1.4, 1.2, 1.4, 1.7 and 1.4 for Ni2+ , Cu2+, Pb2+ , Co2+,Zn2+ and Cd2+. The method has been successfully applied for these metals content evaluation in some real samples including natural water and vegetable. Keywords: Heavy Metals, N, N'-diacetyl-4-bromo-2,6-di(aminomethyl) phenol (DBDP), Activated Carbon</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2010-06-17</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>http://doi.org/10.22146/ijc.21613</dc:identifier><dc:identifier>10.22146/ijc.21613</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 8 No 2 (2010); 130-135</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>