Studi Eksperimental Sistem Direct Evaporative Cooling dengan Pemanfaatan Serabut Kelapa sebagai Cooling Pad

Journal of Applied Mechanical Engineering and Green Technology · Vol. 4 No. 2 (2026) · hlm. 88–92

DOI
10.31940/jametech.v4i2.88-92
ISSN
2684-8201, 2655-9145
Terbit
2026-10-22
Penerbit
Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali
Bahasa
ind

Abstrak

Inggris

Conventional vapor-compression cooling systems require relatively high electrical energy consumption; therefore, energy-efficient alternatives such as Direct Evaporative Cooling are needed. This study aims to analyze the performance of a Direct Evaporative Cooling system utilizing coconut fiber cooling pads by observing changes in temperature, relative humidity, heat transfer, cooling effectiveness, power consumption, and the Energy Efficiency Ratio (EER). An experimental method was employed, involving the measurement of water and air temperatures, relative humidity, air velocity, and power consumption using thermocouples, a hygrometer, an anemometer, and a power meter. Data were analyzed using psychrometric charts and heat transfer equations. Test results indicate that under no-load conditions, the system reduced air temperature from 30.1°C to 26.5°C and increased relative humidity from 69.4% to 88.2%, achieving a cooling pad effectiveness of 78% and an EER of 11.7. Under vegetable-load conditions, the system reduced the temperature from 29.8°C to 26.8°C and increased relative humidity from 70.9% to 86%, resulting in an effectiveness of 69%, an EER of 9.54, sensible heat of 0.800 kW, and latent heat of 0.250 kW, with a constant power consumption of 110 Watts. In conclusion, the coconut fiber cooling pad proved to be effective and energy-efficient, demonstrating potential as an economical and environmentally friendly cooling media.

Bahasa Indonesia

Sistem pendingin konvensional berbasis kompresi uap membutuhkan konsumsi energi listrik yang relatif tinggi, sehingga diperlukan alternatif yang lebih hemat energi seperti Direct Evaporative Cooling. Penelitian ini bertujuan untuk menganalisis kinerja sistem Direct Evaporative Cooling menggunakan cooling pad berbahan serabut kelapa berdasarkan perubahan temperatur, kelembapan relatif, perpindahan kalor, efektivitas pendinginan, konsumsi daya, dan Energy Efficiency Ratio (EER). Metode eksperimen diterapkan melalui pengukuran temperatur air dan udara, kelembapan relatif, kecepatan udara, serta konsumsi daya menggunakan Thermocouple, Hygrometer, Anemometer, dan Powermeter. Data dianalisis menggunakan diagram psikrometrik dan persamaan perpindahan panas. Hasil pengujian menunjukkan bahwa pada kondisi tanpa beban, sistem mampu menurunkan temperatur udara dari 30,1°C menjadi 26,5°C dan meningkatkan kelembapan relatif dari 69,4% menjadi 88,2%, menghasilkan efektivitas cooling pad sebesar 78% serta EER 11,7. Pada kondisi beban sayuran, sistem menurunkan temperatur dari 29,8°C menjadi 26,8°C dengan peningkatan kelembapan relatif dari 70,9% menjadi 86%, menghasilkan efektivitas 69%, EER 9,54, kalor sensibel 0,800 kW, dan kalor laten 0,250 kW pada konsumsi daya konstan 110 Watt. Kesimpulannya, cooling pad serabut kelapa terbukti efektif, hemat energi, serta berpotensi menjadi media pendingin yang ekonomis dan ramah lingkungan.

Kata kunci

Jaringan kolaborasi para penulis

33 penulis · 92 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Politeknik Negeri Bali
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
I Wayan Suma WibawaPoliteknik Negeri Bali4
I Kadek DwianaPoliteknik Negeri Bali3
I Made Anom AdiaksaPoliteknik Negeri Bali3
I Wayan Adi SubagiaPoliteknik Negeri Bali2
I Putu Merta AdnyanaPoliteknik Negeri Bali2
I Made Anom AdiaksaPoliteknik Negeri Bali2
I Komang KantunPoliteknik Negeri Bali2
I Wayan TemajaPoliteknik Negeri Bali2
Made Ery ArsanaPoliteknik Negeri Bali1
Arbyansyah DarmawanPoliteknik Negeri Bali1
I Dewa Gede Agus Tri PutraAfiliasi tidak diketahui1
I Gede Artha NegaraPoliteknik Negeri Bali1
Daud Simon AnakottaparyPoliteknik Negeri Bali1
Edo KriswidiantoAfiliasi tidak diketahui1
I Wayan TemajaAfiliasi tidak diketahui1
I Gede Nyoman Suta WaisnawaPoliteknik Negeri Bali1
Made Ardikosa Satrya WibawaAfiliasi tidak diketahui1
I Gst. Ketut AbasanaAfiliasi tidak diketahui1
I Gede Putu AdipratamaAfiliasi tidak diketahui1
I Made Prasana YogaPoliteknik Negeri Bali1
I Nyoman GunungPoliteknik Negeri Bali1
Ketut BangsePoliteknik Negeri Bali1
I Made Duta IrawanPoliteknik Negeri Bali1
I Made Angga AntaraPoliteknik Negeri Bali1
Made Ardikosa Satrya WibawaPoliteknik Negeri Bali1
I Made Agus PutrawanPoliteknik Negeri Bali1
Anak Agung Gede Pradnyana DiputraPoliteknik Negeri Bali1
Ida Bagus Gd WidiantaraAfiliasi tidak diketahui1
I Made Ery ArsanaPoliteknik Negeri Bali1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ojs2.pnb.ac.id/index.php/JAMETECH/oai, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Studi Eksperimental Sistem Direct Evaporative Cooling dengan Pemanfaatan Serabut Kelapa sebagai Cooling Pad</dc:title>
	<dc:title xml:lang="id-ID">Studi Eksperimental Sistem Direct Evaporative Cooling dengan Pemanfaatan Serabut Kelapa sebagai Cooling Pad</dc:title>
	<dc:creator>I Komang Risky Putra Wibawa</dc:creator>
	<dc:creator>Luh Putu Ike Midiani</dc:creator>
	<dc:creator>I Made Bagus Panji Aditya</dc:creator>
	<dc:creator>I Wayan Agus Rantia Dana</dc:creator>
	<dc:subject xml:lang="id-ID">Direct Evaporative Cooling</dc:subject>
	<dc:subject xml:lang="id-ID">coconut fiber</dc:subject>
	<dc:subject xml:lang="id-ID">cooling pad</dc:subject>
	<dc:subject xml:lang="id-ID">system performance</dc:subject>
	<dc:subject xml:lang="id-ID">cooling effectiveness</dc:subject>
	<dc:subject xml:lang="en-US">direct evaporative cooling</dc:subject>
	<dc:subject xml:lang="en-US">coconut fiber</dc:subject>
	<dc:subject xml:lang="en-US">cooling pad</dc:subject>
	<dc:subject xml:lang="en-US">system performance</dc:subject>
	<dc:subject xml:lang="en-US">cooling effectiveness</dc:subject>
	<dc:description xml:lang="en-US">Conventional vapor-compression cooling systems require relatively high electrical energy consumption; therefore, energy-efficient alternatives such as Direct Evaporative Cooling are needed. This study aims to analyze the performance of a Direct Evaporative Cooling system utilizing coconut fiber cooling pads by observing changes in temperature, relative humidity, heat transfer, cooling effectiveness, power consumption, and the Energy Efficiency Ratio (EER). An experimental method was employed, involving the measurement of water and air temperatures, relative humidity, air velocity, and power consumption using thermocouples, a hygrometer, an anemometer, and a power meter. Data were analyzed using psychrometric charts and heat transfer equations. Test results indicate that under no-load conditions, the system reduced air temperature from 30.1°C to 26.5°C and increased relative humidity from 69.4% to 88.2%, achieving a cooling pad effectiveness of 78% and an EER of 11.7. Under vegetable-load conditions, the system reduced the temperature from 29.8°C to 26.8°C and increased relative humidity from 70.9% to 86%, resulting in an effectiveness of 69%, an EER of 9.54, sensible heat of 0.800 kW, and latent heat of 0.250 kW, with a constant power consumption of 110 Watts. In conclusion, the coconut fiber cooling pad proved to be effective and energy-efficient, demonstrating potential as an economical and environmentally friendly cooling media.</dc:description>
	<dc:description xml:lang="id-ID">Sistem pendingin konvensional berbasis kompresi uap membutuhkan konsumsi energi listrik yang relatif tinggi, sehingga diperlukan alternatif yang lebih hemat energi seperti Direct Evaporative Cooling. Penelitian ini bertujuan untuk menganalisis kinerja sistem Direct Evaporative Cooling menggunakan cooling pad berbahan serabut kelapa berdasarkan perubahan temperatur, kelembapan relatif, perpindahan kalor, efektivitas pendinginan, konsumsi daya, dan Energy Efficiency Ratio (EER). Metode eksperimen diterapkan melalui pengukuran temperatur air dan udara, kelembapan relatif, kecepatan udara, serta konsumsi daya menggunakan Thermocouple, Hygrometer, Anemometer, dan Powermeter. Data dianalisis menggunakan diagram psikrometrik dan persamaan perpindahan panas. Hasil pengujian menunjukkan bahwa pada kondisi tanpa beban, sistem mampu menurunkan temperatur udara dari 30,1°C menjadi 26,5°C dan meningkatkan kelembapan relatif dari 69,4% menjadi 88,2%, menghasilkan efektivitas cooling pad sebesar 78% serta EER 11,7. Pada kondisi beban sayuran, sistem menurunkan temperatur dari 29,8°C menjadi 26,8°C dengan peningkatan kelembapan relatif dari 70,9% menjadi 86%, menghasilkan efektivitas 69%, EER 9,54, kalor sensibel 0,800 kW, dan kalor laten 0,250 kW pada konsumsi daya konstan 110 Watt. Kesimpulannya, cooling pad serabut kelapa terbukti efektif, hemat energi, serta berpotensi menjadi media pendingin yang ekonomis dan ramah lingkungan.</dc:description>
	<dc:publisher xml:lang="en-US">Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali</dc:publisher>
	<dc:date>2026-10-22</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ojs2.pnb.ac.id/index.php/JAMETECH/article/view/3504</dc:identifier>
	<dc:identifier>10.31940/jametech.v4i2.88-92</dc:identifier>
	<dc:source xml:lang="en-US"> Journal of Applied Mechanical Engineering and Green Technology; Vol. 4 No. 2 (2026): Oktober; 88-92</dc:source>
	<dc:source>2684-8201</dc:source>
	<dc:source>2655-9145</dc:source>
	<dc:source>10.31940/jametech.v4i2</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ojs2.pnb.ac.id/index.php/JAMETECH/article/view/3504/1602</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026  Journal of Applied Mechanical Engineering and Green Technology</dc:rights>
	<dc:rights xml:lang="en-US">https://scholar.google.com/citations?hl=en&amp;view_op=list_works&amp;authuser=2&amp;gmla=AJsN-F5k01DNihBDbooUvlNxExv-WhpB3DyY0tjGvHKGcOovATy6tUweEZBP3T70BKOQ_1Vu8vDBsjKH91JWXJ8-wUV3JCO9xIjSPLsxXRi8L5d6dn6VJWk&amp;user=PhqmFRYAAAAJ</dc:rights>
</oai_dc:dc>