Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Preparation and Application of Platinum Composite Microelectrode (PCM) for the Routine Analysis of Acetaminophen in Pharmaceutical Products

Indonesian Journal of Chemistry · Vol. 14 No. 2 (2014) · hlm. 109–115

DOI
10.22146/ijc.21246
ISSN
1411-9420, 2460-1578
Terbit
2014-07-25
Penerbit
Gadjah Mada University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

Preparation and application of platinum composite microelectrode (PCM) for the routine analysis of acetaminophen in pharmaceutical products has been carried out. This electrode was prepare by Pt powder and PVC in 4 mL tetrahydrofuran (THF) solvent and swirled flatly to homogeneous followed by drying in an oven at 100 °C for 3 h. The mixture was placed in 0.5 cm diameter stainless steel mould and pressed at 10 ton/cm2. The cyclic voltammetry were performed in a three electrodes system using PCM as a working electrode, an Ag/AgCl (saturated KCl) as reference electrode and platinum wire as the counter electrode. Electroanalysis of acetaminophen was performed in 0.1 M H2SO4 as an electrolyte. The result of the study showed that the correlation of determination using PCM electrode for electroanalysis acetaminophen was R2 = 0.999. Precision, recovery, LOD and LOQ of the PCM towards acetaminophen were found to be 1.04%, 100.54%, 19.52 mg/L and 65.08 mg/L, respectively. As a conclusion, the methods can be used for routine analysis of acetaminophen in pharmaceutical product. Simplicity of sample preparation and use of low cost reagents are the additional benefit of this method.

Kata kunci

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Islamic University of Indonesia
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Preparation and Application of Platinum Composite Microelectrode (PCM) for the Routine Analysis of Acetaminophen in Pharmaceutical Products</dc:title><dc:creator>Riyanto Riyanto</dc:creator><dc:creator>Ahmad Safarudin</dc:creator><dc:subject>paracetamol</dc:subject><dc:subject>electrochemical sensor</dc:subject><dc:subject>pharmaceutical quality control</dc:subject><dc:subject>platinum powder</dc:subject><dc:subject>polyvinyl chloride</dc:subject><dc:subject>electrode fabrication</dc:subject><dc:subject>cyclic voltammetry</dc:subject><dc:subject>low-cost electrodes</dc:subject><dc:description xml:lang="en">Preparation and application of platinum composite microelectrode (PCM) for the routine analysis of acetaminophen in pharmaceutical products has been carried out. This electrode was prepare by Pt powder and PVC in 4 mL tetrahydrofuran (THF) solvent and swirled flatly to homogeneous followed by drying in an oven at 100 °C for 3 h. The mixture was placed in 0.5 cm diameter stainless steel mould and pressed at 10 ton/cm2. The cyclic voltammetry were performed in a three electrodes system using PCM as a working electrode, an Ag/AgCl (saturated KCl) as reference electrode and platinum wire as the counter electrode. Electroanalysis of acetaminophen was performed in 0.1 M H2SO4 as an electrolyte. The result of the study showed that the correlation of determination using PCM electrode for electroanalysis acetaminophen was R2 = 0.999. Precision, recovery, LOD and LOQ of the PCM towards acetaminophen were found to be 1.04%, 100.54%, 19.52 mg/L and 65.08 mg/L, respectively. As a conclusion, the methods can be used for routine analysis of acetaminophen in pharmaceutical product. Simplicity of sample preparation and use of low cost reagents are the additional benefit of this method.</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2014-07-25</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://doi.org/10.22146/ijc.21246</dc:identifier><dc:identifier>10.22146/ijc.21246</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 14 No 2 (2014); 109-115</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>