Numerical Analysis of Outlet Number Effects on Temperature Distribution in a Briquette Oven Using CFD

Logic: Jurnal Rancang Bangun dan Teknologi · Vol. 26 No. 2 (2026) · hlm. 157–166

DOI
10.31940/logic.v26i2.157-166
ISSN
2580-5649, 1412-114X
Terbit
2026-07-31
Penerbit
Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali
Bahasa
eng

Abstrak

The performance of briquette drying systems is strongly influenced by airflow distribution and thermal uniformity within the drying chamber, which are governed by outlet configuration and internal flow patterns. However, limited studies have systematically quantified the effect of exhaust outlet arrangements on the coupled heat transfer and fluid flow behavior in industrial-scale briquette ovens. This study aims to numerically investigate the influence of single-, double-, and four-outlet configurations on airflow characteristics, temperature distribution, and overall thermal performance of a briquette drying oven. A three-dimensional geometric model representing the combustion chamber, drying chamber, and briquette racks was developed and analyzed using Computational Fluid Dynamics (CFD). Steady-state simulations were performed in ANSYS Fluent employing the standard k–ε turbulence model, with air properties, inlet velocity (9.97 m/s), and thermal boundary conditions defined based on operational data. The results reveal that outlet configuration significantly affects flow recirculation intensity and temperature uniformity across the briquette racks. The four-outlet configuration produced the most homogeneous airflow distribution and reduced thermal gradients, thereby enhancing convective heat transfer effectiveness compared to single- and double-outlet designs. Conversely, the single-outlet case exhibited pronounced recirculation zones and localized temperature variations, potentially leading to uneven drying. These findings demonstrate that optimizing outlet arrangement is a critical design parameter for improving drying efficiency and energy utilization in briquette oven systems, providing a validated numerical framework for future thermal system optimization.

Kata kunci

Jaringan kolaborasi para penulis

6 penulis · 9 tautan kepenulisan bersama · 5 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Muhammadiyah Gresik
  • Politeknik Negeri Malang
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Siti Duratun Nasiqiati RosadyPoliteknik Negeri Malang1
Ilham Arifin PahlawanUniversitas Muhammadiyah Gresik1
Rilo Chandra MuhamadinUniversitas Muhammadiyah Gresik1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ojs2.pnb.ac.id/index.php/LOGIC/oai, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Numerical Analysis of Outlet Number Effects on Temperature Distribution in a Briquette Oven Using CFD</dc:title>
	<dc:creator>Ningtyas, Alviani Hesthi Permata</dc:creator>
	<dc:creator>Rosady, Siti Duratun</dc:creator>
	<dc:creator>Muhammad Wildanus Sholih</dc:creator>
	<dc:subject xml:lang="en-US">Computational Fluid Dynamics,</dc:subject>
	<dc:subject xml:lang="en-US">Outlet Configuration</dc:subject>
	<dc:subject xml:lang="en-US">Heat Transfer</dc:subject>
	<dc:description xml:lang="en-US">The performance of briquette drying systems is strongly influenced by airflow distribution and thermal uniformity within the drying chamber, which are governed by outlet configuration and internal flow patterns. However, limited studies have systematically quantified the effect of exhaust outlet arrangements on the coupled heat transfer and fluid flow behavior in industrial-scale briquette ovens. This study aims to numerically investigate the influence of single-, double-, and four-outlet configurations on airflow characteristics, temperature distribution, and overall thermal performance of a briquette drying oven. A three-dimensional geometric model representing the combustion chamber, drying chamber, and briquette racks was developed and analyzed using Computational Fluid Dynamics (CFD). Steady-state simulations were performed in ANSYS Fluent employing the standard k–ε turbulence model, with air properties, inlet velocity (9.97 m/s), and thermal boundary conditions defined based on operational data. The results reveal that outlet configuration significantly affects flow recirculation intensity and temperature uniformity across the briquette racks. The four-outlet configuration produced the most homogeneous airflow distribution and reduced thermal gradients, thereby enhancing convective heat transfer effectiveness compared to single- and double-outlet designs. Conversely, the single-outlet case exhibited pronounced recirculation zones and localized temperature variations, potentially leading to uneven drying. These findings demonstrate that optimizing outlet arrangement is a critical design parameter for improving drying efficiency and energy utilization in briquette oven systems, providing a validated numerical framework for future thermal system optimization.</dc:description>
	<dc:publisher xml:lang="en-US">Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali</dc:publisher>
	<dc:date>2026-07-31</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ojs2.pnb.ac.id/index.php/LOGIC/article/view/3218</dc:identifier>
	<dc:identifier>10.31940/logic.v26i2.157-166</dc:identifier>
	<dc:source xml:lang="en-US"> Logic : Jurnal Rancang Bangun dan Teknologi; Vol. 26 No. 2 (2026): July; 157-166</dc:source>
	<dc:source>2580-5649</dc:source>
	<dc:source>1412-114X</dc:source>
	<dc:source>10.31940/logic.v26i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ojs2.pnb.ac.id/index.php/LOGIC/article/view/3218/1544</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026 Alviani Hesthi Permata Ningtyas, Siti Duratun Rosady, Muhammad Wildanus Sholih</dc:rights>
	<dc:rights xml:lang="en-US">https://scholar.google.co.id/citations?user=smBuD3gAAAAJ&amp;hl=id</dc:rights>
</oai_dc:dc>