Possibility analyses of using hydrocarbon R-290 and mixing with R-32 refrigerant to retrofit R-32 domestic split air conditioning

Journal of Applied Mechanical Engineering and Green Technology · Vol. 1 No. 1 (2019) · hlm. 14–19

ISSN
2684-8201, 2655-9145
Terbit
2019-03-31
Penerbit
P3M Politeknik Negeri Bali
Bahasa
eng

Abstrak

Indonesia government's policy to eliminate the use of R-22 refrigerant in air conditioning cooling system will be enforced by 2020. Air cooling equipment manufacturers, especially domestic air conditioners, dominate Indonesia and Asia markets using R-410a and R-32 refrigerants as a replacement to R-22. This study will present the results of experimental studies of retrofit testing on the system of split type domestic AC using R-32 with hydrocarbon refrigerant and Mixing with R-32. The use of hydrocarbons as a refrigerant retrofit is very potential to retrofit R-32 in split type domestic AC without replacement of any part of the system provided that its possibility study has been performed through theoretical and experimental study. An analysis is also done to provide the solution for split AC utilization using R-32 refrigerant retrofitted with hydrocarbon refrigerant. Testing has been done by simply replacing the refrigerant without replacing any component. This experiment uses commonly used ½ Pk split type domestic AC equipment whose equipment consists of a semi-hermetic inverter compressor, condenser and capillary pipe expansion valve in the outdoor unit and an evaporator as a heat exchanger in the indoor unit. Results obtained in preliminary data processing showed that R-32 retrofit with HR-290 hydrocarbon refrigerant and mixing with R-32 deals with improved COP performance from 4.65 to 5.0, 5.47 respectively with reduced energy use.

Jaringan kolaborasi para penulis

14 penulis · 27 tautan kepenulisan bersama · 1 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Politeknik Negeri Bali
  • State University of Malang
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
I Gede Artha NegaraPoliteknik Negeri Bali1
Luh Putu Ike MidianiPoliteknik Negeri Bali1
Daud Simon AnakottaparyPoliteknik Negeri Bali1
Edo KriswidiantoAfiliasi tidak diketahui1
I Nengah ArditaPoliteknik Negeri Bali1
I Gusti Agung Bagus WirajatiAfiliasi tidak diketahui1
SUDIRMAN SUDIRMANState University of Malang1
I.B SukadanaAfiliasi tidak diketahui1
I Nyoman SuamirAfiliasi tidak diketahui1
I Nyoman Gede BaliartaAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ojs.pnb.ac.id/index.php/JAMETECH/oai, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Possibility analyses of using hydrocarbon R-290 and mixing with R-32 refrigerant to retrofit R-32 domestic split air conditioning</dc:title>
	<dc:creator>Ery Arsana, Made</dc:creator>
	<dc:creator>Made Cipta Santosa, I Dewa</dc:creator>
	<dc:creator>Gde Widiantara, Ida Bagus</dc:creator>
	<dc:creator>Temaja, I Wayan</dc:creator>
	<dc:description xml:lang="en-US">Indonesia government's policy to eliminate the use of R-22 refrigerant in air conditioning cooling system will be enforced by 2020. Air cooling equipment manufacturers, especially domestic air conditioners, dominate Indonesia and Asia markets using R-410a and R-32 refrigerants as a replacement to R-22. This study will present the results of experimental studies of retrofit testing on the system of split type domestic AC using R-32 with hydrocarbon refrigerant and Mixing with R-32. The use of hydrocarbons as a refrigerant retrofit is very potential to retrofit R-32 in split type domestic AC without replacement of any part of the system provided that its possibility study has been performed through theoretical and experimental study. An analysis is also done to provide the solution for split AC utilization using R-32 refrigerant retrofitted with hydrocarbon refrigerant. Testing has been done by simply replacing the refrigerant without replacing any component. This experiment uses commonly used ½ Pk split type domestic AC equipment whose equipment consists of a semi-hermetic inverter compressor, condenser and capillary pipe expansion valve in the outdoor unit and an evaporator as a heat exchanger in the indoor unit. Results obtained in preliminary data processing showed that R-32 retrofit with HR-290 hydrocarbon refrigerant and mixing with R-32 deals with improved COP performance from 4.65 to 5.0, 5.47 respectively with reduced energy use.</dc:description>
	<dc:publisher xml:lang="en-US">P3M Politeknik Negeri Bali</dc:publisher>
	<dc:date>2019-03-31</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ojs.pnb.ac.id/index.php/JAMETECH/article/view/1252</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Applied Mechanical Engineering and Green Technology; Vol 1 No 1 (2019): March 2019; 14-19</dc:source>
	<dc:source>2684-8201</dc:source>
	<dc:source>2655-9145</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ojs.pnb.ac.id/index.php/JAMETECH/article/view/1252/995</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2019 Journal of Applied Mechanical Engineering and Green Technology</dc:rights>
</oai_dc:dc>