Spectrophotometric Determination of Trace Quantities of Pure Atropine and Pharmaceutical Preparations with SbI42− Ion

Indonesian Journal of Chemistry · Vol. 23 No. 5 (2023) · hlm. 1212–1212

DOI
10.22146/ijc.79010
ISSN
1411-9420, 2460-1578
Terbit
2023-10-16
Penerbit
Gadjah Mada University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

This study aims to estimate a simple, rapid and sensitive method for a trace amount of atropine (ATR) in medicinal compounds. Two approaches were followed to accomplish this aim, i.e., spectrophotometric determination of pure ATR and pharmaceutical preparations using SbI42− ion as a new reagent. The procedure involves the implementation of an ion-association complex with this alkaloid. The resulting complex was extracted and detected spectrophotometrically at 492 nm. Appropriate parameters were investigated, including the ion SbI42− concentration and the pH value of the complex formation. Using chloroform to extract the complex, taking into consideration extraction time and volume of solvent used. The calibration graph is linear in the ranges of 0.5–5.0 × 10−3 M. Precision, accuracy, detection limit, and RSD %, as well as relative standard deviation (n = 5), were calculated. The test sensitivity was 0.013 µg cm−2. Several interference additives were studied by investigating the effect of equal and duplicate quantities of some common excipients on selectivity, such as starch, glucose, lactose, glycerin, and talc. The molar ratio of the SbI42−_ATR was determined. The amount of ATR in the pharmaceutical tablets and eye drop preparation was calculated using Erel at ratios of 2.24 and 2.75%, respectively.

Kata kunci

Jaringan kolaborasi para penulis

3 penulis · 3 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Alrafidain University College
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Spectrophotometric Determination of Trace Quantities of Pure Atropine and Pharmaceutical Preparations with SbI42− Ion</dc:title><dc:creator>Riyadh Hasan Mohammed Ali</dc:creator><dc:creator>Bashar Mudhaffar Abdullah</dc:creator><dc:creator>Rasha Ismail Ahmed</dc:creator><dc:subject>atropine</dc:subject><dc:subject>ion-association complex</dc:subject><dc:subject>trace determination</dc:subject><dc:subject>pharmaceutical preparations</dc:subject><dc:subject>tablets</dc:subject><dc:subject>eye drops</dc:subject><dc:subject>chloroform extraction</dc:subject><dc:subject>alkaloid quantification</dc:subject><dc:subject>pharmaceutical excipients</dc:subject><dc:description xml:lang="en">This study aims to estimate a simple, rapid and sensitive method for a trace amount of atropine (ATR) in medicinal compounds. Two approaches were followed to accomplish this aim, i.e., spectrophotometric determination of pure ATR and pharmaceutical preparations using SbI42− ion as a new reagent. The procedure involves the implementation of an ion-association complex with this alkaloid. The resulting complex was extracted and detected spectrophotometrically at 492 nm. Appropriate parameters were investigated, including the ion SbI42− concentration and the pH value of the complex formation. Using chloroform to extract the complex, taking into consideration extraction time and volume of solvent used. The calibration graph is linear in the ranges of 0.5–5.0 × 10−3 M. Precision, accuracy, detection limit, and RSD %, as well as relative standard deviation (n = 5), were calculated. The test sensitivity was 0.013 µg cm−2. Several interference additives were studied by investigating the effect of equal and duplicate quantities of some common excipients on selectivity, such as starch, glucose, lactose, glycerin, and talc. The molar ratio of the SbI42−_ATR was determined. The amount of ATR in the pharmaceutical tablets and eye drop preparation was calculated using Erel at ratios of 2.24 and 2.75%, respectively.</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2023-10-16</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>http://dx.doi.org/10.22146/ijc.79010</dc:identifier><dc:identifier>10.22146/ijc.79010</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 23 No 5 (2023); 1212-1212</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:relation>https://jurnal.ugm.ac.id/ijc/article/download/79010/36832</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>