Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Preliminary Evaluation of a Passive Sampler Based on Polymeric Inclusion Membranes (PIM) for Measurement of Filterable Reactive Phosphate (FRP) in Freshwater Systems

Indonesian Journal of Chemistry · Vol. 26 No. 5 (2026) · hlm. 1724–1724

DOI
10.22146/ijc.117652
ISSN
1411-9420, 2460-1578
Terbit
2026-09-23
Penerbit
Gadjah Mada University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

Monitoring filterable reactive phosphate (FRP) in aquatic systems is important for eutrophication control. This study evaluated a polymer inclusion membrane (PIM)-passive sampler for FRP measurement in freshwater. The PIM was fabricated by solvent casting using poly(vinyl chloride), Aliquat 336 chloride, and 1-decanol at a 70:20:10 (w/w) ratio and characterized for morphology, elemental distribution, functional groups, wettability, and mechanical properties. The PIM exhibited a smooth, dense, non-porous structure, moderate hydrophilicity, and good mechanical stability, all of which support its suitability for carrier-mediated FRP transport. Laboratory calibration using the kinetic approach gave an FRP permeability coefficient of (6.49 ± 3.39) × 10−7 m s−1 and a sampling rate of (6.15 ± 3.20) × 10−11 m3 s−1. In a preliminary evaluation using field-collected waters exposed under controlled laboratory conditions for 24 h, the sampler yielded time-weighted average FRP concentrations of (0.91 ± 0.05) × 10−5 mol L−1 in river water, (0.34 ± 0.02) × 10−5 mol L−1 in irrigation water, and (0.30 ± 0.01) × 10−5 mol L−1 in fishpond water. The sampler performed best in river water, where matrix interference was lowest. These results indicate that the PIM passive sampler is promising for preliminary operational FRP monitoring in freshwater, although matrix-specific calibration remains necessary.

Kata kunci

Jaringan kolaborasi para penulis

33 penulis · 86 tautan kepenulisan bersama · 28 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Brawijaya
  • Yogyakarta State University
  • Universitas Trunodjoyo Madura
  • Universitas Gadjah Mada
  • Sultan Idris Education University
  • Universitas Negeri Padang
  • Institut Teknologi Sepuluh Nopember
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Azaria Ivana RamadaniUniversity of Brawijaya4
Ulfa AndayaniUniversity of Brawijaya3
Catur RetnaningdyahUniversity of Brawijaya2
Chasan BisriUniversity of Brawijaya2
Ani MulyasuryaniUniversity of Brawijaya2
Hanifah Nur AiniUniversity of Brawijaya2
Adam WiryawanUniversity of Brawijaya2
Anisah Nabilah AzzahUniversity of Brawijaya2
Dede Ardiansyah Takdir Abubakar SanawiUniversity of Brawijaya2
Siti HulwatiUniversity of Brawijaya2
Vita Dwi AnggrainiUniversity of Brawijaya2
Dian SiswantoUniversity of Brawijaya1
Yunin HidayatiUniversitas Trunodjoyo Madura1
Dwi Rakhmatun SulistiyaningrumUniversity of Brawijaya1
Arie SrihardyastutieUniversity of Brawijaya1
Diah MardianaUniversity of Brawijaya1
Layta DiniraUniversity of Brawijaya1
Chandrawati CahyaniUniversity of Brawijaya1
Soebiantoro SoebiantoroUniversity of Brawijaya1
Heni KusumawatiUniversity of Brawijaya1
Faridah YasminUniversity of Brawijaya1
Wahyu O. FajarinaUniversity of Brawijaya1
Rizki SugiriUniversity of Brawijaya1
Suyanta SuyantaUniversitas Gadjah Mada1
Karlinda KarlindaYogyakarta State University1
Sunarto SunartoYogyakarta State University1
Rahadian ZainulUniversitas Negeri Padang1
Fredy KurniawanInstitut Teknologi Sepuluh Nopember1
Illyas Md IsaSultan Idris Education University1
Regina Tutik PadmaningrumYogyakarta State University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764840418, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Preliminary Evaluation of a Passive Sampler Based on Polymeric Inclusion Membranes (PIM) for Measurement of Filterable Reactive Phosphate (FRP) in Freshwater Systems</dc:title><dc:creator>Dina De Jesus Branco</dc:creator><dc:creator>Barlah Rumhayati</dc:creator><dc:creator>Qonitah Fardiyah</dc:creator><dc:subject>polymer inclusion membranes</dc:subject><dc:subject>passive sampling</dc:subject><dc:subject>eutrophication monitoring</dc:subject><dc:subject>freshwater</dc:subject><dc:subject>polyvinyl chloride</dc:subject><dc:subject>1-decanol</dc:subject><dc:subject>membrane permeability</dc:subject><dc:subject>matrix effects</dc:subject><dc:subject>river water</dc:subject><dc:subject>irrigation water</dc:subject><dc:description xml:lang="en">Monitoring filterable reactive phosphate (FRP) in aquatic systems is important for eutrophication control. This study evaluated a polymer inclusion membrane (PIM)-passive sampler for FRP measurement in freshwater. The PIM was fabricated by solvent casting using poly(vinyl chloride), Aliquat 336 chloride, and 1-decanol at a 70:20:10 (w/w) ratio and characterized for morphology, elemental distribution, functional groups, wettability, and mechanical properties. The PIM exhibited a smooth, dense, non-porous structure, moderate hydrophilicity, and good mechanical stability, all of which support its suitability for carrier-mediated FRP transport. Laboratory calibration using the kinetic approach gave an FRP permeability coefficient of (6.49 ± 3.39) × 10−7 m s−1 and a sampling rate of (6.15 ± 3.20) × 10−11 m3 s−1. In a preliminary evaluation using field-collected waters exposed under controlled laboratory conditions for 24 h, the sampler yielded time-weighted average FRP concentrations of (0.91 ± 0.05) × 10−5 mol L−1 in river water, (0.34 ± 0.02) × 10−5 mol L−1 in irrigation water, and (0.30 ± 0.01) × 10−5 mol L−1 in fishpond water. The sampler performed best in river water, where matrix interference was lowest. These results indicate that the PIM passive sampler is promising for preliminary operational FRP monitoring in freshwater, although matrix-specific calibration remains necessary.</dc:description><dc:publisher>Gadjah Mada University</dc:publisher><dc:date>2026-09-23</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.22146/ijc.117652</dc:identifier><dc:identifier>10.22146/ijc.117652</dc:identifier><dc:source>Indonesian Journal of Chemistry; Vol 26 No 5 (2026); 1724-1724</dc:source><dc:source>1411-9420</dc:source><dc:source>2460-1578</dc:source><dc:language>en</dc:language><dc:relation>https://journal.ugm.ac.id/ijc/article/download/117652/44441</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>