Performance Insulator Cover Type: YSL-70-AP Post Voltage Break Down Test

Logic: Jurnal Rancang Bangun dan Teknologi · Vol. 20 No. 2 (2020) · hlm. 95–98

DOI
10.31940/logic.v20i2.1784
ISSN
2580-5649, 1412-114X
Terbit
2020-07-30
Penerbit
Pusat Penelitian dan Pengabdian kepada Masyarakat (P3M) Politeknik Negeri Bali
Bahasa
eng

Abstrak

Electrical energy affect to economic, electrical energy consumption will increase and decrease likely economics. In this globalization era, electricity consumption was increased trend yearly since industrialization era. The reliability Electrical energy is very important for economic growth. The lower SAIDI and SAIFI is the bench mark for reliability of electrical energy supply. The reliable of insulator cover type: YSL-70-AP affect to the reliability electrical distribution energy on over head distribution circuit. Insulator cover protected to over head distribution circuit againt animal, bird, tree ang other temporary disturbance. Insulator cover also to protect half insulated medium voltage cable againt partial discharge and flashover. Over voltage stress more often during operation, to impact to the material insulation performance. This quantitative research founding: insulator cover type: YSL-70-AP still feasible to use after voltage breakdown stress. The fault current is still under the maximum allowable leakage current (11,600 micro ampere) which is 41.61 micro ampere, and breakdown voltage is still higher than minimum that specified (24 kilo volt), which is 49.63 kilo volt. Post breakdown voltage the material insulation performance of insulator cover type: YSL-70-AP is good, and reliable to continuous operation over head distribution circuit.

Jaringan kolaborasi para penulis

6 penulis · 7 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Politeknik Negeri Bali
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
I Gede Suputra WidharmaAfiliasi tidak diketahui1
I Wayan TeresnaPoliteknik Negeri Bali1
Ida Bagus Prabha GirindraPoliteknik Negeri Bali1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ojs.pnb.ac.id/index.php/LOGIC/oai, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Performance Insulator Cover Type : YSL-70-AP Post Voltage Break Down Test</dc:title>
	<dc:creator>Jondra, Wayan</dc:creator>
	<dc:creator>Widharma, IGS</dc:creator>
	<dc:creator>Sunaya, Nengah</dc:creator>
	<dc:description xml:lang="en-US">Electrical energy affect to economic, electrical energy consumption will increase and decrease likely economics. In this globalization era, electricity consumption was increased trend yearly since industrialization era. The reliability Electrical energy is very important for economic growth. The lower SAIDI and SAIFI is the bench mark for reliability of electrical energy supply. The reliable of insulator cover type: YSL-70-AP affect to the reliability electrical distribution energy on over head distribution circuit. Insulator cover protected to over head distribution circuit againt animal, bird, tree ang other temporary disturbance. Insulator cover also to protect half insulated medium voltage cable againt partial discharge and flashover.&amp;nbsp;&amp;nbsp; Over voltage stress more often during operation, to impact to the material insulation performance. This quantitative research founding:&amp;nbsp; insulator cover type: YSL-70-AP still feasible to use after voltage breakdown stress. The fault current is still under the maximum allowable leakage current (11,600 micro ampere) which is 41.61 micro ampere, and breakdown voltage is still&amp;nbsp;&amp;nbsp; higher than minimum that specified (24 kilo volt), which is 49.63 kilo volt. Post breakdown voltage the material insulation performance of insulator cover type: YSL-70-AP is good, and reliable to continuous operation over head distribution circuit.</dc:description>
	<dc:publisher xml:lang="en-US">Pusat Penelitian dan Pengabdian kepada Masyarakat (P3M) Politeknik Negeri Bali</dc:publisher>
	<dc:date>2020-07-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ojs.pnb.ac.id/index.php/LOGIC/article/view/1784</dc:identifier>
	<dc:identifier>10.31940/logic.v20i2.1784</dc:identifier>
	<dc:source xml:lang="en-US">Logic : Jurnal Rancang Bangun dan Teknologi; Vol 20 No 2 (2020): July; 95-98</dc:source>
	<dc:source>2580-5649</dc:source>
	<dc:source>1412-114X</dc:source>
	<dc:source>10.31940/logic.v20i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ojs.pnb.ac.id/index.php/LOGIC/article/view/1784/1441</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2020 Logic : Jurnal Rancang Bangun dan Teknologi</dc:rights>