Meningkatkan kinerja gardu distribusi SK76 Penyulang Sukasada dalam menangani overblast menggunakan simulasi perangkat lunak ETAP

Journal of Applied Mechanical Engineering and Green Technology · Vol. 3 No. 1 (2022) · hlm. 1–7

DOI
10.31940/jametech.v3i1.1-7
ISSN
2684-8201, 2655-9145
Terbit
2022-03-31
Penerbit
Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali
Bahasa
ind

Abstrak

Inggris

Distribution transformer serves to transform electrical energy from the power source to the customer. In the transformation process there are power losses which of course can reduce the efficiency of the transformer. The relatively high loading on the transformer will cause an increase in power losses, so its efficiency will decrease. The Sukasada Feeder SK76 Distribution Substation with a transformer capacity of 100 kVA supplies 253 customers with an installed power of 273 kVA. Based on the measurements that have been made during the peak load time (WBP), the average percentage of the transformer loading is 99.57% with an efficiency of 98.02%. Referring to the Circular of the Directors of PT. PLN (Persero) No.: 0017.E/DIR/2014, then the transformer has been declared overload (overblast) because the load has exceeded 80%. Efforts that can be made to improve the performance of the transformer include: upgrading the capacity of the transformer, adding additional substations or through network reconfiguration. Based on the trials that have been carried out by the author through the simulation of the ETAP 16.0 software, several results were obtained. If an uprating is carried out with a transformer capacity of 160 kVA, the percentage of loading decreases to around 61.46% with efficiency increasing to about 98.77%. If additional substations are added with a capacity of 50 kVA as well as network reconfiguration by transferring some of the load to another Distribution Substation (SK63), the result is that the percentage of loading is reduced to around 63.17% and efficiency increases to about 98.46%. The simulation results that have been carried out show that this condition has met the provisions/regulations set by PT. PLN (Persero).

Bahasa Indonesia

Transformator distribusi berfungsi untuk mentransformasikan energi listrik dari sumber listrik ke pelanggan. Dalam proses transformasi terdapat rugi-rugi daya yang tentunya dapat menurunkan nilai efisiensi Transformator tersebut. Pembebanan pada transformator yang relatif tinggi akan menyebabkan peningkatan rugi-rugi daya, sehingga efisiensinya akan menurun. Gardu Distribusi SK76 Penyulang Sukasada dengan kapasitas Transformator 100 kVA menyuplai 253 pelanggan dengan daya terpasang 273 kVA. Berdasarkan pengukuran yang telah dilakukan ketika waktu beban puncak (WBP), diperoleh rata-rata persentase pembebanan Transformator tersebut sebesar 99,57% dengan efisiensi 98,02%. Merujuk Surat Edaran Direksi PT. PLN (Persero) No.: 0017.E/DIR/2014, maka Transformator tersebut telah dinyatakan overload (overblast) karena pembebanannya sudah melebihi 80%. Upaya yang dapat dilakukan untuk dapat memperbaiki kinerja Transformator diantaranya adalah: melakukan uprating kapasitas Transformator, penambahan gardu sisipan atau melalui rekonfigurasi jaringan. Berdasarkan uji coba yang telah dilakukan oleh Penulis melalui simulasi perangkat lunak ETAP 16.0, diperoleh beberapa hasil. Apabila dilakukan uprating dengan kapasitas transformator sebesar 160 kVA, maka persentase pembebanannya menurun menjadi sekitar 61,46% dengan efisiensi meningkat menjadi sekitar 98,77%. Apabila dilakukan penambahan gardu sisipan dengan kapasitas 50 kVA maupun dengan rekonfigurasi jaringan melalui pemindahan sebagian beban ke Gardu Distribusi lain (SK63), hasilnya sama-sama dapat menurunkan persentase pembebanan yakni menjadi sekitar 63,17% dan efisiensi meningkat menjadi sekitar 98,46%. Hasil simulasi yang telah dilakukan menunjukan bahwa kondisi ini sudah memenuhi ketentuan/regulasi yang ditetapkan oleh PT. PLN (Persero).

Kata kunci

Jaringan kolaborasi para penulis

32 penulis · 101 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Politeknik Negeri Bali
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Kadek Amerta YasaPoliteknik Negeri Bali3
Anak Agung Ngurah Gde SaptekaPoliteknik Negeri Bali3
I Ketut TaPoliteknik Negeri Bali2
I Wayan SudiarthaPoliteknik Negeri Bali2
I Wayan TeresnaPoliteknik Negeri Bali2
Sabril Prajudith PangestuAfiliasi tidak diketahui1
Made Bagus Astika YasaAfiliasi tidak diketahui1
I Wayan Dimas AriawanAfiliasi tidak diketahui1
I Made PurbawaAfiliasi tidak diketahui1
I Ketut PartiPoliteknik Negeri Bali1
I Gede Guntur SaputraAfiliasi tidak diketahui1
I Made PurbhawaPoliteknik Negeri Bali1
Putu Bagus Aditya MahendraPoliteknik Negeri Bali1
Ngakan Made Ardi MahardikaAfiliasi tidak diketahui1
Gede Rama Weda KusumaAfiliasi tidak diketahui1
I Kadek WirayudaAfiliasi tidak diketahui1
I Made SajayasaAfiliasi tidak diketahui1
Ardy FirmanAfiliasi tidak diketahui1
I Wayan SuwardanaPoliteknik Negeri Bali1
I Ayu Rai WulandariAfiliasi tidak diketahui1
I Made Sumerta YasaPoliteknik Negeri Bali1
Febry Setyacahyana PAfiliasi tidak diketahui1
I Nyoman Gede Arya AstawaPoliteknik Negeri Bali1
Ni Kadek Dessy HariyantiPoliteknik Negeri Bali1
I Made Aryasa WiryawanAfiliasi tidak diketahui1
I Wayan Ryan SutrawanAfiliasi tidak diketahui1
IG Suputra WidharmaAfiliasi tidak diketahui1
Komang Agus WidyatmikaPoliteknik Negeri Bali1
I Wayan Raka ArdanaPoliteknik Negeri Bali1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ojs2.pnb.ac.id/index.php/JAMETECH/oai, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Meningkatkan kinerja gardu distribusi SK76 Penyulang Sukasada dalam menangani overblast menggunakan simulasi perangkat lunak ETAP</dc:title>
	<dc:title xml:lang="id-ID">Meningkatkan kinerja gardu distribusi SK76 Penyulang Sukasada dalam menangani overblast menggunakan simulasi perangkat lunak ETAP </dc:title>
	<dc:creator>Sutawinaya, I Putu</dc:creator>
	<dc:creator>Narottama, Anak Agung Ngurah Made</dc:creator>
	<dc:creator>Pujana, I Gusti Ngurah Ade</dc:creator>
	<dc:subject xml:lang="en-US">Transformer</dc:subject>
	<dc:subject xml:lang="en-US">Substations and Electric Power Distribution Network</dc:subject>
	<dc:subject xml:lang="en-US">software Etap 16.0</dc:subject>
	<dc:subject xml:lang="id-ID">Transformator, Gardu dan Jaringan Distribusi Tenaga Listrik, Perangkat lunak Etap 16.0</dc:subject>
	<dc:description xml:lang="en-US">Distribution transformer serves to transform electrical energy from the power source to the customer. In the transformation process there are power losses which of course can reduce the efficiency of the transformer. The relatively high loading on the transformer will cause an increase in power losses, so its efficiency will decrease. The Sukasada Feeder SK76 Distribution Substation with a transformer capacity of 100 kVA supplies 253 customers with an installed power of 273 kVA. Based on the measurements that have been made during the peak load time (WBP), the average percentage of the transformer loading is 99.57% with an efficiency of 98.02%. Referring to the Circular of the Directors of PT. PLN (Persero) No.: 0017.E/DIR/2014, then the transformer has been declared overload (overblast) because the load has exceeded 80%. Efforts that can be made to improve the performance of the transformer include: upgrading the capacity of the transformer, adding additional substations or through network reconfiguration. Based on the trials that have been carried out by the author through the simulation of the ETAP 16.0 software, several results were obtained. If an uprating is carried out with a transformer capacity of 160 kVA, the percentage of loading decreases to around 61.46% with efficiency increasing to about 98.77%. If additional substations are added with a capacity of 50 kVA as well as network reconfiguration by transferring some of the load to another Distribution Substation (SK63), the result is that the percentage of loading is reduced to around 63.17% and efficiency increases to about 98.46%. The simulation results that have been carried out show that this condition has met the provisions/regulations set by PT. PLN (Persero).</dc:description>
	<dc:description xml:lang="id-ID">Transformator distribusi berfungsi untuk mentransformasikan energi listrik dari sumber listrik ke pelanggan. Dalam proses transformasi terdapat rugi-rugi daya yang tentunya dapat menurunkan nilai efisiensi Transformator tersebut. Pembebanan pada transformator yang relatif tinggi akan menyebabkan peningkatan rugi-rugi daya, sehingga efisiensinya akan menurun. Gardu Distribusi SK76 Penyulang Sukasada dengan kapasitas Transformator 100 kVA menyuplai 253 pelanggan dengan daya terpasang 273 kVA. Berdasarkan pengukuran yang telah dilakukan ketika waktu beban puncak (WBP), diperoleh rata-rata persentase pembebanan Transformator tersebut sebesar 99,57% dengan efisiensi 98,02%. Merujuk Surat Edaran Direksi PT. PLN (Persero) No. : 0017.E/DIR/2014, maka Transformator tersebut&amp;nbsp; telah dinyatakan overload (overblast) karena pembebanannya sudah melebihi 80%. Upaya yang dapat dilakukan untuk dapat memperbaiki kinerja Transformator diantaranya adalah : melakukan uprating kapasitas Transformator, penambahan gardu sisipan atau melalui rekonfigurasi jaringan. Berdasarkan uji coba yang telah dilakukan oleh Penulis&amp;nbsp; melalui simulasi perangkat lunak ETAP 16.0, diperoleh beberapa hasil. Apabila dilakukan uprating dengan kapasitas transformator sebesar 160 kVA, maka persentase pembebanannya menurun menjadi sekitar 61,46% dengan efisiensi meningkat menjadi sekitar 98,77%. Apabila dilakukan penambahan gardu sisipan dengan kapasitas 50 kVA maupun dengan rekonfigurasi jaringan melalui pemindahan sebagian beban ke Gardu Distribusi lain (SK63), hasilnya sama-sama dapat menurunkan persentase pembebanan yakni menjadi sekitar 63,17% dan efisiensi meningkat menjadi sekitar 98,46%. Hasil simulasi yang telah dilakukan menunjukan bahwa kondisi ini sudah memenuhi ketentuan/regulasi yang ditetapkan oleh PT. PLN (Persero).</dc:description>
	<dc:publisher xml:lang="en-US">Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali</dc:publisher>
	<dc:date>2022-03-31</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ojs2.pnb.ac.id/index.php/JAMETECH/article/view/435</dc:identifier>
	<dc:identifier>10.31940/jametech.v3i1.1-7</dc:identifier>
	<dc:source xml:lang="en-US"> Journal of Applied Mechanical Engineering and Green Technology; Vol. 3 No. 1 (2022): March 2022; 1-7</dc:source>
	<dc:source>2684-8201</dc:source>
	<dc:source>2655-9145</dc:source>
	<dc:source>10.31940/jametech.v3i1</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ojs2.pnb.ac.id/index.php/JAMETECH/article/view/435/231</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2022  Journal of Applied Mechanical Engineering and Green Technology</dc:rights>
	<dc:rights xml:lang="en-US">https://scholar.google.com/citations?hl=en&amp;view_op=list_works&amp;authuser=2&amp;gmla=AJsN-F5k01DNihBDbooUvlNxExv-WhpB3DyY0tjGvHKGcOovATy6tUweEZBP3T70BKOQ_1Vu8vDBsjKH91JWXJ8-wUV3JCO9xIjSPLsxXRi8L5d6dn6VJWk&amp;user=PhqmFRYAAAAJ</dc:rights>
</oai_dc:dc>