Melola Discovery

← Melola Discovery

Jurnal SINTA 3

MATHEMATICAL MODELING AND THERMAL ANALYSIS OF A THERMOELECTRIC COOLER BOX USING A WATER-COOLING BLOCK AND HEATSINK–FAN SYSTEM

Logic: Jurnal Rancang Bangun dan Teknologi · Vol. 26 No. 1 (2026) · hlm. 29–38

DOI
10.31940/logic.v26i1.29-38
ISSN
2580-5649, 1412-114X
Terbit
2026-03-21
Penerbit
Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali
Bahasa
eng

Abstrak

This study presents a mathematical modeling and thermal performance analysis of a Thermoelectric Cooler Box (TEC) equipped with two hot-side heat rejection systems: a Water Cooling Block (WCB) and a Heatsink–Fan (HSF). Thermoelectric cooling offers an environmentally friendly alternative to vapor-compression refrigeration because it operates without refrigerants and requires only low-voltage DC power. The objective of this work is to evaluate the influence of electrical current on temperature distribution, cooling capacity (Qc), and the coefficient of performance (COP) of a TEC1-12706 module under both cooling configurations. The mathematical model is formulated based on the energy balance between the cold and hot sides, incorporating the Peltier effect, thermal conduction, and Joule heating losses. Numerical simulations were performed in Python for currents ranging from 1 to 7 A. The results show that the WCB reduces the hot-side temperature (Tₕ) by 6–8 °C compared with the HSF, indicating superior heat rejection. However, the HSF system achieves a slightly higher COP (about 5–7%) due to the lower cold-side temperature (Tc) obtained in the WCB configuration, which reduces the effective Peltier cooling term. The maximum COP for both systems occurs at 3–4 A, corresponding to a temperature difference (ΔT) of approximately 28 °C. Although the cooling capacity of the WCB is slightly lower (<10%) due to increased back-conduction, it offers better thermal stability and long-term performance consistency. Overall, the developed mathematical model accurately represents the TEC’s thermal behavior and provides a reliable foundation for optimizing water-cooled thermoelectric designs.

Kata kunci

Jaringan kolaborasi para penulis

36 penulis · 121 tautan kepenulisan bersama · 10 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Politeknik Negeri Bali
  • Universitas Pembangunan Nasional Veteran Jakarta
  • Muhammadiyah University of Surakarta
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
James JulianUniversitas Pembangunan Nasional Veteran Jakarta3
I Made RastaAfiliasi tidak diketahui3
I Nyoman SuamirAfiliasi tidak diketahui3
Fitri WahyuniUniversitas Pembangunan Nasional Veteran Jakarta2
I Wayan Adi SubagiaPoliteknik Negeri Bali2
Riki Hendra PurbaUniversitas Pembangunan Nasional Veteran Jakarta2
Elvi ErmadaniUniversitas Pembangunan Nasional Veteran Jakarta2
Made Ery ArsanaPoliteknik Negeri Bali2
I Dewa Made Cipta SantosaPoliteknik Negeri Bali2
I Gusti Agung Bagus WirajatiPoliteknik Negeri Bali2
I Nyoman Agus Adi SaputraPoliteknik Negeri Bali2
Annastya Bagas DewantaraUniversitas Pembangunan Nasional Veteran Jakarta1
Nandy PutraAfiliasi tidak diketahui1
I Gusti Ketut PujaAfiliasi tidak diketahui1
Ngafwan NgafwanMuhammadiyah University of Surakarta1
I Wayan TemajaPoliteknik Negeri Bali1
Ida Ayu Anom ArsaniPoliteknik Negeri Bali1
I Gede Artha NegaraPoliteknik Negeri Bali1
I Nyoman Gede BaliartaPoliteknik Negeri Bali1
Komang Widhi WidanthaPoliteknik Negeri Bali1
Luh Putu Ike MidianiAfiliasi tidak diketahui1
I Gusti Agung Oka SudiadnyaniAfiliasi tidak diketahui1
I Dewa Made SusilaPoliteknik Negeri Bali1
I Wayan SuiryaPoliteknik Negeri Bali1
I Made RastaPoliteknik Negeri Bali1
I Gusti Ketut PujaPoliteknik Negeri Bali1
Putu Wijaya SunuPoliteknik Negeri Bali1
Anggie Topan WijayaUniversitas Pembangunan Nasional Veteran Jakarta1
Fathin MadhudhuAfiliasi tidak diketahui1
Fathin Muhammad MahdhudhuUniversitas Pembangunan Nasional Veteran Jakarta1
Bima Rakha AdhitamaUniversitas Pembangunan Nasional Veteran Jakarta1
Fitri WahyuniUniversitas Pembangunan Nasional Veteran Jakarta1
DaudSimon AnnakotaparyAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ojs2.pnb.ac.id/index.php/LOGIC/oai, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">MATHEMATICAL MODELING AND THERMAL ANALYSIS OF A THERMOELECTRIC COOLER BOX USING A WATER-COOLING BLOCK AND HEATSINK–FAN SYSTEM</dc:title>
	<dc:creator>Saputra, I Nyoman Agus Adi</dc:creator>
	<dc:creator>Winarta, Adi</dc:creator>
	<dc:creator>Sutina, I Wayan</dc:creator>
	<dc:subject xml:lang="en-US">Thermoelectric</dc:subject>
	<dc:subject xml:lang="en-US">Water cooling block</dc:subject>
	<dc:subject xml:lang="en-US">Heatsink–Fan</dc:subject>
	<dc:subject xml:lang="en-US">coefficient of performance</dc:subject>
	<dc:subject xml:lang="en-US">Mathematical Modeling</dc:subject>
	<dc:description xml:lang="en-US">This study presents a mathematical modeling and thermal performance analysis of a Thermoelectric Cooler Box (TEC) equipped with two hot-side heat rejection systems: a Water Cooling Block (WCB) and a Heatsink–Fan (HSF). Thermoelectric cooling offers an environmentally friendly alternative to vapor-compression refrigeration because it operates without refrigerants and requires only low-voltage DC power. The objective of this work is to evaluate the influence of electrical current on temperature distribution, cooling capacity (Qc), and the coefficient of performance (COP) of a TEC1-12706 module under both cooling configurations. The mathematical model is formulated based on the energy balance between the cold and hot sides, incorporating the Peltier effect, thermal conduction, and Joule heating losses. Numerical simulations were performed in Python for currents ranging from 1 to 7 A.&amp;nbsp;The results show that the WCB reduces the hot-side temperature (Tₕ) by 6–8 °C compared with the HSF, indicating superior heat rejection. However, the HSF system achieves a slightly higher COP (about 5–7%) due to the lower cold-side temperature (Tc) obtained in the WCB configuration, which reduces the effective Peltier cooling term. The maximum COP for both systems occurs at 3–4 A, corresponding to a temperature difference (ΔT) of approximately 28 °C. Although the cooling capacity of the WCB is slightly lower (&amp;lt;10%) due to increased back-conduction, it offers better thermal stability and long-term performance consistency.&amp;nbsp;Overall, the developed mathematical model accurately represents the TEC’s thermal behavior and provides a reliable foundation for optimizing water-cooled thermoelectric designs.</dc:description>
	<dc:publisher xml:lang="en-US">Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali</dc:publisher>
	<dc:date>2026-03-21</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ojs2.pnb.ac.id/index.php/LOGIC/article/view/2825</dc:identifier>
	<dc:identifier>10.31940/logic.v26i1.29-38</dc:identifier>
	<dc:source xml:lang="en-US"> Logic : Jurnal Rancang Bangun dan Teknologi; Vol. 26 No. 1 (2026): March; 29-38</dc:source>
	<dc:source>2580-5649</dc:source>
	<dc:source>1412-114X</dc:source>
	<dc:source>10.31940/logic.v26i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ojs2.pnb.ac.id/index.php/LOGIC/article/view/2825/1442</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026 I Nyoman Agus Adi Saputra, Adi Winarta, I Wayan Sutina</dc:rights>
	<dc:rights xml:lang="en-US">https://scholar.google.co.id/citations?user=smBuD3gAAAAJ&amp;hl=id</dc:rights>
</oai_dc:dc>