Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Graphene Oxide Functionalized Based on Dispersive Solid Phase Extraction of Vitamin B12 Spectrophotometric Determination in Pharmaceutical Samples

Indonesian Journal of Chemistry · Vol. 25 No. 6 (2025) · hlm. 1870–1870

DOI
10.22146/ijc.108465
ISSN
1411-9420, 2460-1578
Terbit
2025-12-01
Penerbit
Gadjah Mada University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

Sample treatment is crucial for detecting target compounds in complex matrices. Recently, graphene oxide (GO) and its composites have garnered attention as sorbents for sample preparation; however, their application in vitamin B12 (VB12) extraction has not been fully explored. In this study, a dispersive solid-phase extraction (D-SPE) method was developed for the spectrophotometric determination of VB12 in pharmaceutical samples using GO, chitosan (CTS), and a GO/CTS composite as sorbents. The materials were characterized using FTIR, XRD, BET, and FESEM. Extraction conditions were optimized, such as pH, sorbent amount, contact time, eluent type and volume, and desorption temperature. Under these conditions, the developed D-SPE method achieved linear calibration ranges of 0.05–15, 0.1–10, and 0.02–10 µg mL−1, with correlation coefficients of 0.9997, 0.9990, and 0.9998, respectively, after extracting VB12 with GO, CTS, and GO/CTS. The limits of quantification were in the range of 1.00–2.09 µg mL−1, with relative standard deviations of less than 0.11% (n = 3). Recoveries in pharmaceutical samples ranged from 95.1 to 112.8% (GO), 91.8 to 95.5% (CTS), and 87.5 to 103.8% (GO/CTS). These results demonstrate that the GO/CTS composite is an efficient and reliable adsorbent for extracting VB12 in pharmaceutical applications.

Kata kunci

Jaringan kolaborasi para penulis

10 penulis · 15 tautan kepenulisan bersama · 4 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Kerbala
  • University of Babylon
  • Iraqi University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Mouyed Khudhair HassanAfiliasi tidak diketahui1
Hasan F. AlesaryUniversity of Kerbala1
Ahmed Saadoon AbbasUniversity of Babylon1
Mohammed Nasser HussainIraqi University1
Hussain Jawad AhmedUniversity of Kerbala1
Hayder Hamied MihsenUniversity of Kerbala1
Ivan Malik ShakerUniversity of Kerbala1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Graphene Oxide Functionalized Based on Dispersive Solid Phase Extraction of Vitamin B12 Spectrophotometric Determination in Pharmaceutical Samples</dc:title><dc:creator>Vian Mohammed Abdulrazzaq</dc:creator><dc:creator>Ahmed Fadhil Khudhair</dc:creator><dc:creator>Thaer M. M. Al-Rammahi</dc:creator><dc:subject>vitamin B12</dc:subject><dc:subject>dispersive solid-phase extraction</dc:subject><dc:subject>graphene oxide</dc:subject><dc:subject>chitosan</dc:subject><dc:subject>sorbents</dc:subject><dc:subject>pharmaceutical analysis</dc:subject><dc:subject>spectrophotometric determination</dc:subject><dc:subject>sample preparation</dc:subject><dc:description xml:lang="en">Sample treatment is crucial for detecting target compounds in complex matrices. Recently, graphene oxide (GO) and its composites have garnered attention as sorbents for sample preparation; however, their application in vitamin B12 (VB12) extraction has not been fully explored. In this study, a dispersive solid-phase extraction (D-SPE) method was developed for the spectrophotometric determination of VB12 in pharmaceutical samples using GO, chitosan (CTS), and a GO/CTS composite as sorbents. The materials were characterized using FTIR, XRD, BET, and FESEM. Extraction conditions were optimized, such as pH, sorbent amount, contact time, eluent type and volume, and desorption temperature. Under these conditions, the developed D-SPE method achieved linear calibration ranges of 0.05–15, 0.1–10, and 0.02–10 µg mL−1, with correlation coefficients of 0.9997, 0.9990, and 0.9998, respectively, after extracting VB12 with GO, CTS, and GO/CTS. The limits of quantification were in the range of 1.00–2.09 µg mL−1, with relative standard deviations of less than 0.11% (n = 3). Recoveries in pharmaceutical samples ranged from 95.1 to 112.8% (GO), 91.8 to 95.5% (CTS), and 87.5 to 103.8% (GO/CTS). These results demonstrate that the GO/CTS composite is an efficient and reliable adsorbent for extracting VB12 in pharmaceutical applications.</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2025-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.22146/ijc.108465</dc:identifier><dc:identifier>10.22146/ijc.108465</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 25 No 6 (2025); 1870-1870</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:relation>https://jurnal.ugm.ac.id/ijc/article/download/108465/42692</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>