Evaporative cooling works by sucking air from the environment, then the air is in contact with a pad that is dripping with water on the front side of the blower/fan. Water soaks the pad at the top and the rest of these droplets will fall into the water tank below. Water is circulated from the water tank to the top of the pad with the help of a pump. The cold air coming out of the pad will be blown by the blower/fan into the environment, and the cooling process takes place. Data collection was carried out to obtain the performance of the Evaporative Cooling system made from zeolite by measuring the temperature and RH of the air at several positions, namely outside the conditioned room, after passing through the pad and in the conditioned room. Also recorded is air flow velocity, voltage and current from fans and pumps. Two different water distribution conditions were carried out, namely with the spray pad method and the soaked pad method. Data were collected every 10 minutes for 8 hours. Data were collected for 5 consecutive days. The EC system is an alternative air conditioning system that is environmentally friendly and low energy use. Using a cooling pad material that is environmentally friendly and has the ability to stay wet will make the EC system operate properly. The use of zeolite as a cooling pad material with the ability to absorb and store water is a cooling pad material that needs to be considered. It is still necessary to continue to improve the dimensions and pore structure of the zeolite cooling pad in order to improve the water absorption and storage process.

Bahasa Indonesia

Evaporative cooling bekerja dengan mengalirkan udara lingkungan, selanjutnya udara mengalir bersinggungan pada pad yang telah ditetesi air di sisi depan blower/fan. Air diserap pad di bagian atas dan sisa tetesan air jatuh di water tank. Air dari water tank disirkulasikan menuju sisi atas pad dengan bantuan pompa. Udara dingin keluar pad dihembuskan oleh blower atau fan ke lingkungan sekitarnya, dan terjadilah proses pendinginan. Pengambilan data dilakukan untuk mendapatkan performansi sistem Evaporative Cooling berbahan zeolit dengan mengukur temperatur dan RH udara pada beberapa posisi yaitu di luar ruang yang dikondisikan, saat setelah melewati pad dan di ruang yang dikondisikan. Dilakukan juga pencatatan kecepatan aliran udara, tegangan dan arus dari fan dan pompa. Dua kondisi distribusi air yang berbeda dilakukan yaitu dengan metode pad dispray dan pad direndam. Pengambilan data dilakukan setiap 10 menit selama 8 jam. Data dikumpulkan selama 5 hari berturut-turut. Sistem EC merupakan sistem pengkondisian udara alternative yang ramah lingkungan dan rendah penggunaan energi. Dengan menggunakan bahan cooling pad yang ramah lingkungan dan memiliki kemampuan tetap basah akan membuat sistem EC beroperasi dengan baik. Penggunan zeolit sebagai bahan cooling pad dengan kemampuan penyerapan dan penyimpanan airnya merupakan sebuah bahan cooling pad yang perlu dipertimbangkan. Masih perlu terus dilakukan perbaikan dimensi dan struktur pori cooling pad zeolit agar dapat memperbaiki proses penyerapan dan penyimpanan air.

Kata kunci

Jaringan kolaborasi para penulis

22 penulis · 47 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Politeknik Negeri Bali
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
I Putu Merta AdnyanaPoliteknik Negeri Bali4
I Wayan Adi SubagiaPoliteknik Negeri Bali3
I Wayan TemajaPoliteknik Negeri Bali3
I Made Prasana YogaPoliteknik Negeri Bali2
Made Ery ArsanaPoliteknik Negeri Bali1
Arbyansyah DarmawanPoliteknik Negeri Bali1
I Gede Artha NegaraPoliteknik Negeri Bali1
Daud Simon AnakottaparyPoliteknik Negeri Bali1
Edo KriswidiantoAfiliasi tidak diketahui1
I Wayan TemajaAfiliasi tidak diketahui1
I Wayan Agus Rantia DanaPoliteknik Negeri Bali1
I Made Bagus Panji AdityaPoliteknik Negeri Bali1
I Komang Risky Putra WibawaAfiliasi tidak diketahui1
I Nyoman GunungPoliteknik Negeri Bali1
Ketut BangsePoliteknik Negeri Bali1
I Made Duta IrawanPoliteknik Negeri Bali1
I Made Angga AntaraPoliteknik Negeri Bali1
Ida Bagus Gd WidiantaraAfiliasi tidak diketahui1
I Made Ery ArsanaPoliteknik Negeri Bali1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ojs2.pnb.ac.id/index.php/JAMETECH/oai, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Pengaruh sistem distribusi air pada cooling pad terhadap performansi evaporative cooling</dc:title>
	<dc:title xml:lang="id-ID">Pengaruh sistem distribusi air pada cooling pad terhadap performansi evaporative cooling</dc:title>
	<dc:creator>Dwiana, I Kadek</dc:creator>
	<dc:creator>Midiani, Luh Putu Ike</dc:creator>
	<dc:creator>Tri Putra, I Dewa Gede Agus</dc:creator>
	<dc:subject xml:lang="id-ID">Evaporative cooling</dc:subject>
	<dc:subject xml:lang="id-ID">distribusi air</dc:subject>
	<dc:subject xml:lang="id-ID">cooling pad</dc:subject>
	<dc:subject xml:lang="id-ID">zeolit</dc:subject>
	<dc:subject xml:lang="en-US">Evaporative cooling</dc:subject>
	<dc:subject xml:lang="en-US">water distribution</dc:subject>
	<dc:subject xml:lang="en-US">cooling pad</dc:subject>
	<dc:subject xml:lang="en-US">zeolite</dc:subject>
	<dc:description xml:lang="en-US">Evaporative cooling works by sucking air from the environment, then the air is in contact with a pad that is dripping with water on the front side of the blower/fan. Water soaks the pad at the top and the rest of these droplets will fall into the water tank below. Water is circulated from the water tank to the top of the pad with the help of a pump. The cold air coming out of the pad will be blown by the blower/fan into the environment, and the cooling process takes place. Data collection was carried out to obtain the performance of the Evaporative Cooling system made from zeolite by measuring the temperature and RH of the air at several positions, namely outside the conditioned room, after passing through the pad and in the conditioned room. Also recorded is air flow velocity, voltage and current from fans and pumps. Two different water distribution conditions were carried out, namely with the spray pad method and the soaked pad method. Data were collected every 10 minutes for 8 hours. Data were collected for 5 consecutive days. The EC system is an alternative air conditioning system that is environmentally friendly and low energy use. Using a cooling pad material that is environmentally friendly and has the ability to stay wet will make the EC system operate properly. The use of zeolite as a cooling pad material with the ability to absorb and store water is a cooling pad material that needs to be considered. It is still necessary to continue to improve the dimensions and pore structure of the zeolite cooling pad in order to improve the water absorption and storage process.</dc:description>
	<dc:description xml:lang="id-ID">Evaporative cooling bekerja dengan mengalirkan udara lingkungan, selanjutnya udara mengalir bersinggungan pada pad yang telah ditetesi air di sisi depan blower/fan. Air diserap pad di bagian atas dan sisa tetesan air jatuh di water tank. Air dari water tank disirkulasikan menuju sisi atas pad dengan bantuan pompa. Udara dingin keluar pad dihembuskan oleh blower atau fan ke lingkungan sekitarnya, dan terjadilah proses pendinginan. Pengambilan data dilakukan untuk mendapatkan performansi sistem Evaporative Cooling berbahan zeolit dengan mengukur temperatur dan RH udara pada beberapa posisi yaitu di luar ruang yang dikondisikan, saat setelah melewati pad dan di ruang yang dikondisikan. Dilakukan juga pencatatan kecepatan aliran udara, tegangan dan arus dari fan dan pompa. Dua kondisi distribusi air yang berbeda dilakukan yaitu dengan metode pad dispray dan pad direndam. Pengambilan data dilakukan setiap 10 menit selama 8 jam. Data dikumpulkan selama 5 hari berturut-turut. Sistem EC merupakan sistem pengkondisian udara alternative yang ramah lingkungan dan rendah penggunaan energi. Dengan menggunakan bahan cooling pad yang ramah lingkungan dan memiliki kemampuan tetap basah akan membuat sistem EC beroperasi dengan&amp;nbsp; baik. Penggunan zeolit sebagai bahan cooling pad dengan kemampuan penyerapan dan penyimpanan airnya merupakan sebuah bahan cooling pad yang perlu dipertimbangkan. Masih perlu terus dilakukan perbaikan dimensi dan struktur pori cooling pad zeolit agar dapat memperbaiki proses penyerapan dan penyimpanan air.</dc:description>
	<dc:publisher xml:lang="en-US">Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali</dc:publisher>
	<dc:date>2022-07-31</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ojs2.pnb.ac.id/index.php/JAMETECH/article/view/676</dc:identifier>
	<dc:identifier>10.31940/jametech.v3i2.87-91</dc:identifier>
	<dc:source xml:lang="en-US"> Journal of Applied Mechanical Engineering and Green Technology; Vol. 3 No. 2 (2022): July 2022; 87-91</dc:source>
	<dc:source>2684-8201</dc:source>
	<dc:source>2655-9145</dc:source>
	<dc:source>10.31940/jametech.v3i2</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ojs2.pnb.ac.id/index.php/JAMETECH/article/view/676/361</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2022  Journal of Applied Mechanical Engineering and Green Technology</dc:rights>
	<dc:rights xml:lang="en-US">https://scholar.google.com/citations?hl=en&amp;view_op=list_works&amp;authuser=2&amp;gmla=AJsN-F5k01DNihBDbooUvlNxExv-WhpB3DyY0tjGvHKGcOovATy6tUweEZBP3T70BKOQ_1Vu8vDBsjKH91JWXJ8-wUV3JCO9xIjSPLsxXRi8L5d6dn6VJWk&amp;user=PhqmFRYAAAAJ</dc:rights>
</oai_dc:dc>