Melola Discovery

← Melola Discovery

Jurnal SINTA 3

The Performance of Irregular Building Structures Using Pushover Analysis

Logic: Jurnal Rancang Bangun dan Teknologi · Vol. 20 No. 2 (2020) · hlm. 65–72

DOI
10.31940/logic.v20i2.1456
ISSN
2580-5649, 1412-114X
Terbit
2020-07-30
Penerbit
Pusat Penelitian dan Pengabdian kepada Masyarakat (P3M) Politeknik Negeri Bali
Bahasa
eng

Abstrak

High-rise buildings are at risk of collapse due to the earthquake. One method for analyzing earthquake loads is Pushover. Pushover is a non-linear static analysis to determine the behavior of a building collapse. This research was conducted to determine the performance of the setback building with a soft first story due to the earthquake based on the results of the pushover analysis curve. The structure is modeled as a 2-dimensional portal with a form of structural irregularity (setback with the soft first story) which consists of 2 structural models with different setback area ratios. The results of the analysis of this study indicate that the maximum shear force based on capacity curves in type 1 and type 2 buildings are 50260549.81 N and 53560488.63 N. Buildings with smaller setback area ratios, i.e., type 2 buildings have displacement, story drift, and base shear are more significant than type 1 buildings. Performance of type 1 and Type 2 building structures that refer to ATC-40 and FEMA 356 is at the Damage Control level.

Jaringan kolaborasi para penulis

11 penulis · 20 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Jakarta State Polytechnic
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Jonathan SaputraJakarta State Polytechnic4
I Ketut SucitaJakarta State Polytechnic2
Jasun Widiana PutraJakarta State Polytechnic1
Hanif Satria AjiJakarta State Polytechnic1
Oky Bima PutraJakarta State Polytechnic1
Ilham Dwiputra RamadhanJakarta State Polytechnic1
Tree Irma DindaJakarta State Polytechnic1
Nadhila Ramadhani A.P.Jakarta State Polytechnic1
Annisaa Dina PuspitaJakarta State Polytechnic1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ojs.pnb.ac.id/index.php/LOGIC/oai, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">The Performance of Irregular Building   Structures Using Pushover Analysis</dc:title>
	<dc:creator>Yurizka, Hanan</dc:creator>
	<dc:creator>Rosyidah, Anis</dc:creator>
	<dc:description xml:lang="en-US">High-rise buildings are at risk of collapse due to the earthquake. One method for analyzing earthquake loads is Pushover. Pushover is a non-linear static analysis to determine the behavior of a building collapse. This research was conducted to determine the performance of the setback building with a soft first story due to the earthquake based on the results of the pushover analysis curve. The structure is modeled as a 2-dimensional portal with a form of structural irregularity (setback with the soft first story) which consists of 2 structural models with different setback area ratios. The results of the analysis of this study indicate that the maximum shear force based on capacity curves in type 1 and type 2 buildings are 50260549.81 N and 53560488.63 N. Buildings with smaller setback area ratios, i.e., type 2 buildings have displacement, story drift, and base shear are more significant than type 1 buildings. Performance of type 1 and Type 2 building structures that refer to ATC-40 and FEMA 356 is at the Damage Control level.</dc:description>
	<dc:publisher xml:lang="en-US">Pusat Penelitian dan Pengabdian kepada Masyarakat (P3M) Politeknik Negeri Bali</dc:publisher>
	<dc:date>2020-07-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ojs.pnb.ac.id/index.php/LOGIC/article/view/1456</dc:identifier>
	<dc:identifier>10.31940/logic.v20i2.1456</dc:identifier>
	<dc:source xml:lang="en-US">Logic : Jurnal Rancang Bangun dan Teknologi; Vol 20 No 2 (2020): July; 65-72</dc:source>
	<dc:source>2580-5649</dc:source>
	<dc:source>1412-114X</dc:source>
	<dc:source>10.31940/logic.v20i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ojs.pnb.ac.id/index.php/LOGIC/article/view/1456/1437</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2020 Logic : Jurnal Rancang Bangun dan Teknologi</dc:rights>
</oai_dc:dc>