A Non-Invasive Tool of Cholesterol Level Measurement Prototype Using TCRT 5000 Sensor To Reduce Medical Waste

Bhakti Persada: Jurnal Aplikasi IPTEKS · Vol. 11 No. 2 (2025) · hlm. 46–51

DOI
10.31940/bp.v11i2.46-51
ISSN
2580-5606, 2477-4022
Terbit
2025-10-28
Penerbit
Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali
Bahasa
eng

Abstrak

In this study, we develop non non-invasive tool for cholesterol level measurement using the TCRT 5000 sensor. The tool used Arduino as an electronic prototype and the TCRT 5000 sensor as a detector. The study employs the R&D (Research and Development) design, progressing through the stages of planning, development, and testing of the tool. The development of a non-invasive cholesterol tool can be an innovative tool that is easy, cheap, reduces medical waste, and is not painful (invasive). This development can also help reduce the buildup of non-invasive biodegradable medical waste. The accuracy of the tool developed by the researcher for measuring 14 samples yielded an average error value of 2.42%, with a tool accuracy of 97.58%.

Kata kunci

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ojs2.pnb.ac.id/index.php/BP/oai, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">A Non-Invasive Tool of Cholesterol Level Measurement Prototype Using TCRT 5000 Sensor To Reduce Medical Waste </dc:title>
	<dc:creator>Shofani, Maya</dc:creator>
	<dc:creator>Hardiyanto , Firman </dc:creator>
	<dc:subject xml:lang="en-US">Arduino</dc:subject>
	<dc:subject xml:lang="en-US">Biomedical Sensor</dc:subject>
	<dc:subject xml:lang="en-US">Cholesterol</dc:subject>
	<dc:subject xml:lang="en-US">Non-Invasive</dc:subject>
	<dc:subject xml:lang="en-US">TCRT 5000</dc:subject>
	<dc:description xml:lang="en-US">In this study, we develop non non-invasive tool for cholesterol level measurement using the TCRT 5000 sensor. The tool used Arduino as an electronic prototype and the TCRT 5000 sensor as a detector. The study employs the R&amp;amp;D (Research and Development) design, progressing through the stages of planning, development, and testing of the tool.  The development of a non-invasive cholesterol tool can be an innovative tool that is easy, cheap, reduces medical waste, and is not painful (invasive). This development can also help reduce the buildup of non-invasive biodegradable medical waste. The accuracy of the tool developed by the researcher for measuring 14 samples yielded an average error value of 2.42%, with a tool accuracy of 97.58%.</dc:description>
	<dc:publisher xml:lang="en-US">Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali</dc:publisher>
	<dc:date>2025-10-28</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ojs2.pnb.ac.id/index.php/BP/article/view/2588</dc:identifier>
	<dc:identifier>10.31940/bp.v11i2.46-51</dc:identifier>
	<dc:source xml:lang="en-US">Bhakti persada : jurnal aplikasi Ipteks; Vol. 11 No. 2 (2025): November (2025): Bhakti Persada Jurnal Aplikasi IPTEKS; 46-51</dc:source>
	<dc:source>2580-5606</dc:source>
	<dc:source>2477-4022</dc:source>
	<dc:source>10.31940/bp.v11i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ojs2.pnb.ac.id/index.php/BP/article/view/2588/1215</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2025 Bhakti Persada Jurnal Aplikasi IPTEKS</dc:rights>
	<dc:rights xml:lang="en-US">https://scholar.google.co.id/citations?hl=id&amp;user=Id17GHYAAAAJ&amp;view_op=list_works&amp;sortby=pubdate</dc:rights>
</oai_dc:dc>