Melola Discovery

← Melola Discovery

Jurnal SINTA 2

Water Filtration Machine with Monitoring System for Aquades Production and Founding an Optimal Pre- treatment Filter Ratio Before Reverse Osmosis Membrane

Journal of ICT Research and Applications (JICTRA) · Vol. 19 No. 2 (2025) · hlm. 166–190

DOI
10.5614/itbj.ict.res.appl.2025.19.2.4
ISSN
2338-5499, 2337-5787
Terbit
2025-12-31
Penerbit
DRI - ITB
Bahasa
eng

Abstrak

The increasing demand for distilled water (Aquades) in pharmaceutical and medical applications contrasts sharply with the limited quality of municipal water supplies and the high operating costs of commercial Aquades procurement. At the same time, many small-scale facilities still lack integrated systems capable of meeting the Indonesian Ministry of Health standard (Permenkes RI No. 32/2017). Existing research on reverse osmosis (RO) systems largely focuses on membrane or filtration performance, with limited attention to real-time water-quality monitoring and systematic optimization of pre-treatment filters. This study develops an integrated filtration and monitoring system designed to ensure regulatory compliance while optimizing the composition of pre-treatment materials. The system combines silica sand, activated carbon, and zeolite pre-filters with RO, supported by six analog sensors that continuously monitor pH, turbidity, and Total Dissolved Solids before and after filtration. Validation results show high sensor accuracy, with 99.77% for TDS, 98.10% for pH, and 99.97% for turbidity. Among six tested filter compositions, the 25% silica sand-25% activated carbon-50% zeolite configuration achieves the highest average filtration efficiency of 88.96%. These findings demonstrate that optimized pre-treatment combined with real-time monitoring can significantly improve RO performance and support cost-effective Aquades production for medical use.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 7 tautan kepenulisan bersama · 3 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Institut Teknologi Sepuluh Nopember
  • Politeknik Elektronika Negeri Surabaya
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
I Putu Eka Widya PratamaInstitut Teknologi Sepuluh Nopember1
Jasmine Fazrin Widi PutriInstitut Teknologi Sepuluh Nopember1
Ahmad Firyal AdilaPoliteknik Elektronika Negeri Surabaya1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journals.itb.ac.id/index.php/jictra/oai, pertama di-harvest 26 Okt 2026, terakhir terlihat 15 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Water Filtration Machine with Monitoring System for Aquades Production and Founding an Optimal Pre- treatment Filter Ratio Before Reverse Osmosis Membrane</dc:title>
	<dc:creator>Adziimaa, Ahmad Fauzan</dc:creator>
	<dc:creator>Rasyiid, Muhamad Sultan</dc:creator>
	<dc:subject xml:lang="en-US">aquades production</dc:subject>
	<dc:subject xml:lang="en-US">pre-treatment filtration</dc:subject>
	<dc:subject xml:lang="en-US">real-time monitoring</dc:subject>
	<dc:subject xml:lang="en-US">reverse osmosis (RO)</dc:subject>
	<dc:subject xml:lang="en-US">sensor validation</dc:subject>
	<dc:subject xml:lang="en-US">total dissolved solids </dc:subject>
	<dc:subject xml:lang="en-US">water purification system</dc:subject>
	<dc:subject xml:lang="en-US">water quality compliance</dc:subject>
	<dc:description xml:lang="en-US">The increasing demand for distilled water (Aquades) in pharmaceutical and medical applications contrasts sharply with the limited quality of municipal water supplies and the high operating costs of commercial Aquades procurement. At the same time, many small-scale facilities still lack integrated systems capable of meeting the Indonesian Ministry of Health standard (Permenkes RI No. 32/2017). Existing research on reverse osmosis (RO) systems largely focuses on membrane or filtration performance, with limited attention to real-time water-quality monitoring and systematic optimization of pre-treatment filters. This study develops an integrated filtration and monitoring system designed to ensure regulatory compliance while optimizing the composition of pre-treatment materials. The system combines silica sand, activated carbon, and zeolite pre-filters with RO, supported by six analog sensors that continuously monitor pH, turbidity, and Total Dissolved Solids before and after filtration. Validation results show high sensor accuracy, with 99.77% for TDS, 98.10% for pH, and 99.97% for turbidity. Among six tested filter compositions, the 25% silica sand-25% activated carbon-50% zeolite configuration achieves the highest average filtration efficiency of 88.96%. These findings demonstrate that optimized pre-treatment combined with real-time monitoring can significantly improve RO performance and support cost-effective Aquades production for medical use.</dc:description>
	<dc:publisher xml:lang="en-US">DRI - ITB</dc:publisher>
	<dc:date>2025-12-31</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journals.itb.ac.id/index.php/jictra/article/view/24356</dc:identifier>
	<dc:identifier>10.5614/itbj.ict.res.appl.2025.19.2.4</dc:identifier>
	<dc:source xml:lang="en-US">Journal of ICT Research and Applications; Vol. 19 No. 2 (2025); 166-190</dc:source>
	<dc:source>2338-5499</dc:source>
	<dc:source>2337-5787</dc:source>
	<dc:source>10.5614/itbj.ict.res.appl.2025.19.2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journals.itb.ac.id/index.php/jictra/article/view/24356/7286</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026 Journal of ICT Research and Applications</dc:rights>
</oai_dc:dc>