Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Application of Poly(Ethyl Eugenyl Oxyacetate) Compounds as the Ions Carrier for Heavy Metals Separation and Separation of Fe and Ni in Ferronickel Using Liquid Membrane Transport Method

Indonesian Journal of Chemistry · Vol. 22 No. 4 (2022) · hlm. 1002–1002

DOI
10.22146/ijc.72486
ISSN
1411-9420, 2460-1578
Terbit
2022-08-09
Penerbit
Gadjah Mada University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

Poly(ethyl eugenyl oxyacetate) (PEEOA) had been synthesized for separating heavy metals like Fe(III), Cr(III), Cu(II), Ni(II), Co(II), and Pb(II) by liquid membrane transport method. The effects of pH, ion carrier volume, stripping concentration, transport time, and metal ion concentration were investigated to obtain optimum conditions. Experimental results showed that optimum pH occurred at pH 4 for Fe(III) ions and pH 5 for others. Carrier volumes were optimum at 8.5 mL for Fe(III) and Pb(II) ions but 7.5 mL for others. The optimum concentrations of the stripping phase were 2 M for Fe(III) and Cu(II) ions, 1 M for Cr(III), Ni(II), Co(II) ions, and 0.5 M for Pb(II) ion. Transport times were optimum at 36 h for Fe(III) and Co(II) ions and 48 h for others. The optimum metal ion concentrations were 0.25 mM for Fe(III) and Cr(III) ions, while other ions were 0.1 mM. The response of PEEOA to Fe(III) ion was the best with selectivity order, Fe(III) > Cr(III) > Pb(II) > Cu(II) > Ni(II) > Co(II). PEEOA also could separate Fe and Ni in a ferronickel sample whose transport percents were 8.87 and 0.92%, respectively. Hence, PEEOA is reasonably effective as an ions carrier for separating metal ions individually or ionic mixture and also in a ferronickel compound.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 154 tautan kepenulisan bersama · 48 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Gadjah Mada
  • Universitas Halu Oleo
  • Universitas Sembilanbelas November Kolaka
  • Lambung Mangkurat University
  • Indonesia Defense University
  • Saga University
  • Universitas Pattimura
  • Organisasi lain
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Eko Sri KunartiUniversitas Gadjah Mada14
Jumina JuminaUniversitas Gadjah Mada14
Chairil AnwarUniversitas Gadjah Mada14
Bambang RusdiarsoUniversitas Gadjah Mada14
Mudasir MudasirUniversitas Gadjah Mada11
Jumina JuminaUniversitas Gadjah Mada10
Uripto Trisno SantosoLambung Mangkurat University9
Nurul Hidayat AprilitaUniversitas Gadjah Mada8
Triyono TriyonoUniversitas Gadjah Mada7
Hardjono SastrohamidjojoUniversitas Gadjah Mada7
Mustofa MustofaUniversitas Gadjah Mada6
Mustofa MustofaUniversitas Gadjah Mada6
Narsito NarsitoUniversitas Gadjah Mada5
Winarto HaryadiUniversitas Gadjah Mada5
Mudasir MudasirUniversitas Gadjah Mada5
Basuki RahmatIndonesia Defense University5
Indriana KartiniUniversitas Gadjah Mada4
Hanoch Julianus SohilaitUniversitas Pattimura4
Roto RotoUniversitas Gadjah Mada4
Keisuke OhtoSaga University4
Sri SudionoUniversitas Gadjah Mada4
Harno Dwi PranowoUniversitas Gadjah Mada3
Dewi AgustiningsihUniversitas Gadjah Mada3
Suryadi Budi UtomoUniversitas Sebelas Maret3
Ahmad Akhib Ainul YaqinUniversitas Gadjah Mada3
Tutik Dwi WahyuningsihUniversitas Gadjah Mada3
J. Stuart GrossertDalhousie University3
Andi Hairil AlimuddinUniversitas Gadjah Mada3
Maming MamingHasanuddin University3
Choirul AmriPoltekkes Kemenkes Yogyakarta3
Suyanta SuyantaUniversitas Gadjah Mada3
Anjar Purba AsmaraUniversitas Islam Negeri Ar-Raniry2
Alimin AliminUniversitas Halu Oleo2
Dhony HermantoUniversity of Mataram2
Bambang KuswandiUniversitas Jember2

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Application of Poly(Ethyl Eugenyl Oxyacetate) Compounds as the Ions Carrier for Heavy Metals Separation and Separation of Fe and Ni in Ferronickel Using Liquid Membrane Transport Method</dc:title><dc:creator>La Harimu</dc:creator><dc:creator>Sabirin Matsjeh</dc:creator><dc:creator>Dwi Siswanta</dc:creator><dc:creator>Sri Juari Santosa</dc:creator><dc:creator>Muhamad Jalil Baari</dc:creator><dc:subject>ion carriers</dc:subject><dc:subject>liquid membrane transport</dc:subject><dc:subject>heavy metal separation</dc:subject><dc:subject>ferronickel</dc:subject><dc:subject>metal ion selectivity</dc:subject><dc:subject>pH effect</dc:subject><dc:subject>transport time</dc:subject><dc:description xml:lang="en">Poly(ethyl eugenyl oxyacetate) (PEEOA) had been synthesized for separating heavy metals like Fe(III), Cr(III), Cu(II), Ni(II), Co(II), and Pb(II) by liquid membrane transport method. The effects of pH, ion carrier volume, stripping concentration, transport time, and metal ion concentration were investigated to obtain optimum conditions. Experimental results showed that optimum pH occurred at pH 4 for Fe(III) ions and pH 5 for others. Carrier volumes were optimum at 8.5 mL for Fe(III) and Pb(II) ions but 7.5 mL for others. The optimum concentrations of the stripping phase were 2 M for Fe(III) and Cu(II) ions, 1 M for Cr(III), Ni(II), Co(II) ions, and 0.5 M for Pb(II) ion. Transport times were optimum at 36 h for Fe(III) and Co(II) ions and 48 h for others. The optimum metal ion concentrations were 0.25 mM for Fe(III) and Cr(III) ions, while other ions were 0.1 mM. The response of PEEOA to Fe(III) ion was the best with selectivity order, Fe(III) &gt; Cr(III) &gt; Pb(II) &gt; Cu(II) &gt; Ni(II) &gt; Co(II). PEEOA also could separate Fe and Ni in a ferronickel sample whose transport percents were 8.87 and 0.92%, respectively. Hence, PEEOA is reasonably effective as an ions carrier for separating metal ions individually or ionic mixture and also in a ferronickel compound.</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2022-08-09</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.22146/ijc.72486</dc:identifier><dc:identifier>10.22146/ijc.72486</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 22 No 4 (2022); 1002-1002</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:relation>https://jurnal.ugm.ac.id/ijc/article/download/72486/34404</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>