Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Mesh-Assisted Laser-Induced Plasma Spectroscopy Using Pulse Carbon Dioxide Laser for Analysis of Powder Material by Confining the Powder in a Hole and Employing a Condensation Technique

Indonesian Journal of Chemistry · Vol. 19 No. 3 (2019) · hlm. 606–606

DOI
10.22146/ijc.34778
ISSN
1411-9420, 2460-1578
Terbit
2019-01-03
Penerbit
Gadjah Mada University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

Analysis of impurity in powder samples has been made by using metal-assisted laser-induced plasma spectroscopy utilizing a pulsed CO2 laser. Various powders including food powder, supplement powder, baby powder, and medicine powder were employed as sample materials. Experimentally, the powder sample was tightly put in a hole made on a metal plate and a metal mesh was placed on the powder surface. A pulse CO2 laser (10.6 μm, 1500 mJ) was irradiated on the powder surface passing through the metal mesh. Luminous plasma was induced by mesh just above the mesh when a part of laser energy attacked the mesh. The other part of laser energy impinged the powders and ablated fine particles of powder to the plasma to be atomized and excited. Identification and analysis of elements in powder were successfully conducted. A linear calibration curve of Cu in baby powder has been demonstrated with an intercept zero, certifying that the present technique was a high possibility to be employed for semi-quantitative analysis of elements in powder material. It was proved that by applying the present technique and employing a condensation technique, the detection sensitivity of Cr impurity in the powder sample increased about twenty times compared to the case without condensation. The limit of detection of Cr in rice powder sample was 25 mg/kg. The proposed method was very convenient for the identification and analysis of elements in the powder sample.

Kata kunci

Jaringan kolaborasi para penulis

28 penulis · 75 tautan kepenulisan bersama · 22 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Diponegoro University
  • Universitas Syiah Kuala
  • University of Fukui
  • Udayana University
  • University of Indonesia
  • Binus University
  • Pelita Harapan University
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Tjung Jie LieAfiliasi tidak diketahui2
Koo Hendrik KurniawanAfiliasi tidak diketahui2
Jaka WindartaDiponegoro University2
Iis NurhasanahDiponegoro University2
Sri MurniAfiliasi tidak diketahui1
Ketut Sofjan FirdausiAfiliasi tidak diketahui1
Ria AmitasariAfiliasi tidak diketahui1
Mohamad Infrawan Yulianto IchwanAfiliasi tidak diketahui1
Hery SuyantoUdayana University1
Maria Margaretha SuliyantiUniversity of Indonesia1
Rinda HedwigBinus University1
Marincan PardedePelita Harapan University1
Syahrun Nur AbdulmadjidUniversitas Syiah Kuala1
Yong Inn LeeJeonbuk National University1
Iwao KitazimaUniversity of Fukui1
Tarig ElshaaraniAfiliasi tidak diketahui1
Syarief AlbarDiponegoro University1
Singgih SaptadiDiponegoro University1
Syifa AvicennaDiponegoro University1
Nazli IsmailUniversitas Syiah Kuala1
Rara MitaphonnaUniversitas Syiah Kuala1
Muliadi RamliUniversitas Syiah Kuala1
Tanty FatikasariDiponegoro University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Mesh-Assisted Laser-Induced Plasma Spectroscopy Using Pulse Carbon Dioxide Laser for Analysis of Powder Material by Confining the Powder in a Hole and Employing a Condensation Technique</dc:title><dc:creator>Ali Khumaeni</dc:creator><dc:creator>Asep Yoyo Wardaya</dc:creator><dc:creator>Heri Sugito</dc:creator><dc:creator>Nasrullah Idris</dc:creator><dc:creator>Kiichiro Kagawa</dc:creator><dc:subject>laser-induced breakdown spectroscopy</dc:subject><dc:subject>metal mesh</dc:subject><dc:subject>pulsed CO2 laser</dc:subject><dc:subject>condensation technique</dc:subject><dc:subject>impurity detection</dc:subject><dc:subject>chromium determination</dc:subject><dc:subject>rice powder</dc:subject><dc:subject>baby powder</dc:subject><dc:subject>food powders</dc:subject><dc:description xml:lang="en">Analysis of impurity in powder samples has been made by using metal-assisted laser-induced plasma spectroscopy utilizing a pulsed CO2 laser. Various powders including food powder, supplement powder, baby powder, and medicine powder were employed as sample materials. Experimentally, the powder sample was tightly put in a hole made on a metal plate and a metal mesh was placed on the powder surface. A pulse CO2 laser (10.6 μm, 1500 mJ) was irradiated on the powder surface passing through the metal mesh. Luminous plasma was induced by mesh just above the mesh when a part of laser energy attacked the mesh. The other part of laser energy impinged the powders and ablated fine particles of powder to the plasma to be atomized and excited. Identification and analysis of elements in powder were successfully conducted. A linear calibration curve of Cu in baby powder has been demonstrated with an intercept zero, certifying that the present technique was a high possibility to be employed for semi-quantitative analysis of elements in powder material. It was proved that by applying the present technique and employing a condensation technique, the detection sensitivity of Cr impurity in the powder sample increased about twenty times compared to the case without condensation. The limit of detection of Cr in rice powder sample was 25 mg/kg. The proposed method was very convenient for the identification and analysis of elements in the powder sample.</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2019-01-03</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.22146/ijc.34778</dc:identifier><dc:identifier>10.22146/ijc.34778</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 19 No 3 (2019); 606-606</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:relation>https://jurnal.ugm.ac.id/ijc/article/download/34778/22720</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>