Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

THE EFFECT OF PVC-BASED MEMBRANE COMPOSITION AND Zn(II), Cd(II) AND Pb(II) INTERFERING IONS TO Hg(II) ION SELECTIVE ELECTRODE (ISE) PERFORMANCE BY USING DBA218C6 IONOPHORE

Indonesian Journal of Chemistry · Vol. 6 No. 1 (2010) · hlm. 27–31

DOI
10.22146/ijc.21768
ISSN
1411-9420, 2460-1578
Terbit
2010-06-13
Penerbit
Gadjah Mada University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

The effect of PVC (Polyvinylchloride)-Based Membrane Composition to Ion Selective Electrode (ISE)-Hg(II) Performance using Ionophore DBA218C6 (N,N'-Dibenzyl-1,4,10,13-tetraoxa-7,16-diazacyclo octadecane), Plasticizer NPOE (Nitrophenyl Octhyl Ether), Anionic Site KTCPB (Potassium Tetrakis (4-chloro phenyl) borate) have been performed. Membrane compositions used were:(a) PVC (30 mg), NPOE (60 mg), DBA218C6(6 mg) and KTCPB (4 mg); (b) PVC(30 mg), NPOE (60 mg), DBA218C6(7 mg) and KTCPB (3 mg); (c) PVC (30 mg), NPOE (59 mg), DBA218C6 (8 mg) and KTCPB( 3 mg). The concentration range of interference ions Zn(II), Cd(II) and Pb(II) were 1.0 x 10-3 - 1.0 x 10-1 M. ISE-Hg(II) performance for membrane composition of 30: 60: 6: 4 was 26.34 mV per decade (Nernstian Slope value) on Hg(II) concentration range of 1.0x10-6 - 1.0 x 10-1 M, membrane composition of 30: 60: 7: 3 was 27.71 mV per decade on Hg(II) concentration range of 1.0 x10-6 - 1.0 x10-1 M, and membrane composition of 30: 59: 8: 3 was 28.52 mV per decade on Hg(II) concentration range of 1.0 x10-6 - 1.0 x10-1 M with activity between pH 1.0-3.0. The concentration of interference ions: Zn(II), Cd(II) and Pb(II) in the range of 1.0 x 10-3 - 1.0 x 10-1 M with the ratio of the primary ion to interference ions of 4: 1 gave real effect. As results, selectivities and sensitivities between ISE-Hg(II) and Ionophore DBA218C6 could be determined by PVC-Based Membrane Composition and the effect of Zn(II), Cd(II) and Pb(II) interference ions was observed in the concentration of 1,0 x10-3 - 1,0 x10-1 M. Keywords: membrane composition effect, ionophore DBA218C6, ISE-Hg(II)

Kata kunci

Jaringan kolaborasi para penulis

7 penulis · 21 tautan kepenulisan bersama · 5 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Hasanuddin University
  • Akademi Farmasi Yamasi Makassar
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Nunuk Hariani SoekamtoHasanuddin University1
Hasnah NatsirHasanuddin University1
Rugaiyah Andi ArfahAfiliasi tidak diketahui1
Harningsih KarimAkademi Farmasi Yamasi Makassar1
Nur AuliaHasanuddin University1
Ahyar AhmadHasanuddin University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">THE EFFECT OF PVC-BASED MEMBRANE COMPOSITION AND Zn(II), Cd(II) AND Pb(II) INTERFERING IONS TO Hg(II) ION SELECTIVE ELECTRODE (ISE) PERFORMANCE BY USING DBA218C6 IONOPHORE</dc:title><dc:creator>Abd. Wahid Wahab</dc:creator><dc:subject>potassium tetrakis(4-chlorophenyl)borate</dc:subject><dc:subject>interfering ions</dc:subject><dc:subject>Nernstian slope</dc:subject><dc:subject>potentiometric sensors</dc:subject><dc:subject>heavy metal detection</dc:subject><dc:description xml:lang="en">The effect of PVC (Polyvinylchloride)-Based Membrane Composition to Ion Selective Electrode (ISE)-Hg(II) Performance using Ionophore DBA218C6 (N,N'-Dibenzyl-1,4,10,13-tetraoxa-7,16-diazacyclo octadecane), Plasticizer NPOE (Nitrophenyl Octhyl Ether), Anionic Site KTCPB (Potassium Tetrakis (4-chloro phenyl) borate) have been performed. Membrane compositions used were:(a) PVC (30 mg), NPOE (60 mg), DBA218C6(6 mg) and KTCPB (4 mg); (b) PVC(30 mg), NPOE (60 mg), DBA218C6(7 mg) and KTCPB (3 mg); (c) PVC (30 mg), NPOE (59 mg), DBA218C6 (8 mg) and KTCPB( 3 mg). The concentration range of interference ions Zn(II), Cd(II) and Pb(II) were 1.0 x 10-3 - 1.0 x 10-1 M. ISE-Hg(II) performance for membrane composition of 30 : 60 : 6 : 4 was 26.34 mV per decade (Nernstian Slope value) on Hg(II) concentration range of 1.0x10-6 - 1.0 x 10-1 M , membrane composition of 30 : 60 : 7 : 3 was 27.71 mV per decade on Hg(II) concentration range of 1.0 x10-6 - 1.0 x10-1 M, and membrane composition of 30 : 59 : 8 : 3 was 28.52 mV per decade on Hg(II) concentration range of 1.0 x10-6 - 1.0 x10-1 M with activity between pH 1.0-3.0. The concentration of interference ions : Zn(II), Cd(II) and Pb(II) in the range of 1.0 x 10-3 - 1.0 x 10-1 M with the ratio of the primary ion to interference ions of 4 : 1 gave real effect. As results, selectivities and sensitivities between ISE-Hg(II) and Ionophore DBA218C6 could be determined by PVC-Based Membrane Composition and the effect of Zn(II), Cd(II) and Pb(II) interference ions was observed in the concentration of 1,0 x10-3 - 1,0 x10-1 M. Keywords: membrane composition effect, ionophore DBA218C6, ISE-Hg(II)</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2010-06-13</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>http://doi.org/10.22146/ijc.21768</dc:identifier><dc:identifier>10.22146/ijc.21768</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 6 No 1 (2010); 27-31</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>