Melola Discovery

← Melola Discovery

Jurnal SINTA 3

The Analysis of the Use of Intercooler on a Multi Stage Cold Storage Simulator Toward the Compressor Work

Logic: Jurnal Rancang Bangun dan Teknologi · Vol. 22 No. 2 (2022) · hlm. 132–139

DOI
10.31940/logic.v22i2.132-139
ISSN
2580-5649, 1412-114X
Terbit
2022-07-30
Penerbit
Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali
Bahasa
eng

Abstrak

Multistage type cold storage is a refrigeration machine required in an industry because it functions to store food products for a long time. Bali, as a world tourist destination, will rely heavily on this cooling system in preparing services for tourists, especially in the food and beverage sector. Multistage type cold storage is designed to reach the evaporator temperature below -30oC thus the used compressor performance must be able to produce maximum refrigeration effect. Two compressors placed in succession or connected in series complete this cold storage system, which is expected to achieve higher operating pressures. The temperature occurring due to the pressure increase on the second compressor will be anticipated by installing an intercooler aiming at preventing excessive heat or over heat during the compression. The extent to which the important role of the intercooler as a stabilizer of operating temperature in this cooling cycle will be shown in its working cycle with a Mollier diagram (P-h diagram). The data obtained during the operation of the multistage type cold storage is then transferred to the P-h diagram of R134A to determine the cycle diagram and the enthalpy which then determines the amount of COP, the maximum temperature achieved by the system, and its energy requirements. The calculation results obtained using the intercooler COP is 1.83, and the maximum temperature achieved is 67oC, and the energy consumption seen from the total entalphy difference due to compression work is 81 kJ/kg. Without using the intercooler, the system’s COP is 1.72 and the maximum temperature achieved is 94.9oC and 86 kJ/kg of energy consumption. The energy required for the operational becomes more eficient and the heat released to the environment is much less, therefore the multistage cold storage with intercooler can be categorized as an eco-friendly technology.

Kata kunci

Jaringan kolaborasi para penulis

6 penulis · 8 tautan kepenulisan bersama · 1 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Politeknik Negeri Bali
  • Kementerian Kesehatan Republik Indonesia
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Ketut BangsePoliteknik Negeri Bali1
I Putu DarmawaPoliteknik Negeri Bali1
I Komang RusmariadiPoliteknik Negeri Bali1
I Made ArsawanPoliteknik Negeri Bali1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ojs2.pnb.ac.id/index.php/LOGIC/oai, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">The Analysis of the Use of Intercooler on a Multi Stage Cold Storage Simulator Toward the Compressor Work</dc:title>
	<dc:creator>I Putu Sastra Negara</dc:creator>
	<dc:creator>Ni Ketut Rusminingsih</dc:creator>
	<dc:subject xml:lang="en-US">compression work</dc:subject>
	<dc:subject xml:lang="en-US">intercoole</dc:subject>
	<dc:subject xml:lang="en-US">performance</dc:subject>
	<dc:description xml:lang="en-US">Multistage type cold storage is a refrigeration machine required in an industry because it functions to store food products for a long time. Bali, as a world tourist destination, will rely heavily on this cooling system in preparing services for tourists, especially in the food and beverage sector. Multistage type cold storage is designed to reach the evaporator temperature below -30oC thus the used compressor performance must be able to produce maximum refrigeration effect. Two compressors placed in succession or connected in series complete this cold storage system, which is expected to achieve higher operating pressures. The temperature occurring due to the pressure increase on the second compressor will be anticipated by installing an intercooler aiming at preventing excessive heat or over heat during the compression. The extent to which the important role of the intercooler as a stabilizer of operating temperature in this cooling cycle will be shown in its working cycle with a Mollier diagram (P-h diagram). The data obtained during the operation of the multistage type cold storage is then transferred to the P-h diagram of R134A to determine the cycle diagram and the enthalpy which then determines the amount of COP, the maximum temperature achieved by the system, and its energy requirements. The calculation results obtained using the intercooler COP is 1.83, and the maximum temperature achieved is 67oC, and the energy consumption seen from the total entalphy difference due to compression work is 81 kJ/kg. Without using the intercooler, the system’s COP is 1.72 and the maximum temperature achieved is 94.9oC and 86 kJ/kg of energy consumption. The energy required for the operational becomes more eficient and the heat released to the environment is much less, therefore the multistage cold storage with intercooler can be categorized as an eco-friendly technology.</dc:description>
	<dc:publisher xml:lang="en-US">Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali</dc:publisher>
	<dc:date>2022-07-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ojs2.pnb.ac.id/index.php/LOGIC/article/view/430</dc:identifier>
	<dc:identifier>10.31940/logic.v22i2.132-139</dc:identifier>
	<dc:source xml:lang="en-US"> Logic : Jurnal Rancang Bangun dan Teknologi; Vol. 22 No. 2 (2022): July; 132-139</dc:source>
	<dc:source>2580-5649</dc:source>
	<dc:source>1412-114X</dc:source>
	<dc:source>10.31940/logic.v22i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ojs2.pnb.ac.id/index.php/LOGIC/article/view/430/319</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2022  Logic : Jurnal Rancang Bangun dan Teknologi</dc:rights>
	<dc:rights xml:lang="en-US">https://scholar.google.co.id/citations?user=smBuD3gAAAAJ&amp;hl=id</dc:rights>
</oai_dc:dc>