Melola Discovery

← Melola Discovery

Jurnal SINTA 3

Analysis of the Selection and Installation of a Pump for an Overflow Swimming Pool with a Volume of 67 Cubic Meters

Logic: Jurnal Rancang Bangun dan Teknologi · Vol. 23 No. 2 (2023) · hlm. 138–146

DOI
10.31940/logic.v23i2.138-146
ISSN
2580-5649, 1412-114X
Terbit
2023-07-31
Penerbit
Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali
Bahasa
eng

Abstrak

In the swimming pool there is a pump system that is useful for circulating water. Pumps in swimming pools can affect water quality. Dirty water will be cleaned by the filter and will be re-circulated to the swimming pool. The calculations that must be known are the volume of the swimming pool, pump power, flow rate, and the curve of the pump. In order for the selection of a swimming pool pump to be appropriate, the correct calculation must be made so that the pump can provide the best performance for a swimming pool with a volume of 67 cubic meters and is able to circulate swimming pool water 4 times during 12 working hours.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 121 tautan kepenulisan bersama · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Politeknik Negeri Bali
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
I Wayan Suma WibawaPoliteknik Negeri Bali4
I Nyoman SutarnaPoliteknik Negeri Bali4
I Nengah Ludra AntaraPoliteknik Negeri Bali4
I Made RajendraPoliteknik Negeri Bali2
I Wayan SuiryaPoliteknik Negeri Bali2
I Wayan Adi SubagiaPoliteknik Negeri Bali2
I Nyoman SuamirPoliteknik Negeri Bali2
I Nyoman BudiarthanaAfiliasi tidak diketahui2
I Nengah Darma SusilaAfiliasi tidak diketahui2
. SudirmanAfiliasi tidak diketahui2
I Nyoman Gede BaliartaPoliteknik Negeri Bali2
I Wayan TemajaPoliteknik Negeri Bali1
Ida Bagus Gde WidiantaraPoliteknik Negeri Bali1
Made Ery ArsanaPoliteknik Negeri Bali1
M. YusufPoliteknik Negeri Bali1
I Made SudanaPoliteknik Negeri Bali1
NK Dessy HariyantiAfiliasi tidak diketahui1
IGN Suta WaisnawaAfiliasi tidak diketahui1
IA Dwita Krisna AriAfiliasi tidak diketahui1
Ni Kadek Dessy HariyantiAfiliasi tidak diketahui1
Risa Nurin BaitiPoliteknik Negeri Bali1
I Komang KantunPoliteknik Negeri Bali1
I Nyoman SupartaPoliteknik Negeri Bali1
I Wayan Marlon ManagiPoliteknik Negeri Bali1
Anak Agung Gede Pradnyana DiputraPoliteknik Negeri Bali1
Made Ardikosa Satrya WibawaAfiliasi tidak diketahui1
I Made Anom AdiaksaPoliteknik Negeri Bali1
I Made Agus PutrawanPoliteknik Negeri Bali1
I Putu Eka IdrayanaPoliteknik Negeri Bali1
Anak Agung Ngurah Dwi Indra PutraPoliteknik Negeri Bali1
Ketut BangsePoliteknik Negeri Bali1
I Made Anom AdiaksaPoliteknik Negeri Bali1
I Nengah Ludra AntaraAfiliasi tidak diketahui1
I Wayan SuwiryaPoliteknik Negeri Bali1
Ni Wayan Merda Surya DewiPoliteknik Negeri Bali1
I Gusti Bagus Wijaya KusumaAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ojs2.pnb.ac.id/index.php/LOGIC/oai, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Analysis of the Selection and Installation of a Pump for an Overflow Swimming Pool with a Volume of 67 Cubic Meters</dc:title>
	<dc:creator>Achmad Wibolo</dc:creator>
	<dc:creator>I Ketut Suherman</dc:creator>
	<dc:creator>I Dewa Made Pancarana</dc:creator>
	<dc:creator>I Ketut Adi</dc:creator>
	<dc:subject xml:lang="en-US">power</dc:subject>
	<dc:subject xml:lang="en-US">pump</dc:subject>
	<dc:subject xml:lang="en-US">flowrate</dc:subject>
	<dc:subject xml:lang="en-US">swimming pool</dc:subject>
	<dc:description xml:lang="en-US">In the swimming pool there is a pump system that is useful for circulating water. Pumps  in  swimming pools can affect water quality. Dirty  water will be cleaned by the  filter  and  will  be re-circulated to the swimming pool. The calculations  that  must  be  known  are  the  volume  of  the swimming  pool,  pump  power, flow rate, and the curve of  the pump. In  order  for  the  selection of a swimming  pool pump  to be  appropriate, the  correct  calculation  must  be made  so that the pump  can provide  the best  performance for a swimming pool with a volume of 67 cubic meters  and is able to circulate swimming pool water 4 times  during 12 working hours.</dc:description>
	<dc:publisher xml:lang="en-US">Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali</dc:publisher>
	<dc:date>2023-07-31</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ojs2.pnb.ac.id/index.php/LOGIC/article/view/1090</dc:identifier>
	<dc:identifier>10.31940/logic.v23i2.138-146</dc:identifier>
	<dc:source xml:lang="en-US"> Logic : Jurnal Rancang Bangun dan Teknologi; Vol. 23 No. 2 (2023): July; 138-146</dc:source>
	<dc:source>2580-5649</dc:source>
	<dc:source>1412-114X</dc:source>
	<dc:source>10.31940/logic.v23i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ojs2.pnb.ac.id/index.php/LOGIC/article/view/1090/646</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023  Logic : Jurnal Rancang Bangun dan Teknologi</dc:rights>
	<dc:rights xml:lang="en-US">https://scholar.google.co.id/citations?user=smBuD3gAAAAJ&amp;hl=id</dc:rights>
</oai_dc:dc>