Comparison Between the BOQ of Conventional and BIM Method on BPJS Building in Central Jakarta

Logic: Jurnal Rancang Bangun dan Teknologi · Vol. 21 No. 1 (2021) · hlm. 31–39

DOI
10.31940/logic.v21i1.2260
ISSN
2580-5649, 1412-114X
Terbit
2021-03-30
Penerbit
Pusat Penelitian dan Pengabdian kepada Masyarakat (P3M) Politeknik Negeri Bali
Bahasa
eng

Abstrak

In the construction planning process, the calculation of the quantity of each project work was packaged in a Bill of Quantity (BoQ) to complete the project and greatly affected the continuity of the entire construction construction process. With advances in technology in the world of construction, it could simplify planning in built a building and could increased the accuracy of calculations without using assumptions that could increased the volume of work. One of the results of current technological advances was the creation of the Building Information Modeling (BIM) method, a method that was able to simulate all information in a development project into a 3-dimensional model. Currently the use of the BIM method in Indonesia was still limited so that in this research, the aim was to determine the effectiveness of the use of BIM on the accuracy calculation of the volume of the BoQ and to know the percentage comparison. The building project that was used as a comparison was a building with the middle rise building category, namely the Central Jakarta BPJS Building. Based on the research conducted, it was found that the difference between conventional and BIM results on pilecap components was 5%, column 6%, beam 35%, floor slabs 2%, stairs 22%, ceiling 2.26% floor coverings 14% lower than conventional calculations but for the wall component the BIM calculation is 0.78% greater than the conventional calculation. So that the total percentage ratio is 10%, thus this proves that the use of the BIM method in calculating quantity was effective in terms of calculation accuracy.

Jaringan kolaborasi para penulis

10 penulis · 19 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Jakarta State Polytechnic
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Jonathan SaputraJakarta State Polytechnic3
Anis RosyidahJakarta State Polytechnic2
Oky Bima PutraJakarta State Polytechnic1
Ilham Dwiputra RamadhanJakarta State Polytechnic1
Tree Irma DindaJakarta State Polytechnic1
Mayda PahinggisJakarta State Polytechnic1
Alvin DunaufalJakarta State Polytechnic1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ojs.pnb.ac.id/index.php/LOGIC/oai, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Comparison Between the BOQ of Conventional and BIM Method on BPJS Building in Central Jakarta</dc:title>
	<dc:creator>Akbar, Mutia Hanuun Ufaira</dc:creator>
	<dc:creator>Sucita, I Ketut</dc:creator>
	<dc:creator>Yanuarini, Erlina</dc:creator>
	<dc:description xml:lang="en-US">In the construction planning process, the calculation of the quantity of each project work was packaged in a Bill of Quantity (BoQ) to complete the project and greatly affected the continuity of the entire construction construction process. With advances in technology in the world of construction, it could simplify planning in built a building and could increased the accuracy of calculations without using assumptions that could increased the volume of work. One of the results of current technological advances was the creation of the Building Information Modeling (BIM) method, a method that was able to simulate all information in a development project into a 3-dimensional model. Currently the use of the BIM method in Indonesia was still limited so that in this research, the aim was to determine the effectiveness of the use of BIM on the accuracy calculation of the volume of the BoQ and to know the percentage comparison. The building project that was used as a comparison was a building with the middle rise building category, namely the Central Jakarta BPJS Building. Based on the research conducted, it was found that the difference between conventional and BIM results on pilecap components was 5%, column 6%, beam 35%, floor slabs 2%, stairs 22%, ceiling 2.26% floor coverings 14% lower than conventional calculations but for the wall component the BIM calculation is 0.78% greater than the conventional calculation. So that the total percentage ratio is 10%, thus this proves that the use of the BIM method in calculating quantity was effective in terms of calculation accuracy.</dc:description>
	<dc:publisher xml:lang="en-US">Pusat Penelitian dan Pengabdian kepada Masyarakat (P3M) Politeknik Negeri Bali</dc:publisher>
	<dc:date>2021-03-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ojs.pnb.ac.id/index.php/LOGIC/article/view/2260</dc:identifier>
	<dc:identifier>10.31940/logic.v21i1.2260</dc:identifier>
	<dc:source xml:lang="en-US">Logic : Jurnal Rancang Bangun dan Teknologi; Vol 21 No 1 (2021): March; 31-39</dc:source>
	<dc:source>2580-5649</dc:source>
	<dc:source>1412-114X</dc:source>
	<dc:source>10.31940/logic.v21i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ojs.pnb.ac.id/index.php/LOGIC/article/view/2260/1662</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 Logic : Jurnal Rancang Bangun dan Teknologi</dc:rights>
</oai_dc:dc>