New Design Valve in Flow Injection System for the Determination of Pb(II) in Biological and Environmental Samples

Indonesian Journal of Chemistry · Vol. 23 No. 4 (2023) · hlm. 1129–1129

DOI
10.22146/ijc.83367
ISSN
1411-9420, 2460-1578
Terbit
2023-08-15
Penerbit
Gadjah Mada University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

A strategy to design an injection valve for a streamlined flow injection technique is described as speed and low-cost materials available in the environment for the determination of Pb(II) ion using the organic reagent 4-((4-methoxyphenyl)diazenyl)benzene-1,3-diol at a wavelength of 498 nm. The scope of the study is to find the optimal conditions, including the flow rate of the carrier, the dispersion coefficient, the length of the reaction coil, and the calibration drawing. The results showed that the optimum length of the reaction coil is 20 cm, and the optimum flow rate is 9.1 mL/min, which is equivalent to the pumping rate of 70 F/min. The range of linearity of the study was revealed by a calibration curve of 0.5–27 mg/L, slope = 1.507, correlation coefficient = 0.9995, the limit of quantitative (LOQ) = 0.088 mg/L, and limit of detection (LOD) = 0.026 mg/L. The system under study has a characteristic efficiency. The dispersion coefficient was calculated for concentrations of 10–15 mg/L Pb(II) ion. Furthermore, the accuracy of the flow injection technique in the estimation process was studied and compared with the Flame Atomic Absorption Spectroscopy (FAAS) technique.

Kata kunci

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Sumer
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">New Design Valve in Flow Injection System for the Determination of Pb(II) in Biological and Environmental Samples</dc:title><dc:creator>Thekrayat Joodi Jassim</dc:creator><dc:creator>Raisan Kadhim Taresh</dc:creator><dc:subject>lead(II) determination</dc:subject><dc:subject>flow injection analysis</dc:subject><dc:subject>organic reagents</dc:subject><dc:subject>dispersion coefficient</dc:subject><dc:subject>biological specimen</dc:subject><dc:subject>environmental samples</dc:subject><dc:description xml:lang="en">A strategy to design an injection valve for a streamlined flow injection technique is described as speed and low-cost materials available in the environment for the determination of Pb(II) ion using the organic reagent 4-((4-methoxyphenyl)diazenyl)benzene-1,3-diol at a wavelength of 498 nm. The scope of the study is to find the optimal conditions, including the flow rate of the carrier, the dispersion coefficient, the length of the reaction coil, and the calibration drawing. The results showed that the optimum length of the reaction coil is 20 cm, and the optimum flow rate is 9.1 mL/min, which is equivalent to the pumping rate of 70 F/min. The range of linearity of the study was revealed by a calibration curve of 0.5–27 mg/L, slope = 1.507, correlation coefficient = 0.9995, the limit of quantitative (LOQ) = 0.088 mg/L, and limit of detection (LOD) = 0.026 mg/L. The system under study has a characteristic efficiency. The dispersion coefficient was calculated for concentrations of 10–15 mg/L Pb(II) ion. Furthermore, the accuracy of the flow injection technique in the estimation process was studied and compared with the Flame Atomic Absorption Spectroscopy (FAAS) technique.</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2023-08-15</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>http://dx.doi.org/10.22146/ijc.83367</dc:identifier><dc:identifier>10.22146/ijc.83367</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 23 No 4 (2023); 1129-1129</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:relation>https://jurnal.ugm.ac.id/ijc/article/download/83367/36780</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>