Melola Discovery

← Melola Discovery

Jurnal SINTA 3

An Analysis of Emission Exhaust Gas on 4-Stroke Engine Based on IOT Gas Analyzer

Logic: Jurnal Rancang Bangun dan Teknologi · Vol. 23 No. 2 (2023) · hlm. 104–110

DOI
10.31940/logic.v23i2.104-110
ISSN
2580-5649, 1412-114X
Terbit
2023-07-31
Penerbit
Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali
Bahasa
eng

Abstrak

According to the Air Quality Live Index (AQLI), Indonesia's air quality has continued to deteriorate in the last two decades, so Indonesia is officially ranked 17th as the country with the worst air quality in the world. This is due to the population explosion in Indonesia causing industrial activity to also increase. The high levels of exhaust emissions in vehicles, of course, requires the need for technology to measure vehicle exhaust gases to reduce the impact of air pollution. However, the procurement of exhaust emission test equipment is still expensive, so only certain class workshops have this tool. In addition, the reading results of the vehicle's OBD (On Board Diagnostic) system are only able to display the condition or reading value of the Lambda sensor because other gas sensors readings such as CO2, HC, and CO cannot be displayed on the OBD reading results. The purpose of this study is to describe the design of the tool and the results of measuring CO and HC levels through the Blynk application. Research methods that use several gas sensors, such as MQ-7 and TGS-2602 (CO gas) and MQ-2 and TGS-2611 (HC gas), are then compared with the measurement results of a standard gas analyzer. The results showed that the MQ-7 value is close to the accuracy at 1000 rpm and 5000 rpm, namely 99.68% and 99.49%, while the level of accuracy at 3000 rpm is 99.37%. The TGS-2602 sensor at 1000 rpm only has the best accuracy and accuracy, namely 99.67% and 99.77%. The level of accuracy of the MQ-2 sensor has the best value at 1000 rpm rotation, which is 95.71% and the level of accuracy has the highest value at 7000 rpm rotation, which is 100%. For the level of accuracy of the TGS-2611 sensor, it has an accuracy level of 1000 rpm rotation of 94.65% and the level of accuracy of the sensor obtains very good values ​​at 1000 rpm, 7000 rpm, and 9000 rpm rotation of 100%.

Kata kunci

Jaringan kolaborasi para penulis

23 penulis · 33 tautan kepenulisan bersama · 6 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • State University of Semarang
  • Politeknik Negeri Malang
  • Yogyakarta State University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Heni Agus PurwantiState University of Semarang1
Nina OktarinaState University of Semarang1
Pujianto PujiantoYogyakarta State University1
Awalya Ma’rifatul JannahAfiliasi tidak diketahui1
Sofrotul NikhmahState University of Semarang1
Suci AstutiState University of Semarang1
Taufan PrihadiniState University of Semarang1
Achmad RifaiState University of Semarang1
Achmad Riqi DzulkurnainState University of Semarang1
Desi LarasatiState University of Semarang1
Prasti PraditasariState University of Semarang1
Ishlah AvianState University of Semarang1
Ayuni Riska PutriState University of Semarang1
Kuat Waluyo JatiState University of Semarang1
Annis Nurfitriana NihayahState University of Semarang1
Ayuntavia AyuntaviaAfiliasi tidak diketahui1
Rima MurtiningsihState University of Semarang1
Sugeng Hadi SusiloPoliteknik Negeri Malang1
Mira Esculenta MartawatiPoliteknik Negeri Malang1
W LulutPoliteknik Negeri Malang1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ojs2.pnb.ac.id/index.php/LOGIC/oai, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">An Analysis of Emission Exhaust Gas on 4-Stroke Engine Based on IOT Gas Analyzer</dc:title>
	<dc:creator>Khatami, Mokhammad </dc:creator>
	<dc:creator>Sujatmiko, Agus </dc:creator>
	<dc:creator>Asrori, Asrori</dc:creator>
	<dc:subject xml:lang="en-US">CO gas</dc:subject>
	<dc:subject xml:lang="en-US">ESP32</dc:subject>
	<dc:subject xml:lang="en-US">Gas Analyzer</dc:subject>
	<dc:subject xml:lang="en-US">HC gas</dc:subject>
	<dc:subject xml:lang="en-US">sensors gas</dc:subject>
	<dc:description xml:lang="en-US">According to the Air Quality Live Index (AQLI), Indonesia's air quality has continued to deteriorate in the last two decades, so Indonesia is officially ranked 17th as the country with the worst air quality in the world. This is due to the population explosion in Indonesia causing industrial activity to also increase. The high levels of exhaust emissions in vehicles, of course, requires the need for technology to measure vehicle exhaust gases to reduce the impact of air pollution. However, the procurement of exhaust emission test equipment is still expensive, so only certain class workshops have this tool. In addition, the reading results of the vehicle's OBD (On Board Diagnostic) system are only able to display the condition or reading value of the Lambda sensor because other gas sensors readings such as CO2, HC, and CO cannot be displayed on the OBD reading results. The purpose of this study is to describe the design of the tool and the results of measuring CO and HC levels through the Blynk application. Research methods that use several gas sensors, such as MQ-7 and TGS-2602 (CO gas) and MQ-2 and TGS-2611 (HC gas), are then compared with the measurement results of a standard gas analyzer. The results showed that the MQ-7 value is close to the accuracy at 1000 rpm and 5000 rpm, namely 99.68% and 99.49%, while the level of accuracy at 3000 rpm is 99.37%. The TGS-2602 sensor at 1000 rpm only has the best accuracy and accuracy, namely 99.67% and 99.77%. The level of accuracy of the MQ-2 sensor has the best value at 1000 rpm rotation, which is 95.71% and the level of accuracy has the highest value at 7000 rpm rotation, which is 100%. For the level of accuracy of the TGS-2611 sensor, it has an accuracy level of 1000 rpm rotation of 94.65% and the level of accuracy of the sensor obtains very good values ​​at 1000 rpm, 7000 rpm, and 9000 rpm rotation of 100%.</dc:description>
	<dc:publisher xml:lang="en-US">Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali</dc:publisher>
	<dc:date>2023-07-31</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ojs2.pnb.ac.id/index.php/LOGIC/article/view/918</dc:identifier>
	<dc:identifier>10.31940/logic.v23i2.104-110</dc:identifier>
	<dc:source xml:lang="en-US"> Logic : Jurnal Rancang Bangun dan Teknologi; Vol. 23 No. 2 (2023): July; 104-110</dc:source>
	<dc:source>2580-5649</dc:source>
	<dc:source>1412-114X</dc:source>
	<dc:source>10.31940/logic.v23i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ojs2.pnb.ac.id/index.php/LOGIC/article/view/918/635</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023  Logic : Jurnal Rancang Bangun dan Teknologi</dc:rights>
	<dc:rights xml:lang="en-US">https://scholar.google.co.id/citations?user=smBuD3gAAAAJ&amp;hl=id</dc:rights>
</oai_dc:dc>