Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Spectrophotometry Based Oxidative Coupling Method for Determining Thymol Utilizing a Coupling Agent

Indonesian Journal of Chemistry · Vol. 24 No. 4 (2024) · hlm. 962–962

DOI
10.22146/ijc.85933
ISSN
1411-9420, 2460-1578
Terbit
2024-08-01
Penerbit
Gadjah Mada University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

Developing a spectroscopic approach to assess the medicinal substance thymol was one of the research's objectives. Using an oxidative coupling reaction between thymol solution and N,N-dimethyl-p-phenylenediamine dihydrochloride solution (N,N-DMPPDADH) in alkaline media with potassium periodate as an oxidizing agent, the current technology forms a blue-colored soluble product. The wavelength at which a colored product exhibits maximum absorption is 600 nm. According to Beer's law, the concentration range covered by the approach under review is 1.25–20.00 μg/mL of thymol. The specific molar absorbance value of 10725.71 L/mol cm indicates the method's sensitivity. The Sandell significance value was 0.014 μg/cm2, which represents sensitivity per unit length. The precision of the method is demonstrated to be commendable, and the low relative standard deviation value of 0.16% supports this. This method's accuracy in identifying thymol at such low quantities is demonstrated by its confirmed detection limit of 0.0124 μg/mL. The developed technique has been useful in screening thymol in pharmaceutical products, with mouthwash being the focus of particular attention. Thymol content in real-world samples was accurately determined using the approach, as evidenced by the reported 101.13% recovery rate of thymol in the examined samples.

Kata kunci

Jaringan kolaborasi para penulis

4 penulis · 4 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Tikrit
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Marib Ismail AliUniversity of Tikrit1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Spectrophotometry Based Oxidative Coupling Method for Determining Thymol Utilizing a Coupling Agent</dc:title><dc:creator>Batool Mansour Zayan</dc:creator><dc:creator>Israa Talib Humeidy</dc:creator><dc:creator>Mohammad Salim Abdulaziz</dc:creator><dc:subject>oxidative coupling</dc:subject><dc:subject>potassium periodate</dc:subject><dc:subject>spectrophotometric assay</dc:subject><dc:subject>mouthwash</dc:subject><dc:subject>pharmaceutical quality control</dc:subject><dc:description xml:lang="en">Developing a spectroscopic approach to assess the medicinal substance thymol was one of the research's objectives. Using an oxidative coupling reaction between thymol solution and N,N-dimethyl-p-phenylenediamine dihydrochloride solution (N,N-DMPPDADH) in alkaline media with potassium periodate as an oxidizing agent, the current technology forms a blue-colored soluble product. The wavelength at which a colored product exhibits maximum absorption is 600 nm. According to Beer's law, the concentration range covered by the approach under review is 1.25–20.00 μg/mL of thymol. The specific molar absorbance value of 10725.71 L/mol cm indicates the method's sensitivity. The Sandell significance value was 0.014 μg/cm2, which represents sensitivity per unit length. The precision of the method is demonstrated to be commendable, and the low relative standard deviation value of 0.16% supports this. This method's accuracy in identifying thymol at such low quantities is demonstrated by its confirmed detection limit of 0.0124 μg/mL. The developed technique has been useful in screening thymol in pharmaceutical products, with mouthwash being the focus of particular attention. Thymol content in real-world samples was accurately determined using the approach, as evidenced by the reported 101.13% recovery rate of thymol in the examined samples.</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2024-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>http://dx.doi.org/10.22146/ijc.85933</dc:identifier><dc:identifier>10.22146/ijc.85933</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 24 No 4 (2024); 962-962</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>