The eficiency chromatography of HPTLC plate is better than conventional TLC plate but it more expensive. Due to the higher price of HPTLC plate compare to conventional TLC plate, the application of ";re-used"; HPTLC plate has been tested. After being used for analyzing samples, the plates were developed again with the mobile phase, then dried for 60 min before using for the next measurement. The qualitative chromatography profile showed that ";re-used"; HPTLC plate has less contaminant than new HPTLC plate and the RSD of the precision quantitative testing of the plates reused three times showed a value > 2%. Keywords: reused, HPTLC, TLC, quantitative, qualitative
Jaringan kolaborasi para penulis
5 penulis ·
8 tautan kepenulisan bersama
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">EVALUATION OF RE-USED HPTLC PLATE FOR QUALITATIVE AND QUANTITATIVE ANALYSIS</dc:title><dc:creator>Lestyo Wulandari</dc:creator><dc:subject>HPTLC</dc:subject><dc:subject>quantitative analysis</dc:subject><dc:subject>qualitative analysis</dc:subject><dc:subject>cost reduction</dc:subject><dc:description xml:lang="en">The eficiency chromatography of HPTLC plate is better than conventional TLC plate but it more expensive. Due to the higher price of HPTLC plate compare to conventional TLC plate, the application of ";re-used"; HPTLC plate has been tested. After being used for analyzing samples, the plates were developed again with the mobile phase, then dried for 60 min before using for the next measurement. The qualitative chromatography profile showed that ";re-used"; HPTLC plate has less contaminant than new HPTLC plate and the RSD of the precision quantitative testing of the plates reused three times showed a value > 2%. Keywords: reused, HPTLC, TLC, quantitative, qualitative</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2010-06-15</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>http://doi.org/10.22146/ijc.21743</dc:identifier><dc:identifier>10.22146/ijc.21743</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 6 No 3 (2010); 338-340</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Terindeks
lewat ID karya OpenAlex (record dari sumber OpenAlex)
2 sitasi
Crossref
Terindeks
lewat DOI
1 sitasi
Jumlah menurut tiap indeks pada 19 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref, doaj.
Sitasi artikel ini
APA 7
Wulandari, L. (2010). EVALUATION OF RE-USED HPTLC PLATE FOR QUALITATIVE AND QUANTITATIVE ANALYSIS. Indonesian Journal of Chemistry, 6(3), 338–340. https://doi.org/10.22146/ijc.21743
Salin
IEEE
L. Wulandari, “EVALUATION OF RE-USED HPTLC PLATE FOR QUALITATIVE AND QUANTITATIVE ANALYSIS,” Indonesian Journal of Chemistry, vol. 6, no. 3, pp. 338–340, 2010, doi: 10.22146/ijc.21743.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.