Analytical Method for Multi-Tracer Detection of Naphthalene Sulfonates Using HPLC with Fluorescence Detector for Interwell Injection Pattern Analysis in Enhanced Oil Recovery
Naphthalene sulfonic acids (NSAs) are widely used as chemical tracers in reservoir characterization due to their stability, low adsorption, and cost-efficiency. This study presents a high‑performance liquid chromatography (HPLC) method with fluorescence detection for the simultaneous separation and quantification of six NSA tracers (2,6‑NDSA, 1,5‑NDSA, 2,7‑NDSA, 1,6‑NDSA, 1,3,5‑NTSA, and 2‑NSA). The optimized method employed a superficially porous C18 column combined with tetrabutylammonium phosphate and phosphate buffer as ion‑pairing agents. Complete chromatographic resolution was achieved with detection limits ranging from 2.05 to 2.97 µg/L and quantification limits between 6.54–8.90 µg/L. Calibration curves exhibited excellent linearity (R2 ≥ 0.999) across 10–1,000 µg/L. Application of this method in an interwell tracer test demonstrated clear tracer breakthrough behavior, enabling differentiation of injector contributions with recovery values ranging from 2 to 67%. These results confirm that the developed method provides a sensitive, selective, and cost‑effective analytical approach for multi‑tracer monitoring under complex reservoir conditions and supports optimization of EOR strategies.
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.