Design an Automatic Transfer Switch for Solar Power Plant
Logic: Jurnal Rancang Bangun dan Teknologi · Vol. 22 No. 1 (2022) · hlm. 9–12
ISSN 2580-5649, 1412-114X
Terbit 2022-03-30
Penerbit Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali
Bahasa eng
Abstrak
This paper discusses the automatic transfer switch (ATS) in solar power plants. ATS is used to transfer the main electrical power to a backup power source (battery). PLN power cannot supply electricity continuously due to non-standard ATS installations, blackouts, disturbances to the generating system, and distribution system. Two ATS systems are proposed to control the switching process of PLN and PLTS automatically using inverter standby mode (ISM) and inverter off mode (IOM). The results of the application of ISM to PLN and PLTS can supply power needs based on switching techniques to avoid equipment damage. While IOM can save battery for inverter power supply.
Jaringan kolaborasi para penulis
12 penulis ·
26 tautan kepenulisan bersama
· 2 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Universitas Pgri Banyuwangi Universitas Muhammadiyah Jember Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://ojs2.pnb.ac.id/index.php/LOGIC/oai, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Design an Automatic Transfer Switch for Solar Power Plant</dc:title>
<dc:creator>Adi Pratama Putra</dc:creator>
<dc:creator>Adi Mulyadi</dc:creator>
<dc:subject xml:lang="en-US">automatic transfer switch</dc:subject>
<dc:subject xml:lang="en-US">solar power plant</dc:subject>
<dc:subject xml:lang="en-US">ISM</dc:subject>
<dc:subject xml:lang="en-US">IOM</dc:subject>
<dc:description xml:lang="en-US">This paper discusses the automatic transfer switch (ATS) in solar power plants. ATS is used to transfer the main electrical power to a backup power source (battery). PLN power cannot supply electricity continuously due to non-standard ATS installations, blackouts, disturbances to the generating system, and distribution system. Two ATS systems are proposed to control the switching process of PLN and PLTS automatically using inverter standby mode (ISM) and inverter off mode (IOM). The results of the application of ISM to PLN and PLTS can supply power needs based on switching techniques to avoid equipment damage. While IOM can save battery for inverter power supply.</dc:description>
<dc:publisher xml:lang="en-US">Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali</dc:publisher>
<dc:date>2022-03-30</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ojs2.pnb.ac.id/index.php/LOGIC/article/view/382</dc:identifier>
<dc:identifier>10.31940/logic.v22i1.9-12</dc:identifier>
<dc:source xml:lang="en-US"> Logic : Jurnal Rancang Bangun dan Teknologi; Vol. 22 No. 1 (2022): March; 9-12</dc:source>
<dc:source>2580-5649</dc:source>
<dc:source>1412-114X</dc:source>
<dc:source>10.31940/logic.v22i1</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ojs2.pnb.ac.id/index.php/LOGIC/article/view/382/212</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2022 Logic : Jurnal Rancang Bangun dan Teknologi</dc:rights>
<dc:rights xml:lang="en-US">https://scholar.google.co.id/citations?user=smBuD3gAAAAJ&hl=id</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 19 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref, doaj.
Sitasi artikel ini
APA 7
Putra, A. P., & Mulyadi, A. (2022). Design an Automatic Transfer Switch for Solar Power Plant. Logic: Jurnal Rancang Bangun dan Teknologi, 22(1), 9–12. https://doi.org/10.31940/logic.v22i1.9-12
Salin
IEEE
A. P. Putra and A. Mulyadi, “Design an Automatic Transfer Switch for Solar Power Plant,” Logic: Jurnal Rancang Bangun dan Teknologi, vol. 22, no. 1, pp. 9–12, 2022, doi: 10.31940/logic.v22i1.9-12.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.