Water Conditioning Refrigeration System Design and Construction for Lobster Cultivation
Logic: Jurnal Rancang Bangun dan Teknologi · Vol. 23 No. 1 (2023) · hlm. 1–7
ISSN 2580-5649, 1412-114X
Terbit 2023-03-30
Penerbit Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali
Bahasa eng
Abstrak
This research is to determine the cooling burden of the water conditioning system for lobster conditioning, where water must be conditioned to its temperature by its 21°C conditioning. This device uses steam compression systems precisely by utilizing water conditioning systems to condition water to stay awake at a temperature of 21°C. The method used in this study was to determine the volume of the water tank and its cooling capacity by calculating the load load and calculating the heat load through the walls of the water tank and other heat generated. For lobster cultivation, an air conditioning machine with a capacity of 1/2 PK. From the results of testing the tool for 3 hours, the results of system performance at an evaporation temperature of 15.2 °C and a product temperature of 21 °C obtained a Carnot COP of 7.11, an actual COP of 5.87, and an efficiency of 82.55%. This is in accordance with Design Carnot COP 8, actual COP design of 6.7, and design efficiency of 83%.
Jaringan kolaborasi para penulis
7 penulis ·
13 tautan kepenulisan bersama
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Politeknik Negeri Indramayu Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://ojs2.pnb.ac.id/index.php/LOGIC/oai, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Water Conditioning Refrigeration System Design and Construction for Lobster Cultivation</dc:title>
<dc:creator>Wardika</dc:creator>
<dc:creator>Yudhy Kurniawan</dc:creator>
<dc:creator>Hadi Prayitno</dc:creator>
<dc:creator>Sintya Haula H.</dc:creator>
<dc:subject xml:lang="en-US">Cooling Load</dc:subject>
<dc:subject xml:lang="en-US">COP</dc:subject>
<dc:subject xml:lang="en-US">Efficiency</dc:subject>
<dc:subject xml:lang="en-US">Refrigeration</dc:subject>
<dc:subject xml:lang="en-US">Lobster</dc:subject>
<dc:description xml:lang="en-US">This research is to determine the cooling burden of the water conditioning system for lobster conditioning, where water must be conditioned to its temperature by its 21°C conditioning. This device uses steam compression systems precisely by utilizing water conditioning systems to condition water to stay awake at a temperature of 21°C.&nbsp;The method used in this study was to determine the volume of the water tank and its cooling capacity by calculating the load load and calculating the heat load through the walls of the water tank and other heat generated. For lobster cultivation, an air conditioning machine with a capacity of 1/2 PK. From the results of testing the tool for 3 hours, the results of system performance at an evaporation temperature of 15.2 °C and a product temperature of 21 °C obtained a Carnot COP of 7.11, an actual COP of 5.87, and an efficiency of 82.55%. This is in accordance with Design Carnot COP 8, actual COP design of 6.7, and design efficiency of 83%.</dc:description>
<dc:publisher xml:lang="en-US">Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali</dc:publisher>
<dc:date>2023-03-30</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ojs2.pnb.ac.id/index.php/LOGIC/article/view/725</dc:identifier>
<dc:identifier>10.31940/logic.v23i1.1-7</dc:identifier>
<dc:source xml:lang="en-US"> Logic : Jurnal Rancang Bangun dan Teknologi; Vol. 23 No. 1 (2023): March; 1-7</dc:source>
<dc:source>2580-5649</dc:source>
<dc:source>1412-114X</dc:source>
<dc:source>10.31940/logic.v23i1</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ojs2.pnb.ac.id/index.php/LOGIC/article/view/725/518</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2023 Logic : Jurnal Rancang Bangun dan Teknologi</dc:rights>
<dc:rights xml:lang="en-US">https://scholar.google.co.id/citations?user=smBuD3gAAAAJ&hl=id</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 19 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref, doaj.
Sitasi artikel ini
APA 7
Wardika, Kurniawan, Y., Prayitno, H., & H., S. H. (2023). Water Conditioning Refrigeration System Design and Construction for Lobster Cultivation. Logic: Jurnal Rancang Bangun dan Teknologi, 23(1), 1–7. https://doi.org/10.31940/logic.v23i1.1-7
Salin
IEEE
Wardika, Y. Kurniawan, H. Prayitno, and S. H. H., “Water Conditioning Refrigeration System Design and Construction for Lobster Cultivation,” Logic: Jurnal Rancang Bangun dan Teknologi, vol. 23, no. 1, pp. 1–7, 2023, doi: 10.31940/logic.v23i1.1-7.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.