Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Optimization and Validation of High Performance Liquid Chromatographic Fingerprint of Phyllanthus niruri

Indonesian Journal of Chemistry · Vol. 14 No. 2 (2014) · hlm. 168–173

DOI
10.22146/ijc.21254
ISSN
1411-9420, 2460-1578
Terbit
2014-07-25
Penerbit
Gadjah Mada University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

Split-plot mixture-mixture design has been applied for optimization of Phyllanthus niruri chromatographic fingerprint. The design was applied for unreplicated and simultaneous optimization of extraction mixture and chromatographic mobile phase mixture. The whole-plot was extraction solvent contained various combinations of methanol, ethyl acetate and dichloromethane in a simplex centroid with axial design. The sub-plot was reversed phase chromatographic mobile phase in simplex centroid design contained varying proportions of methanol, acetonitrile and acetonitrile:water (55:45 v/v). Each extract was eluted with seven mobile phases of high performance liquid chromatography and detected at 210, 225 and 254 nm. The optimum condition was determined based on the number of peaks. The correlation between extraction solvent, chromatographic mobile phase and number of peak were evaluated with Ordinary Least Square method. The root mean square error of calibration and root mean square error of prediction obtained at 210, 225 and 254 nm were 1.8634 and 4.0076; 2.2220 and 5.2839; 1.5436 and 2.2606, respectively. The optimum condition was obtained when the ethyl acetate extract was eluted with acetonitrile:water (55:45 v/v) and detected at 254 nm. Precision of retention time at optimum condition was excellent, with the relative standard deviation in a range of 0.0698% and 0.3006%.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 114 tautan kepenulisan bersama · 9 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • IPB University
  • Sultan Ageng Tirtayasa University
  • Pakuan University
  • National Research and Innovation Agency
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Mohamad RafiIPB University6
Eti RohaetiIPB University5
I Made SumertajayaIPB University3
Irmanida BatubaraIPB University3
Dyah IswantiniIPB University3
Kusman SadikIPB University2
Utut WidyastutiIPB University2
Nampiah SukarnoIPB University2
Rohani Cinta Badia GintingIPB University2
Rudi HeryantoIPB University2
Utami Dyah SyafitriIPB University2
Farit Mochamad AfendiIPB University2
Budi Riza PutraIPB University2
Dewi Anggraini SeptaningsihIPB University2
Zein Rizky SantosoAfiliasi tidak diketahui1
Anang KurniaIPB University1
Faula ArinaSultan Ageng Tirtayasa University1
Embay RohaetiPakuan University1
Muhammad Edy RizalIPB University1
Anik DjuraidahIPB University1
Nindi PigithaIPB University1
Nunung NurjanahNational Research and Innovation Agency1
Hari WijayantoIPB University1
Fathu NurrahmanIPB University1
INDAHWATI INDAHWATIIPB University1
Titin YuniartyIPB University1
Muhammad Nur AidiIPB University1
Alona DwinataIPB University1
Anang KurniaIPB University1
Nurhidayah NurhidayahIPB University1
Dyah Iswantini PradonoIPB University1
Selvitia UlandariAfiliasi tidak diketahui1
Agus Mohamad SolehIPB University1
Deri SiswaraIPB University1
Nadira Nisa AlwaniIPB University1
Dimas AndriantoIPB University1
Sulistiyani SulistiyaniIPB University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Optimization and Validation of High Performance Liquid Chromatographic Fingerprint of Phyllanthus niruri</dc:title><dc:creator>Wulan Tri Wahyuni</dc:creator><dc:creator>Latifah Kosim Darusman</dc:creator><dc:creator>Aji Hamim Wigena</dc:creator><dc:subject>Phyllanthus niruri</dc:subject><dc:subject>chromatographic fingerprint</dc:subject><dc:subject>extraction solvent optimization</dc:subject><dc:subject>mobile phase optimization</dc:subject><dc:subject>reversed-phase HPLC</dc:subject><dc:subject>simplex centroid design</dc:subject><dc:subject>ethyl acetate extraction</dc:subject><dc:subject>acetonitrile-water mobile phase</dc:subject><dc:subject>herbal medicine quality control</dc:subject><dc:description xml:lang="en">Split-plot mixture-mixture design has been applied for optimization of Phyllanthus niruri chromatographic fingerprint. The design was applied for unreplicated and simultaneous optimization of extraction mixture and chromatographic mobile phase mixture. The whole-plot was extraction solvent contained various combinations of methanol, ethyl acetate and dichloromethane in a simplex centroid with axial design. The sub-plot was reversed phase chromatographic mobile phase in simplex centroid design contained varying proportions of methanol, acetonitrile and acetonitrile:water (55:45 v/v). Each extract was eluted with seven mobile phases of high performance liquid chromatography and detected at 210, 225 and 254 nm. The optimum condition was determined based on the number of peaks. The correlation between extraction solvent, chromatographic mobile phase and number of peak were evaluated with Ordinary Least Square method. The root mean square error of calibration and root mean square error of prediction obtained at 210, 225 and 254 nm were 1.8634 and 4.0076; 2.2220 and 5.2839; 1.5436 and 2.2606, respectively. The optimum condition was obtained when the ethyl acetate extract was eluted with acetonitrile:water (55:45 v/v) and detected at 254 nm. Precision of retention time at optimum condition was excellent, with the relative standard deviation in a range of 0.0698% and 0.3006%.</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2014-07-25</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>http://doi.org/10.22146/ijc.21254</dc:identifier><dc:identifier>10.22146/ijc.21254</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 14 No 2 (2014); 168-173</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>